OEM Systems Control Valve Function and Cycles of Operation, WS1EI & WS1.25EI Manual

Page 4
Control Valve Function and Cycles of Operation • Page 1

Control Valve Function and Cycles of Operation • Page 1

WS1EI & WS1.25EI Manual

Control Valve Function and Cycles of Operation

This glass filled Noryl1 (or equivalent) fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or filter. The WS1EI and WS1.25EI control valves are only available in downflow regeneration. When the WS1EI or WS1.25EI control valve is set up as a filter, the control valve can be set to perform downflow regeneration or simply backwash. The control valve can be set to regenerate on demand (consumption of a predetermined amount of water) and/or as a time clock (passage of a particular number of days). The control valve can be set so that a softener can meet the Water Quality Association (WQA) Standard S100 or NSF/ANSI Standard 44 efficiency rating.

The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the flow of water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the flow of brine or other regenerants. The control valve regulates the flow rates for backwashing, rinsing, and the replenishing of treated water into a regenerant tank, when applicable.

The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps, nuts and snap type latches are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to service the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is available which eliminates the need for screwdrivers and pliers. Disassembly for servicing takes much less time than comparable products currently on the market.

Control valve installation is made easy because the distributor tube can be cut 12.7 mm (½”) above to 12.7 mm (½”) below the top of tank thread. The distributor tube is held in place by an o-ring seal and the control valve also has a bayonet lock feature for upper distributor baskets.

The AC adapter power pack comes with a 4.6 meter (15 foot) power cord and is designed for use with the control valve. The AC adapter power pack is for dry location use only.

Table 1 shows the order of the cycles and available time for the WS1EI or WS1.25EI control valve. The WS1EI and WS1.25EI can be used for downflow softener and filter applications as well as backwash-only filters.

Table 1

Regeneration Cycles and Times

WS1EI & WS1.25EI Cycles of Operation

Cycle

Range of times (min.)

1.

Backwash 1st (upflow)

1 - 20 or OFF

2.

Regenerant Draw/Slow Rinse (downflow)

1 - 99 or OFF

3.

Backwash 2nd (upflow)

1 - 20 or OFF

4.

Fast Rinse (downflow)

1 - 20 or OFF

5.

Regenerant Refill (with treated water)

0.1 - 99.9 or OFF

6.

Service (downflow)

 

 

 

 

1Noryl is a trademark of General Electric.

Image 4
Contents 1.25” Control Valve Series Model WS1.25EI Water Specialist 1” Control Valve Series Model WS1EIOperation and Instruction Manual for OEM Only Page Table of Contents The common manual contains the Table of Contents shown belowWS1EI & WS1.25EI Manual INFORMATION MANUALControl Valve Function and Cycles of Operation Page Control Valve Function and Cycles of OperationRegeneration Cycles and Times The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately EI Front Cover and Drive Assembly Drawings and Part Numbers Page 2a Black PlugDrawings and Part Numbers Page 2b Grey Plug on all WS1.25 bodies Grey RingGrey Distributor O-ring retainer Only for valves that have a 32mm Distributor Tube OpeningDrawings and Part Numbers Page 2c WS1 & WS1.25 Identification FigureWS1 with 1.050 Distributor Tube Opening Identification WS1.25 with 1.32 Distributor Tube Opening IdentificationWS1EI & WS1.25EI Manual WS1EI & WS1.25EI Manual Revision History DRAWINGS AND PART NUMBERS PAGEForm No. V3115EI - Updated 11/12/07 11/12/07