Mustang Survival MD1250 manual Repacking the LP, Gas Removal from the Inflation Cell

Page 10

12.Ensure that the status indicator on the replacement inflator cap is green, the lanyard for the beaded manual inflation handle is present, and the locking ring is locked.

13.To test for leakage, inflate the LP using the oral inflator tube – see Inflating the LP. To avoid damage to the LP do not exceed 2 psi. After two hours there should be no noticeable drop in pressure in the LP.

Repacking the LP

NOTE: After each field-use inflation, the MD1250 LPs must be rearmed, leak tested, and fully deflated before repacking.

1.Visually inspect the status indicator on the hydrostatic inflator (Figure 13). Green indicates that the inflator is armed and ready for use. Red indicates that the inflator has been fired and must be replaced – see Re-arming the LP.

2.Visually inspect the expiry date on the hydrostatic inflator (Figure 13). If the expiry date has passed, replace the inflator – see Re-arming the LP.

Figure 13

 

Hydrostatic Water

 

Inlet Valve

 

Black Locking Ring

 

Tabs

Status

Manual In￿ation

Lanyard

Indicator

Beaded Manual

Expiry Date

In￿ation Handle

Gas Removal from the Inflation Cell

WARNING: All gas must be evacuated from the inflation cell prior to packing the LP. Failure to follow this procedure will significantly degrade the performance of the automatic inflation system.

1.A vacuum source capable of achieving at least 5 in-Hg and a vacuum fitting suitable to connect the vacuum source to the oral inflator is required to complete this procedure.

Note: A 3 HP shop vaccuum will provide more than 5 in-Hg of vaccuum.

2.Place the LP on a flat surface with the hydrostatic inflator facing upwards.

3.Attach the automatic/manual conversion cap (MA7219) to the hydrostatic inflator.

4.Turn the LP upside down so that the hydrostatic inflator is facing downwards.

5.Locate the oral inflation tube and turn the locking ring clockwise to open the inflator valve and unlock the mouthpiece.

6.Attach a vacuum fitting to the oral inflator.

7.Turn on the vacuum source.

8.Pinch the black flange at the base of the oral inflation tube. This will help prevent the bladder fabric from sealing off the vacuum.

9.Depress the mouthpiece to evacuate the entrapped gas from the inflation cell.

7

Tactical Inflatable Side Pouch LP Owners Manual

Image 10
Contents MD1250 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness Using Integrated Pals Webbing and a Molle Vest Readiness ChecklistUsing an LE Belt Wearing the LPAuto-Inflation Inflating the LPManual Inflation Oral InflationDeflating the LP Donning the Inflated LPConverting the LP Reversing the ConversionRe-arming the LP Repacking the LP Gas Removal from the Inflation CellResetting and Closing the Zippers Folding the Inflation CellPrior to Use Maintaining the LPFinal Packing General Tests and InspectionsTesting the Oral Inflation Valve Testing for LeaksTesting the Manual Inflator Cleaning and Storing the LP Testing the Automatic InflatorAccessories GlossaryMail custserv@mustangsurvival.com Toll Free