Linesense

With Linesense,TTX400 and controls are combined in one.The speed and ease of installation of TTX400 remains when Linesense is used. In addition, substantial energy savings up to 75% can be achieved. Linesense has been developed for industrial applications like warehouses.

Installation clicks only

1 ZTX400 MDU control unit clicks onto the trunking.

2 Movement detector clicks on the bracket.

3 ZTX400 MB-MDU bracket clicks on the trunking.

4 Telejack cables click the detector and control unit together. 5 ZTX400 CU mains connection clicks on the control unit.

TTX400

Light-line systems

ZTX400 MDU

Pre-wired Linesense unit with integrated control function

ZTX400 MB-MDU

Mounting bracket for

movement detector

LRM8117/00

Daylight linking Manual override

Movement detection

 

 

 

 

 

 

 

Switch on/off

 

 

 

 

or dim to

 

Switch on/off

 

 

10, 20, 30%

 

 

 

 

 

 

 

LRM8117/00

High-bay passive infrared movement detector Mounting height up to 15 m

 

 

Best performance

Best economy

Linesense consists of a 618 mm piece

 

 

ZTX400 MDU HFD

ZTX400 MDU HFP

of trunking, which is fully pre-equipped

 

Movement detection (detector LRM8117)

 

 

and wired to be added to the trunking.

 

Minimum light level without presence

0, 10, 20, or 30%

0

The control function is integrated into

 

Maximum number of presence detectors per control unit

4

2*

this extra unit, and can easily be clicked

 

Maximum cable length for movement detector

300 m

125 m

between the light line and the electrical

 

 

 

 

connection unit. High bay movement

 

Daylight linking (light sensor LRL8102)

 

-

detectors are connected with standard

 

Number of light sensors per control unit

1

-

RJ-12 cables and mounted at the right

 

 

 

 

location with the use of dedicated

 

Manual control

 

-

brackets. Linesense is equipped as

 

(on, off and override)

 

 

standard with a telejack splitter to

 

 

 

 

easily connect the detectors to the

 

Type of ballast

HFD***

HFP

light line.

TTX

Maximum number of ballasts per line

64

**

 

400

TTX400 system

7 wire

5 wire

 

 

 

*2 presence detectors or 3 with LED disabled

**any number of luminaires allowed by the TTX400 light line system

***HFD=HFR-DALI

Philips indoor luminaires

Light-line systems

8.39

Image 40
Contents Page Light-line systems Selection guide Light-line systems Light-line systems Maxos Maxos the multifunctional performer, in proper style Main applications RetailOffices Industry4Public spaces 4MX691 SDW-T Fast and smooth installation Resolutie te laag Maxos aluminum reflectors and optics Wide-beam light distribution D-NB/D LineBeam light distribution C-NB LightMaxos facetted reflectors and optics Beam light distribution F/F-WB/F-A systemsline Maxos trapeze reflectors and optics Emergency lighting, for TL-D onlyMaxos 4MX092 TL-D perforated trapeze reflector Maxos 4MX692 TL5 slotted trapeze reflector T-S-D/IMaxos, 4MX092 TL-D asymmetrical trapeze reflector Maxos TL-D Wing optic 4MX092 WG Wing opticLight-line systems Maxos electrical units Light-line systems Maxos standard trunking 7x1.5/7x2.5 for dimming 1-10 Separate emergency lightingMaxos projectors and HID solutions Suitable trunkingMASTERColour CDM-T / G12 / 35 W Trunking Decorative end-plates Retail e.g. food, fashionMaxos TL-D extended trunking Maxos TL-D IP64 trunking sections 58 WMaxos 4MX056 TL-D IP64 trunking section Blind cover IP64, white Gasket between trunking sectionsMaxos TL-D IP64 electrical units InductiveHigh Frequency Performer HFP Option Emergency lighting Hour EL1, 3 hours EL3Maxos TL-D IP63 closed reflector units Maxos Accessories Chain bracket, adjustable white or silverCoupling piece for trunking available in white or silver TTX400 TTX400 the value of lighting Experience of lightingLogistics Public areas TTX400 See new alternative with TMX400 C-2R onto TTX400 TL5 TL-DElectrical unit is mounted Reflector is mounted on the electrical unitPre-wired Linesense unit with integrated control function Mounting bracket for Movement detector LRM8117/00Location with the use of dedicated Standard with a telejack splitter toTTX400 aluminum reflectors TL5 TL-D Light-line systems TTX400 multi-purpose reflectors Distribution MB systemsline Light Basic reflectors TTX400 TL-D basic reflectorsGMX430 TL-D basic reflectors Light-line systems TTX400 louvers and optics GMX555 TL5 multi-purpose reflectors and GGX555 white lamella TL-D TTX400 TL-D mirror inserts TTX400 electrical units TL5 TL-D TTX400 trunking sections TTX410 optional TTX400 units for projectors Electrical unit with an integratedTTX400 TTX400/410 suspension-/mounting brackets Suspension-/mounting bracketsMounting bracket for waterproof luminaire Mounting bracket for surface mounted luminaireZTX400 coupling piece for GMX430 TL-D basic reflectors With blind cover strips.To be used TTX400 Linesense Fully assembled TTX400 Linesense unitLight-line systems TTX150 Tetrix TTX150 a simple solution TTX150 2-lamp version onlyTTX150