Fujitsu D2542 technical manual Screen resolution, Temperature / system monitoring

Page 19

Features

Screen resolution

3.4Screen resolution

Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board. If you are using an external screen controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the controller.

Screen resolution

Supported colors

 

 

640x480

8 bit, 16 bit, 24 bit, 32 bit

 

 

800x600

16 bit, 24 bit, 32 bit

 

 

1024x768

16 bit, 24 bit, 32 bit

 

 

1280x1024

8 bit, 16 bit

 

 

3.5Temperature / system monitoring

Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status.

The temperature and system monitoring are controlled by an onboard controller.

The following functions are supported:

Temperature monitoring

Measurement of the processor temperature, of the system board temperature, measurement of the ambient temperature by a temperature sensor.

Fan monitoring

Fans that are blocked or sticky are detected.

Fan control

The fans are regulated according to temperature.

D2542 (RX100 S5)

Technical Manual

19

Image 19
Contents System Board D2542 for RX100 S5 Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Contents Page Notational conventions IntroductionPage Important notes Batteries ESD label CE Certificate CE CertificateImportant notes Environmental ProtectionEnvironmentally friendly product design and development Returning, recycling and disposal Environmental ProtectionMain memory FeaturesOverview ProcessorsInternal connectors External connectorsOverview Form factor FeaturesBios features CSS Customer Self ServiceTPM Option Module population Main memoryPopulation of the memory Basic PCI bus PCI busPCI slots Temperature / system monitoring Screen resolutionSystem Event Log SEL Temperature / system monitoringSensor monitoring Voltage monitoringLEDs LEDsLED Indicator MeaningSchematic view of the system board D2542 Interfaces and connectorsExternal ports Interfaces and connectorsLAN connector LAN link/activity green LAN connectorsJP5 Password Skip Settings with jumpersSettings with jumpers JP8 Boot BlockReplacing the lithium battery Replacing the lithium batteryPage Abbreviations Abkürzungen IRMC Nvram RAM WfM