Behringer BCF2000-WH manual Midi messages

Page 17

B-CONTROL FADER BCF2000-WH

LED display of the push encoders:

OFF The LED circle remains off.

1d

(1 digit): Only one LED lights up (standard setting).

1d-

The LED circle operates similar to “1d”, but when the

 

value is 0, no LED lights up.

2d

The display of the LED circles occurs in two stages. If you

 

slowly turn the encoder from left to right, at first only one

 

LED lights up, and then the next LED lights up while the

 

previous LED goes out, and so on. This way, even the

 

slightest value changes can be accurately represented.

2d-

Just like “2d”, but when the value is 0, no LED lights up.

Bar

Bar display: when the value is changed, all LEDs light up

 

successively (for volume etc.).

Bar- Just like bar display, but when the value is 0, no LED

 

lights up.

Sprd

Spread: When the value is 0, the upper middle LED lights

 

up; when the value is increased, the LED circle gradually

 

lights up in both directions (left and right).

Pan

In the middle position (value = 64), only the upper middle

 

LED is on. With lower values, the LED circle lights up

 

toward the left; with higher values, the LED circle lights

 

up toward the right (panorama adjustment).

Qual

(Quality Q) has the opposite effect from spread: the LED

 

circle lights up gradually when you decrease the value.

 

This setting is used for indicating filter quality with

 

parametric equalizers.

Cut

Cutoff is optimal for controlling the cutoff frequency of a

 

low-pass filter, for example on a synthesizer. When the

 

value is 0, all LEDs light up. The LEDs go out successively

 

as you increase the value.

Damp

Damping: used for damping filters. When the value is 0,

 

the outer right LED lights up. If the values are increased,

 

the LED circle fans out from right to left until all LEDs

 

light up. This way, increasing damping is best represented

 

when a value goes up.

Fader functions:

Move If you move the fader by hand, it sends a new value directly. In doing so, jumps in the parameter value may occur if the current value doesn’t correspond to the fader position. This can sometimes happen because in this mode parameter feedback doesn’t cause fader movement.

P-UP Pick up: The fader ignores the parameter feedback. However, value jumps are avoided because the fader only sends values if the current value (different from the fader setting) is exceeded.

Mot

Motor: With parameter feedback, the motorized fader

 

engages automatically and always indicates the current

 

value.

Foot controller function:

Move The pedal immediately sends value changes. Value jumps may result.

P-UP Pick-Up: The foot pedal become active and sends values only if the set value is exceeded.

SWITCH-type elements:

SWITCH-type control elements have three different modes: “Toggle On”, “Toggle Off” and “Increment”. Toggle On is similar to a switching function (e.g. a light switch). Each time you press the switch, the value sent alternates between the “on” value (set by encoder 4) and the “off” value (set by encoder 5). This setting is perfect for triggering drum loops from a sampler (press once = start, press again = stop).

The Toggle Off mode corresponds to a momentary-contact button, comparable to the switch of an electric door opener. The “on” value is sent only as long as the button is pressed. After releasing the button, the “off” value is sent. Use this control type to trigger short sound FX or samples (similar to using a keyboard) by sending Note On and Offs.

The Increment option only works for buttons, and only on CC, NRPN and after touch command types. This mode lets you gradually increase the controller value with each new keystroke. Set up increment size using encoder 7. If you repeatedly press a button, the value sent will be increased each time by the preset amount selected here. If increment size is set to “10,” values 0, 10, 20, 30 ... 110, 120, 0, 10 and so on will be successively sent one after another. You can also enter negative values (e.g. -10) to achieve a gradual decrease in the value. If you use encoders 4 and 5 to delineate the lowest and the highest value that are to be sent, the values always stay within that range here as well. With this function, you have the option to use your B-CONTROL to control software buttons with more than two switch positions.

The value display activated using Push Encoder 8 is identical for switch and continuous elements. If this value display is active, the current value is indicated in the four-digit display when you actuate a control element. The display shows the preset number again as soon as you release the control element.

4.4 MIDI messages

Program Change:

With the encoders 3 and 4 you can select bank numbers. If a MIDI device contains more than 128 presets/programs, first a bank change command has to be sent. Even though this is a controller command, it has to be sent before the program change (and is therefore adjustable) since it is linked to the preset change. If the bank select message is not needed, simply select “off”.

Encoder 5 selects the program number. If the selected control element is a control dial (continuous type), the program number is directly selected when turning the dial. Pressing the switch directly selects the assigned program number. This can be useful if you always want to start from the same preset.

Control Change CC:

A control change consists of a controller number and its respective value. Encoder 3 sets the controller number. With buttons, different values can be sent when pressing and releasing (to be set with encoders 4 and 5). This function is useful if fixed parameter settings are to be sent.

With faders and control dials (continuous type), the value range can be determined by using encoders 4 (minimum value) and 5 (maximum value).

+Alternatively, you can invert the value scale by assigning 127 as the minimum value and 0 as maximum value (scale inversion). A classic application is the draw bar control of virtual or digital organs or organ expanders. If assigning controller 7 (volume) to the faders this way, the signal becomes quieter when moving up the fader. Moving down the fader is similar to moving out the draw bars, and the volume increases.

NRPN:

A NRPN is needed if none of the 127 standardized controller numbers are available for a certain function.

Encoder 3 selects the parameter number. For assigning mixer faders, we recommend the high resolution (“Absolute 14 bit”), provided that the control hardware/software supports it.

Note:

Of course, a note can only be assigned to one SWITCH element. The note is set with encoder 3. Note C3 (C key) corresponds with note number 60. Encoder 4 sets the note velocity (note volume).

4. OPERATION

17

Image 17
Contents Version 1 Control FaderControl Fader BCF2000-WH Important Safety PrecautionsControl Fader Foreword Table of ContentsIntroduction to Midi IntroductionBefore you get started System requirementsMidi connections Midi standardMidi format ExampleNrpn Control Elements and ConnectionsSysEx Dump Midi ThruSerial Number Operation USB mode U-1Operating modes USB modesYour B-CONTROL sends Midi data to the computer and receives OUT B connector. This way, you can use a master keyboard toApplications Midi Thru and forwards Midi in data unchanged. OUT B is notUSB-Mode U-4 expanded Stand Alone-Mode S-2 Stand-alone modesControl to Midi in of the second B-CONTROL. OUT a Stand Alone-Mode S-3 Stand Alone Mode S-4Second B-CONTROL needs to be connected to the Midi input Effects unit. If additional Midi devices need to be talkedProgramming Play mode menuProgramming in Edit mode Table explanation Assignment of the push encoders in Edit mode Switch typesMidi messages GS/XG Parameter Main Controls Settings in the global setup menuPush encoder allocation in global setup menu Additional functions Global Edit SetupEmulation Modes Standard Midi Controller AppendixMidi note number assignment SpecificationsWarranty Federal Communications Commission Compliance Information Control Fader BCF2000-WHControl Fader BCF2000-WH