4.OPERATION

Control Panel Operation

Configuration (DMX)

Set this product in DMX mode to control it with a DMX controller.

1)Connect this product to a suitable power outlet.

2)Turn this product on.

3)Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product.

Starting Address

When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the fixture’s channels.

The Cubix™ uses one DMX channel in DMX mode, which defines the highest configurable address to 507.

If you are not familiar with the DMX protocol, you may refer to the “DMX Primer” section in the “Technical Information” chapter.

To select the starting address, do the following:

1)Set DIP [10] to the ON position.

2)Using DIP switches [1~9], select the starting address.

If you are not familiar with the procedure to configuring DIP switches, please refer to the DMX Primer section in the Technical Information chapter of this manual or visit http://www.chauvetlighting.com/chauvet-dip-switch-calculator/.

Page 8 of 18

Cubix™ User Manual (Rev. 01a)

Image 8
Contents Page Table of Contents Before YOU Begin Safety Notes Product at a GlanceIntroduction Power Linking SetupAC Power Rigging MountingOrientation Starting Address Control Panel Operation Configuration DMXOperation Configuration Standalone Modes Sound Active ModeAutomatic Mode Manual ModeMaster unit Master/Slave ModeSlave units Channel Function Value Setting Operating modeDMX Channel Assignments and Values StrobeGeneral Maintenance Technical InformationGeneral Troubleshooting Symptom Possible Cause Possible ActionReturns Procedure ClaimsContact Information World Headquarters United Kingdom & IrelandDMX Primer Fixture Linking Daisy ChainFemale Plug DMX CablingMale Plug DIP Switch Reference Guide DIP Switches = Off =Off DMX AddressTechnical Specifications