Graco G250HR, G3000HR, g250 important safety instructions Cleaning or Servicing the Meter Chamber

Page 10

Maintenance

Cleaning or Servicing the Meter Chamber

NOTICE

Clean and service the meter at a clean workbench. Use only lint-free cloth on parts.

Installing and servicing this equipment requires access to parts that may cause electric shock or other serious injury if the work is not performed properly. Do not install or service this equipment unless you are trained and qualified.

Use only genuine Graco replacement parts. Substitu- tion of components may impair intrinsic safety. This could result in a failure which causes serious injury and/or substantial property damage.

1.Follow the Pressure Relief Procedure, on page 7. Then close the fluid shut-off valve on each side of the meter.

2.Disconnect the cable from the electronic sensor device.

3.Disconnect both fluid line fittings and remove the meter from the fluid line.

4.Loosen the two screws and remove the electronic sensor device from the flow meter upper housing. See the Parts drawings, pages 12-14.

5.Loosen the screws. Keep a few threads of two opposing bolts engaged to minimize the torque stress on the shafts when you separate the meter housings.

6.Hold onto the upper housing and gently tap the opposing bolts to separate the lower housing.

NOTICE

To avoid damaging the shafts, keep the housings par- allel to each other when separating them; do not rock the housings from side to side. Do not use chisels or screwdrivers to split and pry apart the housings.

7.Remove and inspect the gears and shafts. Clean the meter parts with solvent.

8.Reassemble the gears and shafts into the lower housing in the position they were removed from. Check the gears for free and easy rotation.

9.Make sure the two locating pins are in place.

10.Assemble the two meter housings, making sure to keep them parallel to each other.

11.Install the screws. Tighten them oppositely and evenly, to 12 ft-lb (16 N•m). Do not over-tighten.

12.After re-assembling the meter, test the gear rotation by applying a brief air blast to the meter inlet. You should clearly hear the gears spin.

13.Set the electronic sensor on the upper housing and tighten the two screws hand-tight, about 3.5 ft-lb (4.7 N•m). Do not over-tighten.

10

308778L

Image 10
Contents Volumetric Fluid Flow Meter Important Safety InstructionsContents ModelsSkin Injection Hazard Equipment Misuse Hazard Installing the Flow Meter InstallationDust and Foreign Matter Grounding Flow Meter Function Pressure Relief Procedure Flow Volume RangeOperation Recommended UsageTroubleshooting Problem Cause SolutionResidue Build-up on the Meter Gears MaintenanceFlushing Cleaning or Servicing the Meter Chamber Flow Meter Kits, for ProMix 2KS Wall Fluid Panel Parts15V804 G3000 Meter Kit 15V827 G3000HR Meter Kit Bare Meter Assemblies Screw239716 G3000 Meter 244292 G3000HR Meter 249426 G250 Meter 249427 G250HR Meter G3000 and G3000HR DimensionsG250 and G250HR Technical Data Pressure Drop Curve Graco Standard Warranty Graco Information