POLAR
PATTERN
PHASE COHERENT
CARDIOID® MICROPHONE
PCC®-170SWO
The Crown®
The user can turn the mic on and off by press- ing a membrane switch on the mic. A pair
of extra leads in the mic cable allow isolated remote sensing of the microphone switch clo- sure. In a typical
Features |
|
| |
• Ideal for distance learning applications | • | ||
• | Programmable on/off switch | • | pickup of |
• | Extra leads in mic cable allow remote | ||
| sensing of mic switch closure | • | Adjustable |
The mic includes a
The membrane switch can be configured for touch on/off, momentary on, or momentary off operation. This configuration is set by a bot-
The mic can be set to be always on. In this mode, the switch only activates the remote sensing and LED. This is useful when using an external gated mixer (automatic mixer).
Remote sensing is done by a patented opto- coupled MOS switching circuit. At the remote- sensing leads, the resistance goes low when the mic is on. The microphone is attenuated 70 dB when the switch is off.
How to Set the Bass Tilt Switch
On the bottom of the microphone is a BASS- TILT switch with three positions: FLAT, CUT, and BOOST. It adjusts the
•The FLAT position provides a flat
•The CUT position rolls off the bass, useful in noisy or boomy surroundings.
•The BOOST position boosts the bass for a more natural sound when the mic is used on a small surface such as a lectern.
You can also adjust the
How to Configure the Membrane Switch
The membrane switch can be programmed to work three ways:
1.Touch on/off. Touch the switch to turn on the mic; touch it again to turn off the mic.
2.Momentary on. Touch and hold the switch to momentarily turn on the mic. Release the switch to turn the mic back off.
3.Momentary off. Touch and hold the switch to momentarily turn off the mic. Release the switch to turn the mic back on. This option
Specifications
Element: Electret condenser.
Frequency response (typical): 40 Hz to 20,000 Hz at 30 degrees incidence to surface. See Fig. 1.
Polar pattern:
Impedance: 150 ohms, balanced. (Recommended load impedance 1000 ohms or greater.)
Power sensitivity:
Equivalent noise level (self noise): 22 dB SPL typical (0 dB = .0002 dyne/cm2),
S/N ratio: 72 dB at 94 dB SPL.
Maximum SPL: 120 dB SPL produces 3% THD.
Polarity: Positive pressure on the diaphragm produces positive voltage on pin 2 with respect to pin 3.
Operating voltage: Phantom power: 24 to 48 volts DC positive on pins 2 and 3 with respect to pin 1.
Current drain: 6.8 mA nominal.
Cable:
Off-attenuation: 70 dB at 1 kHz.
Maximum voltage and current which may be applied to remote sensing
Cable wiring:
Shield: Audio shield.
Green: Audio
White: Audio
Red: Remote
Black: Remote
Operating temperature range: –10° to +50° C, or +14° to +122° F.
Materials:
Finish: Satin black.
Net weight: 6 oz. (170 g).
Dimensions: See Fig. 4.
Optional accessories: Crown PH-1A phantom
power supply (one channel, battery or
*1 pascal = 10 dynes/cm2 = 10 microbars = 94 dB SPL.
Fig. 1
Frequency Response
Fig. 2
Vertical Plane Polar Response
Fig. 3
Horizontal Plane Polar Response