SPEED ALARM MESSAGE: Turn on (default setting) to display speed alarm message and sound the audio alarm when ship’s speed exceeds allowable speed for a given transducer operation. The audio alarm can be silenced with the [R/B] key.

[] pressed to lower transducer

 

Speed above 15 kts

Message 1 appears. Reduce speed below 15 kts to restore

 

 

normal operation.

 

 

 

 

 

 

 

 

 

Transducer being lowered

 

 

 

 

 

 

Speed over 15 kts

Message 1 appears and lowering continues.

Transducer lowered

 

Speed above 20 kts

Message 2 appears accompanied with the aural alarm. Reduce

 

 

the speed below 20 kts to restore normal operation.

 

 

 

 

 

 

 

 

 

[] pressed to raise transducer

 

 

 

 

Message 1 appears accompanied with the aural alarm.

 

 

Speed above 15 kts

Transducer is not raised. Reduce the speed below 15 kts to

 

 

erase the message and restore normal operation. Then, press []

 

 

 

 

 

 

again to raise the transducer.

 

 

 

 

 

 

Transducer being raised

 

 

 

 

 

 

Speed above 15 kts

Message 1 appears and raising continues. Reduce the speed below 15 kts to erase the message and restore normal operation.

SHIPS SPEED EXCEEDS 15 kt.

(SLOW DOWN UNDER 15 kt WHEN MOVING TRANSDUCER UNIT.)

PRESS R/B KEY TO SILENCE ALARM.

TRANSDUCER REMAINS LOWERED.

(REDUCE SHIP'S SPEED AND PRESS

TO RETRACT IT.)

PRESS R/B KEY TO SILENCE ALARM.

Message 1

Message 2

SWEEP INDICATOR: Shows train position in the horizontal mode and tilt angle in the vertical fan mode, with a line or a dot. (See the illustration on page 2-2 and 3-2.)

SOUNDOME SER. NO.: Set according to serial no. of soundome. Note that the setting is not cleared when default settings are restored.

5-13

Image 93
Contents Color LCD Searchlight Sonar 00080894802 Safety Instructions TFT LCD Table of Contents Menu Operation Foreword FeaturesUsage Precautions System Configuration Viii Control Description Operational OverviewRemote controller Remote ControllerTurning the Power On/Off Power onPower off Raising, Lowering the Transducer Lowering the transducerRaising the transducer Brilliance, panel dimmer dialog box Adjusting Screen Brilliance, Panel DimmerHorizontal Expanded Horizontal Selecting a DisplayBasic Menu Operation Adjusting the GainDialog box for deleting track Operational Overview Horizontal ModeColor Typical Horizontal Mode DisplaySelecting the Range One-touch selection of 360 sector Selecting Sector WidthSelecting the Tilt Angle Selecting Train CenterBottom echo and tilt angle How to discriminate fish echoes from the bottomCase1 Tilt angle 30 to Case2 Tilt angle 10 toPoints to consider Tilt angle for surface fishTilt angle and beam coverage Suitable tilt angleFinding Echo Position with the Cursor Selecting the Training SpeedInscribing the event marker Event MarkerDeleting all event markers Depth and Horizontal Range MarkersSuppressing bottom and surface reflections Adjusting the PictureDisplaying weak echoes clearly Suppressing bottom tailTo adjust TVG Erasing weak echoes Train center direction Position after expansion Remarks Enlarging fish echoes expand horizontal displaySetting target lock mode Manual reserve modeTarget Lock To use the position mode Position modeAutomatic echo tracking mode Echo modeManual echo tracking mode Horizontal menu description Horizontal Menu OverviewLOG Interpreting the Horizontal Display How the horizontal mode picture is paintedBottom echoes Sample echo displaysBottom Fish schoolsWake Sea surface reflectionsNoise and interference Sidelobe echo false echoHorizontal/history display Combination display examples28 Horizontal/Video Plotter display Horizontal/video plotter displayPress the key to display the horizontal/strata display Horizontal/strata displayFlat bottom and strata display Color bar for the strata display31 Projection in fore direction and strata display Projection in fore direction and strata displayVertical FAN Mode AFT Typical Vertical Fan Mode DisplayRange concept Default vertical fan mode range settings Train indicator One-touch selection of 180 sector Selecting Display SectorAutomatic shifting of own ship position Selecting Sector CenterNAV 11 How to inscribe, delete the event markers 12 Depth and horizontal range markers 13 Vert menu 14 Examples of proper and improper TVG Suppressing noise and interferenceVertical menu description Vertical Menu OverviewInterpreting the Vertical Fan Display How the vertical fan mode picture is paintedPort-starboard picture bottom When ship passes over fish schoolsFalse echo Display of net haulingTrain control Horizontal/vertical fan displaySector control This page intentionally left blank Event Menu Echo Sounder ModePress the key to display the echo sounder picture Typical Echo Sounder DisplayRange concept Default echo sounder mode range settings Train Direction Selecting Tilt AngleSelecting Picture Advance Speed Measuring Range by Cursor How to measure range with the cursorHow to inscribe, delete the event markers Range marker Range MarkerES menu A-scope display Finding echo strength A-scope displayEcho sounder menu description Echo Sounder Menu OverviewGeneral use This page intentionally left blank COM1 Menu Menu Operation1 COM1 menu description COM2 Menu Displaying the COM2 menu2 COM2 menu description Selecting short-cut or preset Short-cut Menu, Preset MenuSystem menu Activating custom mode Preset keyActivating a short-cut key Short-cut keyVertical Search Function SYS Menu System SettingSystem Setting 1 menu description System Setting 1 menu10 ETA marker Default Setting YES System Setting 2 menu descriptionTransducer being lowered 12 Factory Setting menu 13 Range-sonar mode menu Sonar horizontal mode range settings14 Range-ver mode menu Vertical fan mode range settings15 Range-E/S mode menu Echo sounder mode range settings16 Range-track mode menu Track range settings17 Color palette Color paletteSystem backup Loading backup dataLanguage Demonstration mode Transducer frequency adjustment23 Default menu Restoring all default settingsMAINTENANCE, Troubleshooting Preventive MaintenanceCleaning the Equipment Hull Unit Maintenance LubricationManually raising, lowering transducer Fuse Replacement Transducer MaintenanceSymptom Check, Remedy TroubleshootingMessage Meaning, Remedy Hull Unit Error MessagesLED Exit DiagnosticsPage Test pattern Test PatternScope OFF, on Menu TreeFrom Previous Specifications of 10.4 Inch Color LCD Searchlight Sonar Transceiver Unit Interface This page is intentionally left blank AGC IndexIN-2