Furuno FA-100 manual How to attach connector N-P-8DFB

Page 8

How to attach the connector N-P-8DFB for cable 8D-FB-CV

Outer Sheath

Dimensions in millimeters.

Armor

Inner Sheath Shield

 

50

30

Cover with heat-shrink tubing and heat.

Remove outer sheath and armor by the dimensions shown left.

Expose inner sheath and shield by the dimensions shown left.

Cut off insulator and core by 10mm.

30

10

Clamp

Gasket Clamp

Nut

(reddish

 

brown)

 

Aluminum Foil

Trim shield here.

Insulator

Trim aluminum tape foil here.

Twist shield end.

Ship on clamp nut, gasket and clamp as shown left.

Fold back shield over clamp and trim.

Cut aluminum foil at four places, 90° from one another.

Fold back aluminum foil onto shield and trim.

1

5

Pin

Clamp Nut

Shell

Solder through the hole.

Expose the insulator by 1mm.

Expose the core by 5mm.

Slip the pin onto the conductor. Solder them together through the hole on the pin.

Insert the pin into the shell. Screw the clamp nut into the shell.

(Tighten by turning the clamp nut. Do not tighten by turning the shell.)

How to attach connector N-P-8DFB

2

Image 8 Contents
Uais Transponder 00080932513 Safety Instructions Table of Contents System Configuration GPS/VHFOptional supply Equipment ListsStandard supply Extending antenna cable MountingAntenna Unit How to attach connector N-P-8DFB VHF antenna Location Horizontal separation distance How to attach the plug M-P-7 3 GPS/VHF combined antennaMounting procedures Installing distributor unit DB-1 Transponder Unit Desktop mountingFlush mount kit B Type OP24-2 Code no Flush mountingFlush mount kit a Type OP24-1 Code no Junction Box MountingPower Supply option Pilot Plug optionWiring GPS/VHF Conbined Antenna GVA-100 Distributor unit DB-1Armor Cable fabrication ConnectionINPUT/OUTPUT Signal Inputs from SensorsInput/Output of AIS Signal TB1 in the junctionboxInput of Gyrocompass Signal Alarm Signal OutputLAN Input/Output Pilot PlugJumper Setting in the Junction Box Input/Output Sentences GngpgllcinChanging Ship’s Mains Specifications 100-115 VAC White BlackSetting and Adjustment Setting MMSI, IMO No., Name and Call SignPage Setting GPS Antenna Position and Ship’s Type SET Antenna POS windowPress the ENT key to return to the Init Setting sub-menu System Settings System Settings sub-menuPriority window Error message SET LAN IP Addr window This page is intentionally left blank Packing List CB-100-A、CB-100-A-HK GVA-100 工事材料表 PR-240-CE GP-1850,GP-1650,FA-100,GP-1640/F SC-60/120,GD/GP-280/680/380 20AG-X-9405 マスト取付金具 Page Page Page Page May 20 Page Jan Jan Page Page Page Page Page Hatai