Technical Data
Technical Data
Maximum Fluid Working Pressure |
|
G3000 and G3000HR | 4000 psi (28 MPa, 276 bar) |
G250 and G250HR | 250 psi (1.72 MPa, 17.2 bar) |
|
|
Flow Range |
|
G3000 and G250 | |
G3000HR and G250HR | |
|
|
Fluid Temperature Range | |
|
|
Maximum Ambient Temperature | 180°F (80°C) |
Fluid Viscosity Range | |
Maximum Cable Length | 200 ft (61 m) |
|
|
Flow Meter Inlet/Outlet | 1/4 npt(f) |
Resolution |
|
G3000 and G250 | 0.119 cc/pulse |
G3000HR and G250HR | 0.061 cc/pulse |
|
|
Accuracy | +/- 0.5%* |
|
|
Supply Voltage | |
Intrinsic Safety | Class I; Div. 1; Group D |
| V max = 30 V |
| I max = 15 mA |
| Ci = 0.2 microfarads |
| Li = 0 mH |
|
|
Approvals | See front cover |
|
|
Wetted Parts | 303 Stainless Steel, Tungsten Carbide, PTFE |
Weight |
|
G3000 and G3000HR | 6 lb (2.7 kg) |
G250 and G250HR | 2.6 lb (1.8 kg) |
|
|
*For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.5%. Accuracy will dimin- ish at low viscosities and low flow rates.
16 | 308778L |