Mustang Survival MD1250 manual Introduction

Page 4

Introduction

This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 Tactical Inflatable Side Pouch Life Preservers (LPs).

The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs.

The MD1250 LP has been designed specifically for easy integration with law enforcement (LE) belts, and body armor and tactical vests, including integrated Pouch Attachment Ladder System (PALS) webbing and Modular Lightweight Load-carrying Equipment (MOLLE) vests.

The MD1250 LP inflates automatically on submersion using a manual/ automatic hydrostatic inflator that significantly reduces the potential for accidental inflation due to humidity, sea spray, or wet storage.

When the hydrostatic inflator is submerged in more than four inches in water the water inlet valve opens letting water contact the water-sensitive element. The water-sensitive element releases a stainless steel coil spring that drives a needle into the end of the CO2 cylinder, puncturing it and allowing CO2 to fill the inflation cell.

Each MD1250 LP can be inflated manually by pulling the beaded manual inflation handle. The LP may also be converted to manualonly operation with the included automatic/manual conversion cap.

Backup or topup manual inflation or buoyancy reduction can be accomplished using the oral inflator tube.

In-water performance tests with the MD1250 LPs attached to a typical body armor vest demonstrate the ability of the LPs to provide effective flotation and buoyancy.

Due to variances in local configuration, full gear in-water testing is strongly recommended to validate performance.

When worn, used, and serviced according to the instructions in this manual, Mustang Survival MD1250 Tactical Inflatable Side Pouch LPs can greatly increase a user's chance of survival in the water.

1

Tactical Inflatable Side Pouch LP Owners Manual

Image 4
Contents MD1250 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness Readiness Checklist Using an LE BeltUsing Integrated Pals Webbing and a Molle Vest Wearing the LPInflating the LP Manual InflationAuto-Inflation Oral InflationDonning the Inflated LP Converting the LPDeflating the LP Reversing the ConversionRe-arming the LP Repacking the LP Gas Removal from the Inflation CellResetting and Closing the Zippers Folding the Inflation CellMaintaining the LP Final PackingPrior to Use General Tests and InspectionsTesting the Oral Inflation Valve Testing for LeaksTesting the Manual Inflator Cleaning and Storing the LP Testing the Automatic InflatorAccessories GlossaryMail custserv@mustangsurvival.com Toll Free