SUPER MICRO Computer 2022G-URF user manual

Page 104

A+ SERVER 2022G-URF User's Manual

Notes

7-16

Image 104
Contents Super Page Manual Organization PrefaceAbout This Manual Advanced Chassis Setup BiosContents System Interface Advanced Chassis Setup Appendix C System Specifications Chapter Introduction OverviewSerial ATA Serverboard FeaturesProcessors Memory Server Chassis Features Cooling System Front Control PanelBackplane AMD SR5670/SP5100 Chipset System Block Diagram Asia-Pacific Contacting Supermicro HeadquartersEurope Chapter Server Installation Preparing for SetupChoosing a Setup Location Unpacking the SystemPage Ambient Operating Temperature Rack Mounting ConsiderationsOutward Installing the System into a RackIdentifying the Sections of the Rack Rails Releasing Inner Rail from the Outer Rails Locking TabsReleasing the Inner Rail Installing The Inner Rails on the Chassis Installing the Inner RailsInstalling the Outer Rails on the Rack Installing the Outer RailsStandard Chassis Installation Installing the Chassis into a Rack FigureChecking the Components and Setup Checking the Serverboard SetupAccessing the inside of the System Accessing the Inside of the System Checking the Drive Bay Setup Providing PowerChecking the Drives Checking the AirflowPage Reset PowerChapter System Interface Control Panel ButtonsPower Fail Control Panel LEDsInformation LED Informational LED StatusNIC1 Drive Carrier LEDs Sata DrivesChapter Standardized Warning Statements for AC Systems About Standardized Warning Statementsהרהזא תורהצה ןונקת Bewaar Deze Instructies Installation Instructions 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。Circuit Breaker Power Disconnection Warning Page Equipment Installation 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可 されています。Restricted Area Battery Handling ةعناصلا ةمرشلا تاميلعحل اقفو ةلمعحسملا تايراطبلا نم صلخج Redundant Power Supplies Backplane Voltage Comply with Local and National Electrical Codes 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。Product Disposal 製品の廃棄Hot Swap Fan Warning ةحورمنا ةهتك يف تاحتفنا هع اديعب ءايشلأا هم اهريغو Power Cable and AC Adapter 電源コードとACアダプターPage Page Chapter Advanced Serverboard Setup Processor and Heatsink Installation Installing the ProcessorsTriangle Installing a Passive CPU Heatsink SNK-0043P HeatsinkConnecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control PanelFront Control Panel Header Pins JF1 I/O PortsTop View of DDR3 Slot Installing MemoryInstalling Memory Modules Memory Support Per Channel Dimm Populations OptionsPossible System Memory Allocation & Availability PCI Expansion Slots Installing a PCI Add-on CardAdding PCI Expansion Cards Serverboard Details Super H8DGU-F LayoutJumper Description Default Setting H8DGU-F Quick ReferenceConnector Definitions Power ConnectorsPwon Connector Reset ConnectorNMI Button Power On LEDOverheat/Fan Fail LED OH Universal Serial Bus Ports USB HeadersFan Headers Serial PortsUIO Power Connector SgpioPower LED/Speaker Chassis IntrusionOverheat LED ATX PS/2 Keyboard and PS/2 Mouse PortsLAN1/2 Ethernet Ports Compact Flash Card PWR ConnectorUnit Identifier Button Video Connector Trusted Platform Module HeaderJumper Settings Explanation of JumpersCmos Clear JBT1 Contact PadsWatch Dog Enable/Disable LAN1/2 Enable/DisableVGA Enable/Disable I2C to PCI-Express SlotOnboard Indicators Power LEDLAN1/LAN2 LEDs Dedicated Ipmi LAN LEDsSata Drive Connections Sata PortsInstalling the OS/SATA Driver Enabling Sata RAIDSerial ATA Sata Building a Driver DisketteEnabling Sata RAID in the Bios Bios Setup ScreenUsing the DotHill and Adaptec RAID Utility DotHill RAID Utility Program ScreenInstalling Software Installing the RAID Driver During OS InstallationSuperDoctor SuperDoctor III Interface Display Screen Health Information Serverboard Battery 11. Installing the Onboard BatteryPage USB Ports COM1 Port VGA Port Ethernet Ports Control PanelDrive Bays USB Ports 2 COM Port Slim DVD-ROM Drive System Fans System Fan FailureDrive Bay Installation/Removal Accessing the Drive BaysInstalling a New Fan Replacing System FansMounting a SAS/SATA Drive in a Drive Carrier SAS/SATA Drive InstallationInstalling/Removing Hot-swap SAS/SATA Drives Hard Drive Backplane Removing a SAS/SATA Drive Carrier Handle Release ButtonDVD-ROM Installation Accessing the Inside of the ChassisPower Supply Power Supply FailureRemoving/Replacing the Power Supply Removing the Power SupplyMain Menu ChapterIntroduction System Time/System Date Advanced Settings Menu Boot Feature  Processor and Clock Options  Advanced Chipset Control  NorthBridge Configuration Bank Swizzle Mode ECC ModeDram ECC Enable Dram Timing Config IDE Configuration  Primary/Secondary/Third/Fourth IDE Master/SlavePIO Mode DMA ModeIDE Detect Timeout Sec A.R.T PCI/PnP Configuration  SuperIO Device Configuration  Remote Access Configuration Hardware Health Configuration  Acpi Configuration  Ipmi Configuration Set LAN Configuration  View BMC System Event LogBMC Watch Dog Timer Action IP Address SourceIP Address Subnet Mask Event Log Configuration Security MenuBoot Menu  Boot Device PriorityRetry Boot Devices  Hard Disk DrivesExit Menu Page Appendix a Bios Error Beep Codes Amibios Error Beep CodesPage Appendix B Installing Windows Installing the Windows OS for a RAID SystemInstalling the Windows OS for a Non-RAID System Appendix C System Specifications BiosServerboard Regulatory Compliance