SUPER MICRO Computer 2022G-URF user manual Serverboard Details, Super H8DGU-F Layout

Page 61

Chapter 5: Advanced Serverboard Setup

5-7 Serverboard Details

Figure 5-4. SUPER H8DGU-F Layout

(not drawn to scale)

UIOP

UID

LE1

LAN2

JPL1

LAN1

VGA

FAN8

COM1

USB0/1 IPMI_LAN

KB/MOUSE

COM2

Winbond

 

IPMB

BMC

 

JPG1 JWD

JP2

T-SGPIO2T-SGPIO1

DP2

JBT1

JI2C2

JI2C1

BATTERY

PCI-E 2.0 x16 SLOT

 

PCI-E 2.0 x8 in x4 SLOT

P1

 

-DIMM1A

P1-DIMM1B

P1-DIMM2A

P1-DIMM2B

CPU2

P1-DIMM3A

P1-DIMM3B

P1-DIMM4A

P1-DIMM4B

P2-DIMM4B

P2-DIMM4A

P2-DIMM3B

P2-DIMM3A

CPU1

P2-DIMM2B

P2-DIMM2A

P2-DIMM1B

P2-DIMM1A

USB4/5

 

AMD

 

 

AMD

 

 

 

SR5670

 

 

SP5100

 

 

USB2/3

 

 

 

 

 

 

 

 

 

FAN6

 

 

 

 

JWF1

JOH1

USB6

SATA0

SATA2

SATA4

FAN5

JL1

SATA1

SATA3

SATA5

JD1

JF1

FAN4

FAN3

FAN2

 

 

JPW2

JPW1

 

 

JPW3

 

JPI2C

FAN1

FAN7

 

Notes:

Jumpers not indicated are for test purposes only.

When LE1 LED is on, the onboard power connection is on. Make sure to unplug the power cables before removing or installing components.

IPMI (Intelligent Platform Management Interface) 2.0 is supported by the H8DGU-F. For more information on IPMI configuration, refer to the Embedded BMC IPMI User Guide @http://www.supermicro.com/support/manuals/.

Warning

To provide adequate power to the add-on cards installed on the serverboard, please connect the UIOP PWR connector to the power supply for these cards to work properly.

