Appendix C
Pin Assignments
Cable Pin Assignments for the Coil Cable
The MS6720 scanners are terminated to a 10 position shielded modular connector. All of the coil cables (MLPN 44530) for the MS6720 scanner are terminated the same. The difference between versions is the end of the cable going into the scanner. This connector plugs into different “J” positions on various computer/interface boards. Since each computer/interface board is different, the output signals are different.
Version “9” (OCIA) | Version “11” (46XX) | ||
Pin | Function | Pin | Function |
1 | Power/Signal Ground | 1 | Power/Signal Ground |
2 | RDATA | 2 | |
3 | RDATA Return | 3 | |
4 | Clock In | 4 | RTS Output |
5 | Clock In Return | 5 | CTS Input |
6 | Clock Out | 6 | IBM 46XX Transmit |
7 | Clock Out Return | 7 | IBM 46XX Receive |
8 | No Connection | 8 | No Connection |
9 | +5 VDC Power to Scanner | 9 | +5 VDC Power to Scanner |
10 | OCIA Shield Ground | 10 | Shield Ground |
Version “14” (232) | Version “15” (LTPN) | ||
FuPinction | Pin | Function | |
1 | Power/Signal Ground | 1 | Power/Signal Ground |
2 | 2 | ||
3 | 3 | ||
4 | RTS Output | 4 | RTS Output |
5 | CTS Input | 5 | CTS Input |
6 | DTR Input | 6 | Light Pen Source +5V |
7 | DSR Output | 7 | Light Pen Data |
8 | No Connection | 8 | No Connection |
9 | +5 VDC Power to Scanner | 9 | +5 VDC Power to Scanner |
10 | Shield Ground | 10 | Shield Ground |
34