Emerson SMMC-3 manual Sensor Extension Wire Specifications

Page 14

SPECIFICATIONS

Electrical

Mechanical

Power Requirements

NEMA 12 non-metallic enclosure

120 VAC, 50/60 hz, 480VA

 

Control Relays – Outputs

System Memory

120 VAC, Pilot Duty, 120VA

Non-Volatile: no data loss

Power Supply – Sensors

with a loss of system power

Dimensions

24 VAC, Class 3, 12VA

Temperature Sensor Supply

12.375” W x 10.25” H x 4.75” D

 

5 VDC, Class 2, 0.5VA

 

Certification

Environmental Specifications

Ambient Operating Temperature Range -4°F to 160°F / -20°C to 70°C

Storage Temperature

-4°F to 185°F / -20°C to 85°C

Relative Humidity

0 to 90% RH, non condensing

SENSOR EXTENSION WIRE SPECIFICATIONS

Aerial Sensor SMAS-1

3Conductor Instrumentation Cable, #18-20AWG, shielded or unshielded, common conductors such as twisted pair communications wire, telephone wire, electrical building wire and doorbell wire is not acceptable.

Manufacturer: Belden #8770 or equal

Gutter Sensor SMGS-1

3Conductor Instrumentation Cable, #18-20AWG, shielded or unshielded, common conductors such as twisted pair communications wire, telephone wire, electrical building wire and doorbell wire is not acceptable.

Manufacturer: Belden #8770 or equal

Temperature Sensor SMTS-1

3 Conductor Instrumentation Cable, #18AWG, unshielded, common conductors such as twisted pair communications wire, telephone wire, electrical building wire and doorbell wire is not acceptable.

Manufacturer: Belden #5301UE or equal

Pavement Sensor SMPS-1

4 Conductor Instrumentation Cable, #18AWG, shielded, common conductors such as twisted pair communications wire, telephone wire, electrical building wire and doorbell wire is not acceptable.

Manufacturer: Belden #9418 or equal

PO. Box 726 n TULSA, OK 74101 n TEL 918-627-5530 n FAX 918-641-7336 n www.nelsonheaters.com

GA-2318, R1

Sheet 14 of 15

May 2008

Image 14 Contents
SMMC-3 Manual Table of Contents GA-2318, R1 PRE-PROGRAMMED ConfigurationGeneral Information Installation Snow/ice sensor optionsPRE-PROGRAMMED Connections Connection to each sensor is described belowAfter energizing the controller, you should see System CheckBefore you energize the controller, confirm To cycle system and check sensor operationOperation Mode 1 IndependentMode 2 Priority Zone Assignment Time Delay Zone 1 min.0 2.0H Max.10Outside T=-3C A1-A2-A3-P1-P2-P3-M1 Manual OperationDegree C or F Mode No.1Mode No.2 2zones 3zones Ambient Off Temp. min.34 37F Max.50 Error Messages Manual only M1 Error!- SMTS-1 cancelError!- SMPS-1 Cancel Troubleshooting Guide Symptoms Probable Cause CorrectionGutter Sensor SMMC-3 Control Panel Access Cover RemovedTemperature Aerial Snow Sensor, SMTS-1 Sensor, SMAS-1 Specifications Sensor Extension Wire SpecificationsLimited Warranty and Liability