Furuno CSH-23F/24F manual Range R Auto Tilt Auto Scan Gain Brill TVG TVG DIM

Page 39

Mark

 

 

 

 

Description

 

 

 

 

 

 

 

Target Lock Mark

 

The target lock mark automatically tracks the fish school selected

 

 

by the operator. This function requires speed and gyrocompass inputs.

or

 

 

 

 

 

 

 

 

 

 

 

 

Net Shooting Mark

 

Press the SHOOT key at the instant you shoot the net to display the

 

 

net shooting mark on the display. The net shooting mark is drawn

Net Shooting Data

 

at own ship’s position the moment the key is pressed and moves on the

 

own ship’s track mark with ship’s movement. In addition to the

:

 

mark, time elapsed and *distance run (in meters) appear from the

 

time the key is pressed. The mark and its data remain on the screen

 

 

 

 

until the SHOOT key is pressed again.

 

 

 

 

 

 

 

Net Sonde Mark

These marks appear on the *ship’s track mark in order at set intervals,

 

when a net sonde is connected. In the echo sounder combination

 

mode they also appear in the echo sounder picture, showing depth of

(10 pts. max)

the net sonde transmitters with bars extending vertically from the marks.

 

 

 

 

 

E/S Picture Advance

Picture advance on the echo sounder combination mode automatically

Range Data

changes to ship’s speed dependent (advance) rate from the moment

 

the SHOOT key is pressed, provided there is speed log input. The

z , / /

E/S picture advance range data shows the distance between the right

 

and left edges of the echo sounder picture window in the ship’s speed

 

dependent advance. Since the net length plus wire length set on the

 

DATA SET menu is used as this distance data, the echograms

 

obtained during casting the net are displayed just across the E/S

 

window. Set net length and wire length on NET SONDE in the DATA

 

SET menu.

 

 

 

 

 

 

 

 

 

Control Setting

 

When the switches listed below are operated the new setting is noted

 

 

at the top of the screen in larger characters for five seconds. The auto

 

 

tilt width and auto scan width also appear upon turning on the AUTO

 

 

TILT and AUTO SCAN functions.

 

 

 

 

 

 

 

 

 

Control, Display

Control, Display

 

 

 

RANGE R

 

AUTO TILT

±

 

 

 

TILT

T

°

AUTO SCAN

±

 

 

 

GAIN

G .

 

BRILL

 

 

 

 

TVG TVG .

 

DIM

 

 

 

 

TX

TX .

 

 

 

 

 

 

 

 

 

 

 

 

Color Bar

 

The 16-color bar appears at the right-hand edge in the echo sounder

 

 

and history displays.

 

 

 

 

 

 

E/S Range Scale

 

The range scale for the echo sounder picture appears in the echo

 

 

sounder combination mode. You can display it on the right or left

 

 

side of the screen by selecting ES/NET REC on the INIT SET/TEST

 

 

menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

4-7

Image 39
Contents Color Scanning Sonar 00080818600 Safety Instructions Do not use the equipment for other than its intended purpose Table of Contents Vertical Scanning Display Self Tests This page is intentionally left blank Features ForewordWord to CSH-23F/24F Owners Standard Option System ConfigurationControl Description Control Layout on Display Unit and Remote Control BoxMain panel control description Main PanelGain NORM, E/S, HistRECALL, Memo RangeControl Function Sub PanelSub Panel 2 data setting window 2AGC SignalAGC ProcessSonrbeam AlarmSonar UP/TM+ + Remote Control BoxLowering the Transducer Turning the Power On/OffAdjusting Screen Brilliance, Control Panel Backlighting Operational OverviewSelecting a Display Mode ModeDescription Setting the Tilt Angle Selecting a Display RangeSeabed echo and tilt angle Points to consider How to discriminate fish echoes from the seabedTilt angle and sea surface reflections Tilt angle for surface fishTilt angle and beam coverage Suitable tilt angleMeasuring Range and Bearing to a Target Adjusting the GainPage Fine Tuning the Picture How to adjust TVGEliminating Unwanted Feeble Echoes Page Suppressing Seabed Tail AGC data setting window SIGNAL, SignalPulselength data setting window TVGTX, PL 2AGC data setting window SIGNAL, Signal ProcessData setting window TVGTX, Output Rejecting Sonar Interference and NoiseIdentifying noise source Cycle Changing Tx cycle data setting window TvgtxMenu Application Adjusting BeamwidthSetting F-shift data setting window Sonrbeam Noise limiter data setting window SIGNAL, SignalMarks, Data and Display Mode Normal display modeMarks and Data Echo sounder combination display Normal display mode w/textPermanently Displayed Marks and Data History displayMark/Data Description Erasable Marks and Data Bearing marker Mark Description Range R Auto Tilt Auto Scan Gain Brill TVG TVG DIM This page is intentionally left blank Menu How to open Menu OverviewUser Menu Operation User Menu Hist DSP/GRPH Menu screen location and display modeMenu Menu Item Description User Menu DescriptionSave Picture Current VECSystem Menu Description FAR TVGTM DSP BRG Readout Data DisplayMark Size Interlock DefaultsES/NET REC Hist DisplayColor Curve Data SET Menu DescriptionChange Color NET Plot Corr NET ShootPlan NET SondeInit SET/TEST Menu Description Echo Test Menu DescriptionProgramming the Function Keys Function KeysReplaying a Function Key Function Key Fine TuningReplaying Function Key Settings from a Memory Card Saving Function Key Settings to a Memory CardThis page is intentionally left blank Finding Fish School Center Advanced Level OperationTracking a fish school Tracking a Fish School target lockChoosing target lock mode Target lock mark appearanceErasing target lock mark Target lock and tilt angle Tracking target lock markSystem Menu Target Lock Setting target lock conditionsDescription of target lock items Detecting Fish Schools Aurally How to set the fish alarm zone Fish AlarmRelocating Fish School for Easy Observation How to relocate fish schoolsEstimate marks and their data Comparing of Fish School ConcentrationMeasuring Fish School Speed How to measure fish speed10 Event marks Event MarkErasing an event mark Entering an event mark12 True motion display True Motion Display13 Net location mark Plotting Net Location Mark14 Net behavior Observing Net BehaviorNo. Display Information Applications Target Slice DisplayThis page is intentionally left blank Vertical Scanning Display Using Vertical Scanning DisplayApplication to Bonito and Tuna Fishing Display IndicationsSearching Approaching TrackingCatching CatchingPort/Starboard display PORT/STARBOARD, Horizontal Slice DisplaysHorizontal slice display Horizontal slice displayInitializing Memory Cards Memory Card OperationsSaving the Picture Transferring Echo Data from Internal Memory to Memory CardData to Save Saving Method Saving to Transferring net shooting data to memory card Net shooting data contentsSaving Net Shooting Data How net shooting data is savedReplaying Saved Data Deleting Memory Card ContentsTurning marks on/off through the data setting window Turning MARKS, Data ON/OFFTurning marks on/off through the user menu This page is intentionally left blank Seabed Echoes Interpreting the DisplayMidwater, bottom fish Tilt angle 30 or more Fish SchoolsWake Sea Surface ReflectionsNoise and Interference False Echo by SidelobeUnretracted Transducer Warning Overvoltage WarningHow to manually raise the transducer Opening the Self Test Menu Self TestsSelf Test Description Single testContinuous test Color test Panel testSIO test Gray testInterface unit CS-120A, cover opened Interface Unit CS-120A Self TestThis page is intentionally left blank Selection of Data at Interface Unit CS-120A Input Data SelectionHow to set net sonde transmitter distances Setting Distances Between Net Sonde TransmittersDisplay Unit Maintenance MaintenanceZinc block near the transducer must be replaced yearly Hull Unit MaintenanceUser Menu Menu TreeData SET Menu Init SET/TEST Menu System Menu Previous This page is intentionally left blank SP-1 SpecificationsSP-2 DisplaySP-3 Hull UnitThis page is intentionally left blank 12-2 IndexIN-2