5-11

Image 61
Contents Super Page About This Manual PrefaceManual Organization Bios Advanced Chassis SetupContents System Interface Advanced Chassis Setup Appendix C System Specifications Overview Chapter IntroductionProcessors Memory Serverboard FeaturesSerial ATA Server Chassis Features Backplane Front Control PanelCooling System AMD SR5670/SP5100 Chipset System Block Diagram Europe Contacting Supermicro HeadquartersAsia-Pacific Preparing for Setup Chapter Server InstallationChoosing a Setup Location Unpacking the SystemPage Rack Mounting Considerations Ambient Operating TemperatureIdentifying the Sections of the Rack Rails Installing the System into a RackOutward Releasing the Inner Rail Locking TabsReleasing Inner Rail from the Outer Rails Installing the Inner Rails Installing The Inner Rails on the ChassisInstalling the Outer Rails Installing the Outer Rails on the RackInstalling the Chassis into a Rack Figure Standard Chassis InstallationAccessing the inside of the System Checking the Serverboard SetupChecking the Components and Setup Accessing the Inside of the System Providing Power Checking the Drive Bay SetupChecking the Drives Checking the AirflowPage Power ResetChapter System Interface Control Panel ButtonsControl Panel LEDs Power FailInformation LED Informational LED StatusNIC1 Sata Drives Drive Carrier LEDsAbout Standardized Warning Statements Chapter Standardized Warning Statements for AC Systemsהרהזא תורהצה ןונקת Bewaar Deze Instructies 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。 Installation InstructionsCircuit Breaker Power Disconnection Warning Page 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可 されています。 Equipment InstallationRestricted Area Battery Handling ةعناصلا ةمرشلا تاميلعحل اقفو ةلمعحسملا تايراطبلا نم صلخج Redundant Power Supplies Backplane Voltage 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 Comply with Local and National Electrical Codes製品の廃棄 Product DisposalHot Swap Fan Warning ةحورمنا ةهتك يف تاحتفنا هع اديعب ءايشلأا هم اهريغو 電源コードとACアダプター Power Cable and AC AdapterPage Page Chapter Advanced Serverboard Setup Installing the Processors Processor and Heatsink InstallationTriangle SNK-0043P Heatsink Installing a Passive CPU HeatsinkConnecting Data Cables Connecting CablesConnecting Power Cables Connecting the Control PanelI/O Ports Front Control Panel Header Pins JF1Installing Memory Modules Installing MemoryTop View of DDR3 Slot Per Channel Dimm Populations Options Memory SupportPossible System Memory Allocation & Availability Adding PCI Expansion Cards Installing a PCI Add-on CardPCI Expansion Slots Super H8DGU-F Layout Serverboard DetailsH8DGU-F Quick Reference Jumper Description Default SettingPower Connectors Connector DefinitionsPwon Connector Reset ConnectorOverheat/Fan Fail LED OH Power On LEDNMI Button USB Headers Universal Serial Bus PortsFan Headers Serial PortsSgpio UIO Power ConnectorChassis Intrusion Power LED/SpeakerOverheat LED ATX PS/2 Keyboard and PS/2 Mouse PortsUnit Identifier Button Compact Flash Card PWR ConnectorLAN1/2 Ethernet Ports Trusted Platform Module Header Video ConnectorExplanation of Jumpers Jumper SettingsCmos Clear JBT1 Contact PadsLAN1/2 Enable/Disable Watch Dog Enable/DisableVGA Enable/Disable I2C to PCI-Express SlotPower LED Onboard IndicatorsLAN1/LAN2 LEDs Dedicated Ipmi LAN LEDsSata Ports Sata Drive ConnectionsEnabling Sata RAID Installing the OS/SATA DriverSerial ATA Sata Building a Driver DisketteBios Setup Screen Enabling Sata RAID in the BiosDotHill RAID Utility Program Screen Using the DotHill and Adaptec RAID UtilityInstalling the RAID Driver During OS Installation Installing SoftwareSuperDoctor SuperDoctor III Interface Display Screen Health Information 11. Installing the Onboard Battery Serverboard BatteryPage Drive Bays USB Ports 2 COM Port Slim DVD-ROM Drive Control PanelUSB Ports COM1 Port VGA Port Ethernet Ports System Fan Failure System FansAccessing the Drive Bays Drive Bay Installation/RemovalInstalling a New Fan Replacing System FansInstalling/Removing Hot-swap SAS/SATA Drives SAS/SATA Drive InstallationMounting a SAS/SATA Drive in a Drive Carrier Removing a SAS/SATA Drive Carrier Handle Release Button Hard Drive BackplaneAccessing the Inside of the Chassis DVD-ROM InstallationPower Supply Failure Power SupplyRemoving/Replacing the Power Supply Removing the Power SupplyIntroduction ChapterMain Menu  Boot Feature Advanced Settings MenuSystem Time/System Date  Processor and Clock Options  Advanced Chipset Control  NorthBridge Configuration ECC Mode Bank Swizzle ModeDram ECC Enable Dram Timing Config Primary/Secondary/Third/Fourth IDE Master/Slave  IDE ConfigurationDMA Mode PIO ModeIDE Detect Timeout Sec A.R.T PCI/PnP Configuration  Remote Access Configuration  SuperIO Device Configuration Hardware Health Configuration  Ipmi Configuration  Acpi Configuration Set LAN Configuration  View BMC System Event LogIP Address Source BMC Watch Dog Timer ActionIP Address Subnet MaskSecurity Menu  Event Log Configuration Boot Device Priority Boot MenuRetry Boot Devices  Hard Disk DrivesExit Menu Page Amibios Error Beep Codes Appendix a Bios Error Beep CodesPage Installing the Windows OS for a RAID System Appendix B Installing WindowsInstalling the Windows OS for a Non-RAID System Bios Appendix C System SpecificationsServerboard Regulatory Compliance