SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (CONTINUED)

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.

Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the

circuit.

The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine operating requirements, machine voltage, total amperage load and serial num- ber.

To install the incoming power lines, open the control box. Install con- duit into the pre-punched holes in the back of the control box. Route power wires and connect to power block and grounding lug. Install the service wires (L1, L2, and L3 (3 phase only)) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug provided. Tighten the connections. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.

Incoming Power Connection

Terminal Block

Decal showing “L1”, “L2”, & “L3” (3 phase models only).

VOLTAGE CHECK: Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incom- ing power at the terminal block and ensure it corresponds to the voltage listed on the data plate. If not, contact a qualified ser- vice agency to examine the problem. Do not run the dishmachine if the voltage is too high or too low. Shut off the service break- er and mark it as being for the dishmachine. Advise all proper personnel of any problems and of the location of the service breaker. Replace the control box cover and tighten down the screws.

VENTILATION OF DISHMACHINE: The dishmachine should be located with provisions for venting into an adequate exhaust hood or ventilation system. This is essential to permit efficient removal of the condensation exhaust. Ensure that the exhaust system is acceptable in accordance with all applicable codes and standards.

NOTE: Any damage that is caused by steam or moisture due to improper ventilation is NOT covered under the warranty.

This units covered in this manual have the following exhaust requirements:

Load End:

200 CFM

Unload End:

400 CFM

The exhaust system must be sized to handle this volume for the dishmachine to operate as it was designed to.

ELECTRIC HEAT: The thermostats for the machines covered in this manual are factory set. They should not be adjusted except by an authorized service agent.

TS Series Conveyors Technical Manual 7610-002-98-29

Issued: 02-15-2006 Revised: N/A

19

Image 26
Contents Installation Manual for Export Units Technical ManualManufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN TS-44GP Nomenclature for the Models Covered in this ManualTable of Contents Electrical Schematics VII TroubleshootingSection Specification Information Specification Information Electrical Requirements TS-44/TSC-44 Dimensions Typical dimension of the auxillary rinse tank found on Wall TS-66/TSC-66 Left to Right Dimensions Gas-heated models TS-66/TSC-66 Right to Left Dimensions Specification Information Dishtable Dimensions TS/TSC-44 Dimensions TS/TSC-66 DimensionsSide Loader Left to Right Dimensions Section A-ASide Loader Right to Left Dimensions Roll Shield OpeningLeft to Right installation shown for reference Side Loader Installed Dimensions Side Loader DimensionsScrap Trough Dimensions Typical Electric and GAS Booster Dimensions Rear ViewSection Installation & Operation Instructions INSTALLATION/OPERATION Instructions Installation InstructionsIncoming Power Connection One of the extra openings in the back of the control box Deliming Operations Curtain Installation Diagrams Side Loader Installation & Operation Instructions Page Installation & Operation Instructions Detergent Control Installation Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Troubleshooting Common ProblemsTorque Settings Items Torque Spec
Related manuals
Manual 6 pages 57.62 Kb Manual 6 pages 10.77 Kb

TS-66G, TSC-66GPP, TSC-44GP, TS-44GP, TS-44 specifications

The Jackson TSC-66, TS-66, TSC-44, TS-44, and TS-44GP are a line of versatile, high-performance scorers designed to meet the diverse needs of any construction or road maintenance crew. Known for their reliability and exceptional build quality, these machines have become trusted tools in various applications, from road construction to surface maintenance.

Starting with the TSC-66, it stands as a powerful tool equipped with a robust engine that delivers high-performance results even under demanding conditions. The primary feature is its adjustable cutting depth, allowing operators to customize the depth of the cut based on the project requirements. Additionally, the TSC-66 comes with a user-friendly interface, featuring intuitive controls that enhance operational efficiency. The mobility of this model is another notable characteristic, thanks to its compact design and durable wheels, facilitating easy transport between job sites.

The TS-66 model shares many features with the TSC-66 but offers enhanced versatility with its multi-function capabilities. This machine can tackle various tasks beyond surface cutting, including grinding and finishing, which makes it an excellent choice for contractors specializing in diverse projects. Its high-torque motor is engineered for prolonged use, and its low-vibration technology ensures comfort during operation.

The TSC-44 and TS-44 models provide similar functionality with a focus on compactness and weight. These machines are perfect for smaller jobs and can easily navigate tight spaces. Equipped with advanced hydraulic systems, they feature superior lifting and cutting capabilities, allowing them to perform effectively in various conditions.

The TS-44GP variant is designed for general-purpose applications, combining the features of its peers with added emphasis on durability and ease of use. Its construction is particularly noteworthy, utilizing heavy-duty materials that ensure a long operational life. The incorporation of advanced safety features across all models underscores Jackson's commitment to user safety, with protective guards and emergency stop mechanisms built into the design.

In summary, the Jackson TSC-66, TS-66, TSC-44, TS-44, and TS-44GP models collectively represent a commitment to quality, performance, and versatility in the scoring equipment market. With their unique features, advanced technology, and durable construction, these machines are engineered to excel in a variety of demanding applications, making them a valuable addition to any contractor’s toolkit.