Graco 238890, 238892 Parts Drawing, With EZ Flush gauge port plug With fluid pressure gauge

Page 14

Parts Drawing

Models 238889, 238890, 238891, and 238892

238889 with EZ Flush gauge port plug

238890 with fluid pressure gauge

Spring-Operated Regulator

500 to 3000 psi (3.4 to 21 MPa, 34 to 207 bar) Regulated Fluid Outlet Pressure

6 10

32

627

611

6

8

DETAIL

Torque Sequence for Regulator

Base Housing Screws (9)

41

23

238891 with EZ Flush gauge port plug

238892 with fluid pressure gauge

Spring-Operated Regulator

3000 to 5000 psi (21 to 34 MPa, 207 to 345 bar) Regulated Fluid Outlet Pressure

7*

6

12*

 

13*

 

19*

1*

1

17*

29

30

4

 

 

 

 

 

3{ 2

 

 

14{

 

 

15{

28

5 9

20{ 7

18{ 7

16{

21{

5{ 4

06289

1Torque to 25 to 30 in-lb (2.8 to 3.4 NSm).

2Torque to 140 to 160 in-lb (16 to 18 NSm).

3Torque to 10 to 20 ft-lb (14 to 27 NSm).

4Torque to 30 to 35 ft-lb (41 to 48 NSm).

5Torque first to 20 to 25 ft-lb (27 to 34 NSm), then to 30 to 35 ft-lb (41 to 48 NSm) in the sequence shown in DETAIL at left.

6Apply lithium-based grease when reassembling.

7Apply a fluid-compatible grease to aid in reassembly.

14 308647

Image 14
Contents Model 238892 Instructions-Parts ListImportant Safety Instructions Table of Contents List of ModelsSymbols Equipment Misuse HazardSkin Injection Hazard 308647 Installation Pressure Relief Procedure Grounding the SystemOperation Adjusting the System PressureCleaning the Regulator Flushing Troubleshooting Problem Cause SolutionInstalling the Air-Operated Conversion Kit ServiceService Kits Relieve the pressureReplacing the Fluid Diaphragms Replacing the Cartridge Parts Drawing With EZ Flush gauge port plug With fluid pressure gaugeParts List Description QtyModels 238893, 238894, 248090, For Models 238894 238893 Model With EZ Flush gauge port plugRegulator Housing Technical Data Test Conditions Performance ChartKey Page Dimensional Drawings Model 244734 air operatedToll Free Graco Standard WarrantyGraco Information