Owner’s Manual
3x1 Mic/Line Mixer
Impedance | 300Ω Balanced, 150Ω Unbalanced |
|
Line Output Level | 1V (0dBV) In = 2V (+6dBV), Maximum Output 6V (15dBV) | |
Controls |
|
|
Input Level Control | Qty 3, Removable Knobs with Security Covers |
|
Output Level Control | Qty 1, Removable Knob with Security Cover |
|
Mute Input 3 | Contact Closure, Removable 2 Position Captive Screw | |
| 3.5mm Spacing |
|
VOX Mute Sens | Trim Adjust for Mic Sensitivity |
|
Output Limiter | Threshold Adjust |
|
Remote Level | Control Port 10K External Pot, Removable 2 Position Captive Screw | |
| 3.5mm Spacing |
|
Dip Switch Function | • Phantom Power 24VDC, Input 1 & 2 |
|
| • Input 1 & 2, Mic/Line Select |
|
| • Input 1 & 2, 125Hz/12dB High Pass Filter |
|
| • Input 3, Mute Receive |
|
| • Remote Level Assign, Mix or Input 3 |
|
Indicators |
|
|
Input Signal | Green, 25mV On Threshold |
|
Input Peak | Red, |
|
Limiter | Red, Limiter Activation |
|
Power | Blue |
|
Electrical |
|
|
Frequency Response | 20Hz - 20kHz (±1dB) |
|
THD | .06% & 1kHz |
|
Signal to Noise | Line to Line: 85dBV |
|
| Mic to Line: 78dBV |
|
Output Limiter | Threshold Adjust 50mV Mimimum Output to No Limit | |
Mounting |
|
|
Velcro™ | Industrial Grade, Included |
|
Brackets | Qty 2, Included |
|
Optional 1 RU Rack Mount Panel (Supports 4 TSD Units) | ||
Cable Retainer | Qty 2, Included |
|
Power Requirements |
|
|
Voltage | 24VDC |
|
Power Consumption | 60mA |
|
Power Consumption | 1.4W |
|
Dimensions | H 1.5" (39mm) x W 4" (101mm) x D 2.75" (70mm) |
|
Weight | 6oz, .165kg |
|
Accessories |
|
|
TSD 24VDC Power Supplies |
|
|
|
| |
Safety and Certifications |
|
|
External Power Supply | cUL, CE, RoHS, TUV |
|
|
| |
| 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. | |
| Telephone: 800.876.3333 • Fax: 800.765.3435 | |
| – 7 – | AtlasSound.com |
|
|
|
Specifications are subject to change without notice.