Xantrex Technology 5000 manual Routine Maintenance, Recharging Your Batteries

Page 23

Routine Maintenance

Routine Maintenance

WARNING: Shock and energy hazard

Disconnect DC power before performing any routine maintenance work or before working on any circuits connected to the inverter.

Minimal maintenance is required to keep your inverter operating properly. Periodically you should:

Clean the exterior of the inverter with a damp cloth to prevent the accumulation of dust and dirt.

Ensure that the DC cables are secure and fasteners are tight.

Make sure ventilation openings on the AC and DC panels of the inverter are not obstructed by blankets and similar items and/or clogged with accumulated dust and dirt.

Recharging Your Batteries

When possible, recharge your batteries when they are about 50% discharged or earlier. This gives the batteries a much longer life cycle than recharging when they are more deeply discharged.

The XPower Inverter 5000 has a battery low voltage shutdown at 10.5Vdc. With moderate to heavy loads, this will protect against over- discharging the battery. If the inverter is running only light loads it is advisable to recharge before the inverter low voltage shutdown point is reached.

975-0376-01-01

3–5

Image 23
Contents XPower Inverter Date and Revision Audience About This GuidePurpose ScopeRelated Information OrganizationConventions Used Inverter Important Safety InstructionsPrecautions When Working With Batteries Precautions for Using Rechargeable Appliances Viii Contents Specifications TroubleshootingIntroduction Quality PowerComprehensive Protection Ease of UseFeatures Description AC PanelFeature Description DC Panel Battery NEG3Remote Switch Remote SwitchPage Turning the Inverter On and Off OperationDisplay Screen Operating Several Loads at OnceInput Voltage Power OutputOperating Limits Trouble Loads Inverter LoadsHigh Surge Loads Recharging Your Batteries Routine MaintenancePage Television Reception TroubleshootingCommon Problems Buzz in Audio EquipmentTroubleshooting Reference 975-0376-01-01 Troubleshooting Troubleshooting Reference 975-0376-01-01 Page Electrical Performance SpecificationsAccessory Physical SpecificationsWarranty Warranty and Return InformationDisclaimer Warranty and Return InformationExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty Service Purchased From Purchase Date Information About Your SystemWA-6