Mustang Survival MD0450 22 manual Conversion CAP Removal, Repacking

Page 20

CONVERSION CAP REMOVAL

Once the conversion cap is removed, the MD3196 becomes an automatic inflation device. Firmly pull the conversion cap lanyard to remove the conversion cap (Fig.25).

NOTE:Do not pull inflation lanyard when removing conversion cap

FIGURE 25

To remove the conversion cap when packed, pull the conversion cap lanyard out from the opening of the cover of the LP’s right lobe. Visually confirm the conversion cap has been removed from the valve opening.

Place the conversion cap in the anti-chafing cover, in the front pocket, when not in use.

Repacking

IMPORTANT: Carefully read the entire Repacking instructions to achieve a properly packed Inflatable Vest with LIFTTM

If your Inflatable Vest with LIFTTM has been used and/or the hydrostatic inflator replaced, always inflate through the oral tube and check that it stays inflated at least overnight. With the dust cap in the top of the oral tube, gently squeeze the Inflatable Vest with LIFTTM until all air or gas has been expelled (Fig. 11). Do not wring or twist the Inflatable Vest with LIFTTM. Put the oral tube dust cap back in its stowed position on the oral tube (Fig. 26). Let the life jacket dry before packing.

17

MUSTANG SURVIVAL

Image 20
Contents Inflatable Vest With Lifttm Page Contents Introduction What is AN Inflatable PFD? Inflatable PFD so you know what to do in an emergencyInstructions for USE Component Inspection InstructionsReadiness Checklist Donning Instructions Inflation Important Ensure the chest buckle is fastened, when inflated Automatic Backup InflationOral Inflation In-water Adjustments Special Considerations for Automatic Devices Usage Below Freezing Re-arming Your PFDCap Dispose of the used inflator body TrashDo not turn CenterIndicator InletValve SingleConversion Instructions Completely unzip the right lobe zipper inflator sideOpening Conversion CAP Removal RepackingYour PFD p.11 Right LobeRight Lobe Page \FIGURE Tuck in the zipper tail, so it is not exposed Fig Lobe, it should sit under the cover Care and Maintenance Instructions Ii Ensure the manual beaded handle is accessibleCheck the following at the intervals listed below Before Each UseMustang Survival HOW and WHY to Test Your PFD Cleaning and StoringPut on the Inflatable Vest with Lifttm HOW do YOU Test Your PFD Using the Automatic INFLATOR?HOW do YOU Test Your PFD Using the Manual INFLATOR? HOW do YOU Test Your PFD Using the Oral INFLATOR? Wear Your PFD Be ableHypothermia How hypothermia affects most adultsLessen heat loss and increase your survival time Safety Accessories Do not Attach PFD’S to Your BoatWE Save Lives for a Living