Emerson 986269, LARGE AC ELECTRIC MOTORS manual Normal Operation, VIII. Doweling

Page 15

U.S. ELECTRICAL MOTORS INSTALLATION AND MAINTENANCE

Normal Operation

& Doweling

2.Inspection & Cleaning

Stop the motor before cleaning. (

CAUTION: See section on safety, page i). Clean the motor,

inside and outside, regularly. The frequency depends upon actual conditions existing around the motor. Use the following procedures, as they apply:

A.Wipe any contaminants from external surfaces of the motor.

B.Remove dirt, dust, or debris from ventilating air inlets. Use compressed air as necessary. Never allow dirt to accumulate near air inlets. Never operate motor with air passages blocked or restricted. For stubborn dirt n tubes of Totally-Enclosed-Tube-Cooled Motors, use a Tool Similar to a shotgun "ramrod".

CAUTION

When using compressed air, always use proper eye protection to prevent accidental eye injury.

C.Filters in weather protected top hats should be removed and cleaned per filter manufacturer's recommendations.

D.Clean motors internally by vacuuming or blowing with clean, dry compressed air. Generally a pressure not exceeding 30 PSI is recommended.

E.When dirt and dust are solidly packed, or windings are coated with oil or greasy grime, disassemble the motor and clean with solvent. Use only high-flash naphtha, mineral spirits, or Stoddard solvent. Wipe with solvent-dampened cloth, or use suitable soft bristle brush. DO NOT SOAK. Oven dry (150 - 175°F) solvent cleaned windings thoroughly before reassembly.

F.After cleaning and drying the windings, check the insulation resistance. Refer to Section III, Part 3 for procedure.

VIII. DOWELING

Doweling the motor (and driven unit) accomplishes the following:

1.Restricts movement of the motor and driven unit.

2.Eases realignment if motor is removed from base.

3.Temporarily restrains the motor, should mounting bolts loosen.

The following procedure for inserting dowel pins is recommended (See Figure 5).

1.Check the alignment after the unit has been in operation approximately one week. Correct if necessary.

2.Drill through motor feet on drive end and into base. Drill diameter must be slightly smaller than the intended dowel size to allow for reaming operation.

3.Ream holes in the feet and base to the proper diameter for the pins (light press fit). Clean out the chips.

4.Insert dowel pins.

10

Image 15
Contents Titan Page Safety First SafetyTable of Contents Page II. Handling ShipmentIII. Storage StorageStorage Storage Grouting Installation Location FoundationInstallation Location FoundationInitial Installation Initial InstallationFlexible Couplings Angular MisalignmentParallel Alignment Operated uncoupled from driven equipment Speed, RPM Normal OperationNO-LOAD Vibration Limits Velocity, Inches per secondDoweling Normal OperationVIII. Doweling Disassembly Reassembly IX. DisassemblyReassembly Dowel PIN Holes XI. Lubrication LubricationManufacturer Description Electrical Motors Fastener Size Torque* Ft.- Lbs Renewal Parts ServiceXII. Renewal Parts and Service Recommended Fastener Torque ValuesXIII. Cutawaydrawings Cutaway DrawingsXIV Troubleshooting Possible Cause Correction TroubleshootingTrouble Possible Cause Correction Record Installation Record

986269, LARGE AC ELECTRIC MOTORS specifications

Emerson Large AC Electric Motors, specifically model 986269, exemplify cutting-edge technology and exceptional design, catering to the diverse needs of industrial applications. These motors are engineered for reliability, efficiency, and performance, making them suitable for various sectors, including manufacturing, mining, and oil and gas.

One of the standout features of the Emerson 986269 motor is its robust construction. Built to withstand harsh operational environments, this motor has a durable housing that protects it from external contaminants such as dust, moisture, and chemicals, thereby prolonging its lifespan. The design promotes efficient heat dissipation, which minimizes overheating risks and enhances both performance and reliability.

Energy efficiency is a critical aspect of the Emerson 986269 AC electric motor. Utilizing advanced design methodologies, the motor offers high efficiency ratings, which translates into lower operational costs and reduced carbon footprints. It meets or exceeds the latest efficiency standards, making it an eco-friendly choice while ensuring optimal performance in various applications.

Another significant feature is its versatility. The Emerson 986269 motor is available in various sizes and configurations, making it suitable for different tasks and load requirements. Its adaptability allows seamless integration into existing systems, making it a valuable asset for businesses looking to upgrade their machinery without extensive modifications.

The motor employs state-of-the-art technologies such as premium-quality bearings and insulation systems, contributing to its quiet operation and minimal maintenance requirements. This means reduced downtime and increased productivity, both vital for maintaining competitive advantages in today's fast-paced industrial landscape.

Moreover, Emerson's commitment to safety is reflected in the design of the 986269 motor. It is equipped with advanced thermal protection features and complies with international safety standards, ensuring secure operation even in challenging conditions.

In conclusion, the Emerson Large AC Electric Motor 986269 sets the benchmark for performance, reliability, and efficiency in industrial applications. With its robust construction, energy-efficient design, and advanced technologies, it is an investment that promises long-term operational benefits and peace of mind for users. Whether for heavy-duty tasks or general industrial use, this motor remains a top choice for companies aiming to enhance their operational efficiency and productivity.