Simrad MN000802A-G manual Serial Connectivity

Page 11

The radar processor module connects to the various display heads using three different protocols. These are:-

Ethernet. For more information on connecting via Ethernet (see "Connect Simrad GB40 or Northstar 8000i" page 30)

GB40

8000i

Serial Connectivity

RS485 For more information how to connect to RS485 displays (see "Connect Simrad NX40 / NX45, Northstar M84 / M121" page 38)

NX40 / NX45

M Series

RS422. For more information how to connect to RS422 displays (see "Connect Northstar 6000i / 6100i" page 42)

6000i / 6100i

GlobalMap, LCX, LMS and X ranges of displays. See above list for specific models

Image 11
Contents KW Radar CE Compliance KW Radar Installation ManualFCC Statement Industry CanadaFeedback from you WarrantyContents Connect to Lowrance Displays MaintenanceConnect Simrad NX40 / NX45, Northstar M84 / M121 Connect Northstar 6000i13 2 kW radar system specifications Please Read Carefully Before USE PrefaceEthernet Connectivity Serial ConnectivityPage Branding information Introduction to the Navico radar systemBrand Display heads that support the Navico radar system 2 kw Radar overview Serial Connectivity Install the radar Dont do this Choose the scanner locationPower boat installations Scanner model Value half the -3 dB beam Width Yacht installationsHow to find the optimum height for the scanner How to find the theoretical maximum detection range 2 kW scanner dimensions How to reduce false echoes and shadow zonesInstall the 2 kW scanner unit Install a scanner on a trestleInstall the radar processor Check the 2 kW radar parts Page Page Wiring guidelines Page Page Page Yellow #24 White big #12 Shell Braid shield 2 kW radar processor connections Only Connect the power cableRadar system checklist Connect the ground wireEthernet Crossover cable Connect Simrad GB40 or NorthstarParts needed to connect radar to a GB40 or 8000i system Ethernet Cables Simrad GB40 and NorthstarAT10-HD Optional parts to connect GB40 onlyOptional parts to connect GB40 Simrad GB40 connection using SimNet heading Key Part Description Number Northstar 8000i / Simrad GB 40 using Nmea 0183 headingPage Pin Function Commision the radar using a GB40 or¾ tarting up Radar ¾ To correct ¾ Set Radar Range offset trigger Delay¾ Select OK to confirm the new setting ¾ To enter Radar setup optionsRadar information Radar Power on ActionRadar connection kit AA002461 Quanti Part name Connect Simrad NX40 / NX45, Northstar M84 / M121Parts needed NOR Connect the 2 kW radar processor to an M84 or M121 Display¾ Zero bearing Set up the radar with the Northstar M84 or M121¾ To enable the radar functionality ¾ Park position¾ Antenna height Serial comms extension cables + adaptor Quanti Part name Connect Northstar 6000iParts needed to connct to a Northstar 6000i Connect the 2 kW radar processor to a 6000i or 6100i display AUX NmeaPage Nmea 1 in B Remote Power OUT ShieldPower Nmea 1 in aPage ¾ Power on Option Turn the radar on ¾ Turn on the radar as follows¾ Turn the radar off Before you turn on the radar for the first timeAdjust the appearance settings Configure the navigator communicationsPrepare for calibration Disable the heading sensor inputHeading sensor requirements Calibrating the radar¾ To select a different curve Set the trigger delayTune the radar Set the STC CurvePress Page 2, Page 3, Page 4, and Install Set the heading calibration heading sensor installedPress Page 3, Page 4, and Install Restore the factory appearance settings Set the heading calibration heading sensor not installedRestore all the factory settings Press Sea Clutter Manual tuning procedure for the 6000i or 6100i system¾ Next, set the scale to 1/8 nautical miles as follows Heading Sensor Optional Quantit Part Name Connect to Lowrance DisplaysParts needed to connect to Lowrance displays RIM300 Radar Interface Module Quantit Part name10.2 RIM300 Setup the radar with Lowrance displays Setup the basics ¾ Trigger Delay Preparation Radar SetupMain Bang Suppression Trigger DelayAdjust Main Bang Suppression Before heading line adjustment After heading line adjustment Scanner maintenance MaintenanceGeneral maintenance Other maintenance items If the scanner fails to turn Technical support, service and repairsTroubleshoot the radar Radar is not operating correctlyConfirm the equipment installed How to reduce noise and interferenceMake sure the power is present and correctly wired Make Model Serial Number Software Version Are range rings displayed?DC input To 15.6 V DC DC 12 V system only 13 2 kW radar system specificationsKW scanner NS-RDR-1021MD KW Radar processor specifications