MX535 UAIS Transponder Unit
Technical & Installation Manual
___________________________________________________________________________________________________________________
3.3.2.5DGPS – DGNSS Channel 9
Field / Protocol information:
All fields are provided for further information; please refer to
3.3.2.6ALARM CIRCUIT
The AIS requires that an alarm output (relay) must be connected to an audible alarm device (MX420/AIS or MKD CDU) or the ship’s alarm system, if available.
3.4 Sensor Interface Definitions
All interface ports of MX535 Transponder comply with
Talker drive circuits
The maximum output current is Imax = 50mA on each port. The drive circuit meets the requirements of
Listener Receiver Circuits
Multiple listeners may be connected to a single talker. Optional termination resistors (120Ohm) for the input lines are provided in the
The input impedance is 30kOhm between A and B lines, disregarding the connection of termination resistors. The minimum input voltage is ±0.3V.
The listener's receiver circuit complies with
Electrical isolation
There are no direct electrical connections between the signal lines A and B.
The signal ground C must not be connected to the ship main ground or power line!
This isolation is in accordance with IEC 60945.
Maximum voltage on the bus
The maximum applied voltage between signal lines A and B and between either line and
ground C is in accordance with
Data transmission
Data is transmitted in serial asynchronous form in accordance with IEC
The following parameters are used:
•Baud rate 4800 (bits/s)
•Data bits 8 (D7 = 0), parity none
•Stop bits 1.
11