Xantrex Technology 5000 manual 975-0376-01-01

Page 27

 

 

 

 

 

Troubleshooting Reference

 

 

 

 

 

 

Table 4-1

Troubleshooting Reference

 

 

 

 

 

 

 

 

Error/Warning

 

 

 

#

Code on Display

Problem

Possible Cause

Solution

 

 

 

 

 

 

E03: Flashing

Inverter is in back-

The AC output is being

Check that no other source of

 

Fault LED:

EMF (backfeed)

supplied with back-EMF

electrical power is connected

 

Flashing

 

protection

(backfeed).

to the AC output circuits of

 

Alarm: Beeping

shutdown.

 

the inverter. If motor loads are

 

 

 

 

 

on the inverter, it is possible

 

 

 

 

 

that a motor shutdown caused

 

 

 

 

 

back-EMF (backfeed). If the

 

 

 

 

 

problem persists, the motor

 

 

 

 

 

may not be able to be operated

 

 

 

 

 

by this inverter.

 

 

 

 

 

4

E04: Flashing

Inverter is in

E07 warning code is

See solution under error # 7 in

 

Fault LED:

internal over

ignored. (See possible

this table.

 

Flashing

 

temperature

causes under error # 8 in

 

 

Alarm: Beeping

shutdown.

this table).

 

 

 

 

 

 

5

E05: Flashing

Inverter's Input

Poor battery condition

Charge the battery.

 

Fault LED:

Under Voltage

 

Install a new battery.

 

Flashing

 

Warning Alarm is

 

Use proper cable size and

 

Alarm: Beeping

on.

Poor DC wiring

 

 

 

 

 

lengths and make solid

 

 

 

 

 

connections.

 

 

 

 

 

For more information, refer to

 

 

 

 

 

“Selecting Cable Sizes”

 

 

 

 

 

starting on page 2-6 of the

 

 

 

 

 

Installation Guide.

 

 

 

 

 

6

E06: Flashing

Inverter's output

Load applied is above

Reduce the load if continuous

 

Fault LED:

overload warning

the continuous operation

operation is required.

 

Flashing

 

alarm is on.

limit.

 

 

Alarm: Beeping

 

 

 

 

 

 

 

 

7

E07: Flashing

Internal over

Inverter ventilation

Improve ventilation.

 

Fault LED:

temperature

openings are obstructed.

Make sure the inverter’s

 

Flashing

 

warning alarm is

 

ventilation openings are not

 

Alarm: Beeping

on.

 

obstructed.

 

 

 

 

Ambient temperature is

Reduce the ambient

 

 

 

 

too high.

temperature.

 

 

 

 

Load applied is above

Reduce the load if continuous

 

 

 

 

the continuous operation

operation is required.

 

 

 

 

limit.

 

 

 

 

 

 

 

975-0376-01-01

4–3

Image 27
Contents XPower Inverter Date and Revision Audience About This GuidePurpose ScopeOrganization Conventions UsedRelated Information Inverter Important Safety InstructionsPrecautions When Working With Batteries Precautions for Using Rechargeable Appliances Viii Contents Specifications TroubleshootingIntroduction Quality PowerComprehensive Protection Ease of UseFeatures Description AC PanelFeature Description DC Panel Battery NEG3Remote Switch Remote SwitchPage Turning the Inverter On and Off OperationDisplay Screen Operating Several Loads at OncePower Output Operating LimitsInput Voltage Inverter Loads High Surge LoadsTrouble Loads Recharging Your Batteries Routine MaintenancePage Television Reception TroubleshootingCommon Problems Buzz in Audio EquipmentTroubleshooting Reference 975-0376-01-01 Troubleshooting Troubleshooting Reference 975-0376-01-01 Page Electrical Performance SpecificationsAccessory Physical SpecificationsWarranty Warranty and Return InformationDisclaimer Warranty and Return InformationReturn Material Authorization Policy Return ProcedureExclusions Out of Warranty Service Purchased From Purchase Date Information About Your SystemWA-6