Final Packing

1.Ensure the opening in the cover fabric is secured around the hydrostatic inflator. The water inlet valve should be easily accessible.

2.Secure the beaded handle to the LP cover using the snaps at the base of the unit.

Maintaining the LP

Before each use, review the Readiness Checklist – see Product Familiarization and Readiness.

NOTE: After each inflation, re-arm the MD1250 LP as soon as possible.

After each use, deflate, re-arm, and repack the LP – see:

Deflating the LP

Re-arming the LP

Repacking the LP

Prior to Use

Visually inspect the LP between outings:

Ensure the LP is properly armed.

Ensure the LP is free of rips, tears, or holes.

Ensure all seams on the LP are securely sewn.

Ensure the fabric, straps, and hardware on the LP are free from any defects.

CAUTION: To avoid accidental inflation, do not allow the manual/automatic hydrostatic inflator to submerge in water.

General Tests and Inspections

Record all inspections in permanent ink on the Inspection Record tag inside the LP (Figure 20).

After each test or inspection, repack the LP – see Repacking the LP.

Perform the following inspections annually, after each inflation, or whenever the integrity of the LP is in doubt.

Visually inspect all components for dirt or corrosion, and clean or replace as necessary.

Visually inspect the LP for damage or excessive abrasion, wear, fabric tears, or contamination. Particular attention must be paid to the stitching, straps, and hardware.

Visually inspect the status indicator on the hydrostatic inflator. Green indicates that the inflator is armed and ready for use. Red indicates that the inflator has been fired and must be replaced – see Re-arming the LP.

9

Tactical Inflatable Side Pouch LP Owners Manual

Image 12
Contents MD1250 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness Readiness Checklist Using an LE BeltUsing Integrated Pals Webbing and a Molle Vest Wearing the LPInflating the LP Manual InflationAuto-Inflation Oral InflationDonning the Inflated LP Converting the LPDeflating the LP Reversing the ConversionRe-arming the LP Repacking the LP Gas Removal from the Inflation CellResetting and Closing the Zippers Folding the Inflation CellMaintaining the LP Final PackingPrior to Use General Tests and InspectionsTesting for Leaks Testing the Oral Inflation ValveTesting the Manual Inflator Cleaning and Storing the LP Testing the Automatic InflatorAccessories GlossaryMail custserv@mustangsurvival.com Toll Free