Icom IC-F51, IC-F50 service manual Software Adjustments Receiving, Convenient

Page 18

SOFTWARE ADJUSTMENTS (RECEIVING)

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

Need to adjust “S-METER ADJUSTMENT” after “RX SENSITIVITY ADJUSTMENT” is adjusted. Otherwise, “S-METER ADJUSTMENT” will not be adjusted properly.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

1

• Operating CH

: CH11

MAIN

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

 

 

• Connect a standard signal generator to

 

8 load to the multi connector

level

 

[BPF T1],

 

 

the antenna connector and set as:

 

through the JIG cable (*OPC-

 

 

[BPF T2]

 

 

Frequency

: 136.000 MHz

 

966).

 

 

 

 

 

Level

: 10 µV* (–87 dBm)

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT:

 

 

 

 

 

 

 

 

The BPF T1, BPF T2 can be adjusted automatically.

 

 

 

 

 

q-1: Set the cursor to “BPF ALL” on the adjustment program and then push [ENTER] key.

 

 

 

 

q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.

 

 

 

 

 

 

or

 

 

 

 

 

 

 

w-1: Set the cursor to one of BPF T1, T2 as desired.

 

 

 

 

 

w-2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

 

w-3: Repeat w-1 and w-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

S-METER

 

1

• Operating CH

: CH11

Push [ENTER] key on the connected computer keyboard to

[S-METER]

 

 

• Connect an SSG to the antenna con-

set “S6 level”.

 

 

 

 

 

nector and set as:

 

 

 

 

 

 

 

Frequency

: 136.000 MHz

 

 

 

 

 

 

 

Level

: 4.5 µV* (–94 dBm)

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Set an SSG as

:

Push [ENTER] key on the connected computer keyboard to

 

 

 

Level

: 0.25 µV* (–119 dBm)

set “S1 level”.

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

 

1

• Operating CH

: CH9

Front

Internal speaker

Set “SQL level” to

LEVEL

 

 

• Connect an SSG to the antenna con-

panel

 

close squelch.

[SQL]

 

 

nector and set as:

 

 

Then set “SQL level”

 

 

 

Frequency

: 155.000 MHz

 

 

 

 

 

 

 

at the point

where

 

 

 

Level

: 0.18 µV* (–122 dBm)

 

 

 

 

 

 

 

the audio

signals

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

just appears.

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

5 - 5

Image 18 Contents
VHF Transceiver Introduction Ordering PartsRepair Notes Table of Contents ‘ Transmitter Specifications‘ General ‘ ReceiverInside Views Main UnitFront Unit Removing the Front Unit Disassembly InstructionsRemoving the Chassis Unit Removing the Main UnitRF Circuit Main Unit Antenna Switching Circuit Main UnitReceiver Circuits 3 1ST Mixer and 1ST if Circuits Main UnitReceive Mute Circuits Main and Front Units Transmitter CircuitsAF Amplifier Circuit Main and Front Units Microphone Amplifier Circuit Front and Main UnitsModulation Circuit Main Unit DRIVE/POWER Amplifier CircuitsPLL Circuits APC Circuit Main UnitMain Unit Voltage Line Power Supply CircuitVCO Circuit Main Unit Front Unit Voltage LineCompounder Circuit Main Unit Other CircuitsPort Allocations Expander IC Front Unit IC410Mdio SEG1SCK Msck4 D/A Converter IC Main Unit IC6 Expander IC Main Unit IC12Preparation Screen Display Example Adjustment Frequency ListFrequency Adjustment Item CtcssPtte PTT MIC Mice ConnectionJIG Cable SP+Software Adjustments Transmitting Software Adjustments Receiving ConvenientConnector Board VR BoardFront Unit Main Unit IC9Varicap HVC375BTRF Themistor Ertjoep 473J Ceramic ECJ0EC1H0R5B Mechanical Parts and Disassembly Unitmm inch SEMI-CONDUCTOR Information Transistor and FET’SDiodes Board Layouts Main UnitTOP View Bottom View Q23Front Unit J402MC401 VHF B6034B VR BoardConnector Board MP701Section Block Diagram CPUVoltage Diagram 2SC4116BLTC7W66FK 11-3 VR / Connector Boards VR Board Icom America Inc 32, Kamiminami, Hirano-ku, Osaka, 547-0003, Japan
Related manuals
Manual 38 pages 15.56 Kb