Operational

 

Depth of Field:

0" - 4"; 0"- 8" (programmable)

 

0 - 101.6mm; 0 - 203.2mm

Scan Speed:

1000 scan lines per second

Scan Pattern:

5 fields of 4 parallel lines

Scan Lines:

20

Min Bar Width:

5.2 mil

Indicators (LED):

red = laser on, ready to scan

 

green = good read, decoding

Beeper Operation:

3 tones or no beep

Maintenance:

Clean output window periodically

Decode Capability:

Autodiscriminates all standard bar codes;

 

for other symbologies call Metrologic

System Interfaces:

Keyboard Wedge, RS-232, OCIA, Light Pen, IBM

 

46xx

Print Contrast:

35% minimum reflectance difference

Roll, Pitch, Yaw:

360E, 60E, 60E

Environmental

 

Storage Temperature:

-40EC to 60EC (-40EF to 140EF)

Operating Temperature:

0EC to 35EC (32EF to 95EF)

Humidity:

5% to 95% relative humidity, non-condensing

Light Levels:

Up to 300 LUX

Ventilation:

None required

Shock:

1m. (40") drop

Contaminants:

Sealed to resist airborne particulate contaminants

This Metrologic product may be covered by one or more of the following U.S. patents:

5, 073,702, 5,115,333, 5, 216,232, 5,484,992, 5,525,789, 5,557,093, 5,591,953, 5,616,908.

Specifications subject to change without notice.

29

Image 33
Contents Metrologic INSTRUMENTS, INC USA Corporate Headquarters Europe LocationsTable of Contents Appendix B Appendix aAppendix C Appendix DIntroduction MCA Metrologic Connector Adaptor Mlpn MCA951 Scanner and AccessoriesQuick Start Operational Test Scanner Installation Powered by External Power Supply Scanner Installation Powered by Host Device Manufacturer’s Recommendation Complete Stand Kit Mlpn MS6720 StandGreen and Red LED Scanner PartsThree Beeps after power up Audible IndicatorsOne Beep Razzberry ToneFailure Modes Three Beeps on power upFlashing Red and One Razzberry Tone Flashing Red and Green and Two Razzberry TonesNo Red or Green LED Visual IndicatorsLabel Normal Depth of Field Depth of Field SpecificationsShort Depth of Field Extended Depth of Field Optional Depth of Field Normal Depth of Field Short Depth of Field Automatic Turn-On Specifications IR SensorOmnidirectional Scan Volume Scan Pattern SpecificsProjection Axis Cross-Sectional Scan Pattern Maintenance All Interfaces All Interfaces Possible CAUSES/SOLUTIONS Keyboard Wedge Only RS-232 only Scanner Version Identifier Communication Protocols Applications and ProtocolsKeyboard Type Keyboard Country TypeAppendix a Design SpecificationsMechanical ElectricalEnvironmental OperationalAppendix B Default SettingsDTS/NIXDORF NCR F NCR S ACK/NAK Ocia Pin Assignments Cable Pin Assignments for the Coil Cable Appendix CVersion 9 Ocia Version 11 Pin Function Version 14 Version 15 Ltpn FuPinction FunctionVersion 14 Version 15 Ltpn Pin Function FuPinction Pin Assignments for the MCA951 DEC9SPin Female DIN Pin FunctionPin Male DIN Pin Male mini-DIN Function Appendix D Warranty and Disclaimer Limited WarrantyDisclaimer Remarque Appendix EAnmerkung Patents Appendix FMCA IndexLtpn System interfaces