Graco 238892, 238894, 238890 important safety instructions Replacing the Fluid Diaphragms

Page 12

Service

Replacing the Fluid Diaphragms

See Fig. 3, and follow the steps below. For parts that are not called out in Fig. 3, see the Parts Drawing on page 14.

1.Relieve the pressure, and remove the regulator from the fluid line.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

2.Turn the adjusting screw (10) counterclockwise until it is loose to fully relieve the spring tension.

3.Remove the four base housing screws (9) from the base housing (4), and pull the base housing free of the backing plate (8).

4.Remove the diaphragm and valve actuator subassembly (1, 7, 12, 13, and 19).

5.Clean and inspect the bore in the backing plate (8) for wear, and replace it if necessary.

10

6.Remove the o-ring (17) from the groove in the base housing (4), clean and inspect the base housing, and replace if necessary.

7.Install a new o-ring (17) in the groove in the base housing (4).

8.Lightly lubricate the backing plate (8) bore and plunger (7) with a lithium-based grease.

9.Install the new, pre-assembled diaphragm subassembly into the backing plate (8).

NOTE: The diaphragms will have a bow in them before you install them.

10.Align the holes in the diaphragms with the backing plate (8).

11.Install the backing plate/diaphragms assembly over the base housing (4). Hold the backing plate

(8)tightly against the base housing, and install the four base housing screws (9).

12.Torque the base housing screws (9) first to 20 to 25 ft-lb (27 to 34 NSm), then to 30 to 35 ft-lb (41 to 48 NSm) in the sequence shown in Fig. 3.

2

Torque Sequence for Regulator

17Base Housing Screws (9)

41

4

backing plate (8)

diaphragm and valve actuator subassembly

cartridge assembly

3

5

23

Fig. 3

9

06656

12 308647

Image 12
Contents Instructions-Parts List Important Safety InstructionsModel 238892 Table of Contents List of ModelsSymbols Equipment Misuse HazardSkin Injection Hazard 308647 Installation Pressure Relief Procedure Grounding the SystemAdjusting the System Pressure Cleaning the RegulatorOperation Flushing Troubleshooting Problem Cause SolutionService Service KitsInstalling the Air-Operated Conversion Kit Relieve the pressureReplacing the Fluid Diaphragms Replacing the Cartridge Parts Drawing With EZ Flush gauge port plug With fluid pressure gaugeParts List Description QtyModels 238893, 238894, 248090, For Models 238894 238893 Model With EZ Flush gauge port plugRegulator Housing Technical Data Performance Chart KeyTest Conditions Page Dimensional Drawings Model 244734 air operatedGraco Standard Warranty Graco InformationToll Free