Bosch Appliances PLE-1MA030-EU, PLE-1MA060-EU, PLE-1MA120-EU manual Technical data, Electrical

Page 27

Plena Mixer Amplifier Installation and User Instructions Technical data

en 27

6Technical data

6.1Electrical

6.1.1Mains power supply

Voltage

230 VAC, ±10%, 50/60 Hz

Inrush Current PLE-1MA030-EU

4.5 A

Inrush Current PLE-1MA060-EU

5 A

Inrush Current PLE-1MA120-EU

10 A

6.1.2Power consumption

PLE-1MA030-EU

100 VA

PLE-1MA060-EU

200 VA

PLE-1MA120-EU

400 VA

6.1.3Performance

Frequency response

50 Hz to 20 kHz (+1/-3 dB @ -10 dB ref. rated output)

Distortion

<1% @ rated output power, 1 kHz Bass Control

Max -12/+12 dB (frequency is level dependent) Treble Control

Max -12/+12 dB (frequency is level dependent)

6.1.4RJ-45 input 1 x

Wall panel input

For PLE-WP3S2Z

6.1.5Mic/line input 4 x

Input 1 (Push-to-talk contact with ducking functionality)

5-pin Euro style, balanced, phantom

3-pin XLR, balanced, phantom

Input 2-4 (VOX with ducking functionality on input 2)

3-pin XLR, balanced, phantom Sensitivity

1 mV (mic); 200 mV (line) Vox sensitivity

-15 dB (attack time 20 ms; release time 4 s) Impedance

>1 kohm (mic); >5 kohm (line) S/N (flat at max volume)

63 dB (mic); >70 dB (line)

S/N (flat at min volume/muted) >75 dB

Dynamic range 100 dB

S/N (flat at max volume) >63 dB (mic); >70 dB (line)

S/N (flat at min volume/muted) >75 dB

CMRR

>40 dB (50 Hz to 20 kHz) Headroom

>25 dB Speech filter

-3 dB @ 315 Hz, high-pass, 6 dB/oct Phantom power supply

16 V via 1.2 kohm (mic)

Bosch Security Systems 2007-11 PLE-1MA030-EU, PLE-1MA060-EU, PLE-1MA120-EU en

Image 27
Contents Plena Mixer Amplifier Important safeguards Table of contents Operation Related documentation IntroductionPurpose Digital document Intended audienceConversion of units of mass Conversion tablesPlena Mixer Amplifier Contents of boxDescription Plena product rangeSchematic overview of the Plena Mixer Amplifier Controls, connectors and indicators Front panelPlena PLE-WP2Z3S wall panel Rear panel Rear panel Intentionally left blank Unpack unit InstallationInstall unit in rack optional Check settings/connectionsIntentionally left blank Connections and settings Connecting inputsPriority microphone input Additional microphones inputs 3 Secondary microphone inputEmergency inputs Connecting 100 Volt input signalConnecting emergency telephone lines Music source inputs Connecting music source inputsMaster output Connecting outputsMain output Call onlyConstant voltage loudspeakers Connecting speakersRear panel settings Unit settingsRotary controls Pin settings and labelling Operation Switch on and offSwitch on Switch offOutput controls Microphone/line controlsMusic controls Tone controlElectrical Technical dataEnvironmental MechanicalPage For more information visit