RS422x-x board configuration is:

Modem Options

Address Switches A3-A9

Address Switches A3-A9

Interrupt Jumper

LD GND Jumper

LD Jumper

DX Jumper

SX Jumper

HDX Jumper

FDX Jumper

SLOT 8 Jumper -BIAS and +BIAS

All On (RS422AT-P)

All Off (RS422I-P)

IN4

In

In

In

Out

Out

In

Out (RS422AT-P) Out (RS422I-P)

DCE Rate = 9600

Originate/Answer = Originate (CEC/IMC modem)

Originate/Answer = Answer (C3 Maestro modem)

V.32 Fast Train = Enabled

Auto Retrain = Enabled

Internal/External Clock = Internal

Dial-Up/Leased Line = Leased

2-Wire/4-Wire = 4 Wire

TX Level = (as required; use -15 dBm if line loss is 0 dB)

Dial Backup = Manual

Loop Back Time = 15 minutes

Configuration for the 3PXOCC1A board is:

Address Switches (S1)

All Off

Interrupt Jumper

IRQ4

Jumpers

JP12

JP15

Upper Position

Jumpers

JP16

JP17

Lower Position

If any other RS-422 plug-in serial board is used the following board configuration must be used:

COM Port

COM1

Port Address

3F8

Interrupt

IRQ4

See Figure 8A or the manufacturer's documentation for COM port connector pin-out details. Interconnect the

control data connections between the PC and the appropriate CEC/IMC Data Concentrator Card as required. Shielded pairs are recommended.

Remote Console Interconnections Via A 4-Wire Modem

When the C3 Maestro is installed at a remote location from the CEC/IMC, serial control data must be routed via RS-232 connections and 4-wire modems. Since the C3 Maestro requires a dedicated or continuous serial link (non- dial-up), a 4-wire leased line (or equivalent) meeting 3002 data grade specifications must be employed between the CEC/IMC and the C3 Maestro in a remote console installation.

Figure 8B shows typical control data interconnections for a remote console installation using RS-232 connections and full-duplex 4-wire modems. At the CEC/IMC Data Concentrator Card, RS-232 connections are made at J13, not J12. Observe all notes listed in the figure if wiring an installation of this type. Recommended modem settings are:

 

Dial Line = RJ11

 

Line Current Disconnect = Long

 

Long Space Disconnect = Enabled

 

V.22 Guard Tone = Disabled

MNP Options

 

MNP Protocol = Enabled

 

Auto Fallback = Enabled (or Normal)

 

Flow Control = CTS Only

 

XON/XOFF Pass Through = Enabled

 

Data Compression = Disabled

 

Inactivity Timer = Off

 

Break Control = 5

DTE Options

 

Synchronous/Asynchronous Data = Asynchronous

 

DTE Rate = 9600

 

Character Length = 8 Bits

 

Parity = None

 

Commanded Dialer = Asynchronous

 

AT Command Set = Disabled

 

DTR Control = Disabled

 

DSR = Forced High

 

DCD = Normal

 

CTS = Forced High

 

DTE Fallback = Disabled

 

Options = Retained At Disconnect

8

Image 8
Contents Table of Contents LBI-39055Table of Contents LBI-39055General − C3 Maestro Equipment InterconnectionsLogic Board Board SET-UPPersonal Computers Installation Into The PC FirmwareAudio PA Boards PLUG-IN RS-422 Board OptionalBoard Interconnecting EquipmentAudio Matrix Board Control Data Link Software Installation and SET-UPCEC/IMC Interconnections Remote Console Interconnections Via a 4-Wire Modem ∙ Modem OptionsMNP Options DTE OptionsPC-To-Audio Tower Interconnect Cable Audio LinksPersonal Computer − CEC/IMC-To-C3 Maestro Interconnections Co-Located LBI-39055 Dispatcher Keyboard Standard PC KeyboardVideo Display Monitor Desk Mic if usedBoom/Gooseneck PTT and Monitor Switches if used − BOOM/GOOSENECK MIC Wiring Wire Color DB-9 PIN NumberHeadset Jacks if used Boom/Gooseneck Mic if usedSpeakers if used Footswitches if usedVolume Controller Box if used Relay Outputs if used Pager Input if usedRecorder Outputs if used Call Director if equipped Equipment Room GroundingConsole-to-CEC/IMC Audio Interconnections Console-to-Call Director Interconnections− I/O BOARD-TO-CALL Director Signal Descriptions Type Input OutputPOWER-UP Procedure Software Installation SET-UP ProcedureAC Power and UPS Equipment PC Cmos SET-UP ProgramEditor Program Software Installation and UpgradesFile Directories and Contents Running the C3 Maestro Application Program System Manager Database Uploads Console User Profile ConfigurationDatabase Initialization System Tests LOW-LEVEL TestsSend Line B Input Audio to Speaker B Send Mic Audio To Line a & Line B OutputsCompletion Test Audio PA Board #2 if installedHIGH-LEVEL Tests