Mustang Survival MD1250 manual Donning the Inflated LP, Converting the LP, Deflating the LP

Page 8

4.Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place.

Donning the Inflated LP

Figure 6

Once the LPs have been inflated through manual, automatic, or oral inflation, tuck the inflated cells underneath each arm (Figure 6).

Attach the left and right cells together using the Velcro® straps located at the front of each lobe.

Converting the LP

NOTE: A fully armed MD1250 LP with an MA7219 auto/manual conversion cap is required for this procedure.

Any time complete manual control of inflation is required, the LP can be converted from manual/automatic inflation to manual-only inflation by attaching the automatic/manual conversion cap.

The conversion can be reversed by removing the conversion cap.

1.Open the Velcro® cover over the hydrostaic inflator.

2.Remove the conversion cap from the elastic storage pocket.

3.Position the conversion cap

over the hydrostatic water Figure 7

inlet valve (Figure 7).

4. Secure the conversion cap

 

to the water inlet valve by

 

applying pressure to the

 

conversion cap at the metal

 

clip until it locks in place

Figure 8

(Figure 8).

 

Reversing the Conversion

To reverse the conversion:

1.Remove the conversion cap by pulling firmly on the lanyard.

2.Store the conversion cap in the elastic storage pocket.

Deflating the LP

1. Locate the oral inflation tube, and turn the locking

Figure 9

ring clockwise to open the inflator valve and unlock

 

the mouthpiece (Figure 9).

 

2.Press (and hold) the mouthpiece down.

3.Gently squeeze the inflation cell until fully deflated, ensuring all air or CO2 is removed.

5

Tactical Inflatable Side Pouch LP Owners Manual

Image 8
Contents MD1250 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness Readiness Checklist Using an LE BeltUsing Integrated Pals Webbing and a Molle Vest Wearing the LPInflating the LP Manual InflationAuto-Inflation Oral InflationDonning the Inflated LP Converting the LPDeflating the LP Reversing the ConversionRe-arming the LP Repacking the LP Gas Removal from the Inflation CellResetting and Closing the Zippers Folding the Inflation CellMaintaining the LP Final PackingPrior to Use General Tests and InspectionsTesting the Manual Inflator Testing for LeaksTesting the Oral Inflation Valve Cleaning and Storing the LP Testing the Automatic InflatorAccessories GlossaryMail custserv@mustangsurvival.com Toll Free