Ashly WR-1, WR-2 Expansion Module Installation, Data In/Data Out Connection, Factory Reset Switch

Page 8

Operating Manual - ne24.24M Matrix Processor

5.8 Data In/Data Out Connection

The Data In and Out connectors are used for connecting the ne24.24M to the Ashly WR-5 active wall remote controller or RD-8C.

5.9 Factory Reset Switch

Factory reset is used to clear all user defined preset names and control values and reset them to their original factory settings. Factory reset to the ne24.24M is accomplished by pressing and holding a recessed switch on the back panel during power up. The switch is found in a small hole labelled “Reset”. There is a 10 second countdown in the front panel LED display to indicate a factory reset is about to occur. Releasing the switch or shutting off power at any time during the countdown will stop the factory reset from occurring. At the end of the countdown, the letters "Fr" flash in the display for about 20 seconds until factory reset is complete. In addition to resetting all presets to factory default, any password or security settings will be lost when a factory reset is performed.

5.10 AC Inlet and Power Switch

A detachable AC power cord is used on the ne24.24M. Since the internal universal power supply works from 90 to 240 VAC 50-60Hz, the only change necessary for use with a different AC mains connection is the appropriate AC power cord. The AC power switch is found on the back of the unit.

6. EXPANSION MODULE INSTALLATION

The Ashly ne24.24M can be ordered from the factory with expansion modules pre-installed to suit the application, or as a 4 x 4 base unit. Should the need arise to add input or output capacity at a later time, as well as logic output function, additional modules can be purchased and easily installed in the field.

There are a total of four expansion slots available, and each slot accepts either an input, an output, or a logic output module (GPO). The ne24.24M as well as Protea NE Software autodetect if a slot has been filled, and whether it is an input, output, or logic output. The software interface automatically updates to reflect the current ne24.24M expan- sion slot configuration. The logic output expansion module can be installed into any slot, however only one logic output module can be installed.

Please note that while field installation is not complicated, there is a risk of ESD (electrostatic discharge) damage to circuit board components if the board is improperly handled.

To install an additional expansion module, refer the following procedure to a qualified service technician:

1.) Remove AC power cord from back of unit and place unit on grounded work surface.

2.) Remove the seven top cover screws and remove cover. Remove expansion slot covers from back panel.

3.) Discharge any personal static by touching a grounded object. Carefully remove the new expansion card and flat cable from the ESD protective bag.

4.) Follow the instructions in the above drawing for installing expansion modules. Ashly recommends placing input expansion modules starting with EXP1, and placing output expansion modules starting from EXP 4 and working backwards. This way input and output channels are continuously numbered up from channel 1.

6.) In some cases it may be necessary to remove an existing expansion card before installing a new adjacent one. Certain motherboard flatcable headers may be inaccessible with modules installed above them.

7.) Make sure all hardware is secure, then replace top cover.

For further information on expansion module assembly or proper ESD protection, please contact the Ashly service department at 1-800-828-6308.

8

Image 8
Contents Operating Manual Ashly Audio INCTable Of Contents This Apparatus Must be Earthed Unpacking AC Power RequirementsIntroduction Front Panel Features Rear Panel Features Logic Inputs Preset RecallInput Connections Output Connections10/100 Ethernet Control Jack 0-5V Remote Level ControlExpansion Module Installation Factory Reset SwitchAC Inlet and Power Switch Data In/Data Out ConnectionHow to get Protea NE Software Protea NE SoftwareConnecting the ne24.24M to a computer using Ethernet Audio FunctionsInput Audio Functions 1a Input Mute1c Phantom Power 1e Input Delay1c Push To Talk Mic 1d Input GainOperating Manual ne24.24M Matrix Processor 1g Noise Gate 1h AutolevelerOutput Audio Functions 1i Ducker1j Matrix Routing 1k Remote Level Control2b Hpf/Lpf Crossover Butterworth2c Output Delay BesselLinkwitz-Riley 2d Output EQChannel Preset and Sub Preset File Management Other Software Functions2f Output Compressor/Limiter 2g Output MuteCopying Settings to Another Input Or Output Program UpgradeRemote Control 10.1 WR-1 Volume Control10.2 WR-2 Contact Closure Preset Recall 10.3 WR-5 Programmable Zone ControllerWR-1 Wiring Diagram CommonGPO Expansion Module Wiring Examples Troubleshooting Tips 12.1 Audio Problems12.2 RS-232 Data Communications Problems DimensionsSpecifications Warranty InformationTypical Applications Input by 8 Output Boardroom SystemLeft / Center / Right Theater System Ne24.24M Back Panel

WR-2, WR-1, WR-5 specifications

The Ashly WR series, comprising the WR-5, WR-1, and WR-2 models, is a lineup of high-performance wall controllers designed to enhance the user experience in professional audio environments. These devices are particularly useful in applications such as classrooms, conference rooms, and studios, providing intuitive control over various sound systems.

The WR-5 is the flagship model of the series, featuring a compact design that supports multiple zones. One of its standout characteristics is its ability to control various audio source devices, allowing users to select different inputs and adjust volume levels in distinct areas. The WR-5 is equipped with a large, easy-to-read LCD screen, which provides visual feedback on settings and selected configurations. Its Ethernet connectivity allows for seamless integration with compatible systems, making remote management and control straightforward.

The WR-1 is a versatile single-zone controller designed for simplicity. It features a rotary volume knob and a push-button for mute, making it an ideal choice for users who prioritize ease of use. The WR-1 can be integrated into existing setups with minimal effort, and its user-friendly interface ensures that anyone can operate the system without requiring extensive training. The unit supports audio over Ethernet, which allows for flexible placement and installation in various settings.

The WR-2 is designed for dual-zone control, offering similar features to the WR-1, but with the added benefit of managing two distinct audio zones. This model supports individual volume control for each zone, making it perfect for environments where different audio experiences are needed in separate areas. Like its counterparts, the WR-2 employs robust Ethernet connectivity, ensuring that it can communicate effectively with compatible audio systems for a cohesive overall sound experience.

All three models in the Ashly WR series are built with high-quality materials and innovative technology, ensuring durability and reliable performance. They feature intuitive layouts and responsive controls, making them suitable for a broad range of audio applications. Whether it is in a corporate environment or an educational setting, the Ashly WR series provides a sophisticated yet user-friendly solution for managing audio systems effectively.

In conclusion, the WR-5, WR-1, and WR-2 controllers are excellent options for anyone looking to streamline their audio control experience while maintaining high-quality sound management in diverse environments.