Graco g250, G3000HR, G250HR important safety instructions Skin Injection Hazard

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SPECIAL CONDITIONS

Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire, explosion, or electric shock:

Never use the flow meter with an electrostatic gun isolation stand.

Keep liquids away from the electronic sensor device.

Do not service the electronic sensor. Return it to your Graco distributor for service.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

308778L

3

Image 3
Contents Important Safety Instructions Volumetric Fluid Flow MeterModels ContentsSkin Injection Hazard Equipment Misuse Hazard Installation Installing the Flow MeterDust and Foreign Matter Grounding Recommended Usage Pressure Relief Procedure Flow Volume RangeOperation Flow Meter FunctionProblem Cause Solution TroubleshootingMaintenance Residue Build-up on the Meter GearsFlushing Cleaning or Servicing the Meter Chamber Parts Flow Meter Kits, for ProMix 2KS Wall Fluid Panel15V804 G3000 Meter Kit 15V827 G3000HR Meter Kit Screw Bare Meter Assemblies239716 G3000 Meter 244292 G3000HR Meter 249426 G250 Meter 249427 G250HR Meter Dimensions G3000 and G3000HRG250 and G250HR Technical Data Pressure Drop Curve Graco Information Graco Standard Warranty