Mustang Survival MD0450 22 manual Readiness Checklist

Page 7

RE-ARMING YOUR PFD (p. 11).

NOTE: The single point indicator must be green before proceeding.

2)Open the cover at wearer’s right-hand side of the chest and lay the device flat.

3)Ensure the oral-inflation dust cap is in the stowed position (Fig. 22).

4)Ensure the single point indicator is green and the beaded handle is attached to it’s Velcro tab; secure the zippers on the Inflatable Vest with LIFTTM (see Repacking, p. 17).

5)Ensure the date on the inflator is not five years or older (Fig. 2). If it is, replace the inflator (see Re-arming Your PFD, p. 11).

Readiness Checklist

Check your Inflatable Vest with LIFTTM and ensure all of the checkpoints listed below are true before each use.

Single point indicator is green.

Ensure the current date is not past the date on the inflator. If it is, replace the inflator (see Re-arming Your PFD, p. 11).

All zippers, Velcroand waist buckle are securely fastened. Inflatable Vest with LIFTTM is not twisted.

Oral-inflation dust cap is in the stowed position (Fig. 22).

Ensure the beaded handle is placed through the opening and is attached to the Velcro tab on the outside of the vest (Fig. 35).

No rips, tears or holes; all seams are securely sewn; and the fabric, straps and hardware are still strong.

Your Inflatable Vest with LIFTTM is ready for use if all boxes are checked.

NOTE: Contact your Mustang Dealer if you have any concerns about the readiness of your Inflatable Vest with LIFTTM.

Inflatable Vest with LIFTTM Owner’s Manual

4

Image 7
Contents Inflatable Vest With Lifttm Page Contents Introduction Inflatable PFD so you know what to do in an emergency What is AN Inflatable PFD?Component Inspection Instructions Instructions for USEReadiness Checklist Donning Instructions Inflation Automatic Backup Inflation Important Ensure the chest buckle is fastened, when inflatedOral Inflation In-water Adjustments Special Considerations for Automatic Devices Re-arming Your PFD Usage Below FreezingCap Center Dispose of the used inflator bodyTrash Do not turnSingle IndicatorInlet ValveCompletely unzip the right lobe zipper inflator side Conversion InstructionsOpening Repacking Conversion CAP RemovalRight Lobe Your PFD p.11Right Lobe Page \FIGURE Tuck in the zipper tail, so it is not exposed Fig Lobe, it should sit under the cover Before Each Use Care and Maintenance InstructionsIi Ensure the manual beaded handle is accessible Check the following at the intervals listed belowMustang Survival Cleaning and Storing HOW and WHY to Test Your PFDHOW do YOU Test Your PFD Using the Manual INFLATOR? HOW do YOU Test Your PFD Using the Automatic INFLATOR?Put on the Inflatable Vest with Lifttm HOW do YOU Test Your PFD Using the Oral INFLATOR? Be able Wear Your PFDHow hypothermia affects most adults HypothermiaLessen heat loss and increase your survival time Do not Attach PFD’S to Your Boat Safety AccessoriesWE Save Lives for a Living