Place the internal locking nut over the end of the interconnection cable, then attach connectors B and C to the connectors (as shown in the figure).
The broken line shows the route for the interconnection cable.
Attach connector D to one of the screws close by to provide an Earth (as shown in the figure).
The wiring details for the connector ends (B, C, and D) are as follows:
2 kW interconnection cable (NS003101) connector ends
Pin | Color/Name | AWG size | B | C | D |
1 | Green (big) | #12 |
| 1 |
|
|
|
|
|
|
|
2 | Yellow (big) | #12 |
| 2 |
|
|
|
|
|
|
|
3 | Green (thin) | #24 | 7 |
|
|
|
|
|
|
|
|
4 | Clear Coax signal | #24 | 4 |
|
|
|
|
|
|
|
|
5 | Drain wire for 4 | #24 | 5 |
|
|
|
|
|
|
|
|
6 | Drain wire for 7 | #24 | 3 |
|
|
|
|
|
|
|
|
7 | Black Coax signal | #24 | 2 |
|
|
|
|
|
|
|
|
8 | White | #24 | 6 |
|
|
|
|
|
|
|
|