Xantrex Technology SW 1000, SW 600, SW 2000 manual Operating Limits, Power Output, Input Voltage

Page 27

Operation

Operating Limits

Power Output

The PROwatt SW Inverter will deliver the following power continuously, depending on input voltage and ambient temperature. The inverter will deliver more than 10% of its continuous power rating for approximately five minutes. The inverter must cool down for 15 minutes before it can resume operation above its continuous power rating.

 

 

Output

Input

Tempera

Model

Powera

Currentb

Voltage

ture

 

 

 

 

 

PROwatt SW 600

540 W

4.5 A

 

Ambient

 

 

 

 

PROwatt SW 1000

900 W

7.5 A

 

13 Vdc

25 °C

 

 

 

 

(77 °F)

PROwatt SW 2000

1800 W

15 A

 

 

 

 

 

 

 

 

a.Applies to resistive loads such as incandescent lights. b.Applies to reactive loads such as motors.

Input Voltage

The input voltage limits are shown in the following table.

Operating

 

 

Condition

Voltage Range

Comment

 

 

 

Normal

10.5–15.5 V

n/a

 

 

 

Peak Performance

13–14.5 V

n/a

 

 

 

Low Voltage Alarm

Voltage is

The audible low battery

 

11.0 V or less

alarm sounds.

 

 

 

Operating

 

 

Condition

Voltage Range

Comment

 

 

 

Low Voltage

Voltage is

The unit shuts down to

Shutdown

10.5 V or less.

protect the battery from

 

 

being over-discharged.

 

 

 

High Voltage

Voltage is

The unit shuts down to

Shutdown

15.5 V or more.

protect itself from

 

 

excessive input voltage.

 

 

Note: Although the

 

 

PROwatt SW Inverter

 

 

incorporates over-

 

 

voltage protection, it can

 

 

still be damaged if input

 

 

voltage exceeds 16 V.

 

 

 

Unit restarts after

11.5 V

The unit will not restart

low voltage

 

unless the battery

shutdown

 

voltage is acceptable for

 

 

running the load.

 

 

 

975-0529-01-01

17

Image 27
Contents Sine Wave Inverter Page Document Part Number About Xantrex TrademarksExclusion for Documentation Date and RevisionAbout This Guide Precautions When Working With Batteries Important Safety InstructionsXantrex PROwatt SW Sine Wave Inverter Owner’s Guide FCC Statement Page Contents Page PROwatt SW Inverter Series Quality PowerModel Continuous Surge Power IntroductionComprehensive Protection Ease of UseFeatures Optional AccessoryMaterials List Front Panel Details Feature DescriptionBack Panel Details FeatureTools and Materials InstallationBasic Installation Steps GuidelinesDetermine Battery Capacity Choose a LocationDetermine a Charging System Mount The Inverter Connect The Battery Cables Connect the Chassis GroundGrounding Locations For example Cabling GuidelinesModel ANL Fuse Class T Fuse/Circuit Breaker Sizing GuidelinesTotal Cold Cranking AmpsTo Other DC Loads Cabling ProcedureInstallation Installation GFCI-Protected AC Outlets OperationTurning the Inverter On and Off Operating Several Loads at OnceDigital Display Reading the Front Panel IndicatorsIndicator LEDs Restarting After an AC Output ShutdownPower Output Operating LimitsInput Voltage Exceptional Loads Battery Charging Frequency MaintenanceInverter Loads USB LoadsTroubleshooting Troubleshooting ReferenceCondition Possible Cause Solution Troubleshooting Physical and Environmental Specifications SpecificationsWarranty Warranty and Return InformationWarranty and Return Information Disclaimer ExclusionsProduct Return Procedure Return Material Authorization PolicyInformation About Your System Alarm sounding?Page Xantrex Technology Inc