Ericsson LBI-39055 manual Database Initialization, Console User Profile Configuration

Page 21

LBI-39055

must be initialized as described in the following section before dispatch operations can be performed.

DATABASE INITIALIZATION

When the console initializes from a cold start, all of the following sections should be performed to insure proper

operation. All console databases are initialized via commands from the CEC/IMC Manager (MOM PC). See the CEC/IMC Manager operations guide LBI-38911 (version 2.x) or LBI-39024 (version 3.x) for additional details.

Basically, except for sending console configurations, all procedures presented in this section assume all CEC/IMC console configurations are complete as described in the CEC/IMC Digital Audio Switch Installation, Set-Up And Troubleshooting maintenance manual, LBI-38938. See "STEP 6 - CONSOLE CONFIGURATION" in LBI- 38938 for details.

Console User Profile Configuration

From the CEC/IMC Manager, user profile data is sent only to the targeted console. When a target console receives user profile data from the CEC/IMC Manager it will send an acknowledgment to the CEC/IMC Manager. Send user profile data to the console as follows:

1.From the CEC/IMC Manager's "CEC/IMC MOM Options" main menu, select the "Console Configuration" option. This will display the console configuration sub-menu.

2.From this sub-menu, select the "Console User Profile" option. This will display the

"CONSOLE USER PROFILE CONFIGURATION" screen.

3.Verify the CONSOLE" " number matches the CIM's console number as defined by the CIM's DIP switches.

4.Verify the Unit" ID" number does not conflict with that of any other console or radio ID number in the system.

5.Select the correct "Setup" and then make any required modification(s) to the configuration. If required, save the new configuration.

6.Press the <F7> function key to send the Console User Profile configuration to the console.

7.When the "User Profile Successfully Written..." message is displayed, return to the CEC/IMC Manager' main menu. If an "Unable to Write User Profile..." message

appears or no message appears after ten (10) seconds, the CIM may not be properly installed and/or configured. Check Controller Board installation and DIP switch settings. A "User

Profile Successfully Written..."

message must be received before continuing with the next procedure.

System Manager Database Uploads

System Manager databases contain all system information for all defined entities (units, groups, sites). These databases can be downloaded by the console by requesting database uploads from the CEC/IMC Manager. Since this data is broadcast to all consoles in the CEC/IMC system, if possible, all consoles should be on-line when this upload occurs. This avoids having to repeat the process for other consoles at a later time.

1.From the CEC/IMC Manager's "CEC/IMC MOM Options" main menu, select the "System Manager Data" option. This will display a sub- menu.

2.Select "Upload From System Manager".

3.From the "SYSTEM MANAGER UPLOAD STATUS" screen, select <F1> then <F8> for a full unit upload. After the upload is complete, exit the screen by pressing <Esc>.

4.From the "SYSTEM MANAGER UPLOAD STATUS" screen, select <F2> then <F8> for a full group upload. After the upload is complete, exit the screen by pressing <Esc>.

5.From the "SYSTEM MANAGER UPLOAD STATUS" screen, select <F6> then <F8> for a full site upload. After the upload is complete, exit the screen by pressing <Esc>.

6.From the "System Manager Data" sub-menu, select the "Upload From MOM PC" option.

7.From the "MOM PC BASED SYSTEM MANAGER UPLOAD STATUS" screen, select <F3> then <F8> for a full conventional channel upload. After the upload is complete, exit the screen by pressing <Esc>.

8.From the "MOM PC BASED SYSTEM MANAGER UPLOAD STATUS" screen, select <F5> then <F8> for a full console upload. After the upload is complete, exit the screen by pressing <Esc>.

21

Image 21
Contents LBI-39055 Table of ContentsLBI-39055 Table of Contents− C3 Maestro Equipment Interconnections GeneralBoard SET-UP Personal ComputersLogic Board Firmware Installation Into The PCAudio PA Boards PLUG-IN RS-422 Board OptionalInterconnecting Equipment Audio Matrix BoardBoard Software Installation and SET-UP CEC/IMC InterconnectionsControl Data Link ∙ Modem Options Remote Console Interconnections Via a 4-Wire ModemMNP Options DTE OptionsAudio Links Personal ComputerPC-To-Audio Tower Interconnect Cable − CEC/IMC-To-C3 Maestro Interconnections Co-Located LBI-39055 Standard PC Keyboard Dispatcher KeyboardVideo Display Monitor Desk Mic if used− BOOM/GOOSENECK MIC Wiring Wire Color DB-9 PIN Number Boom/Gooseneck PTT and Monitor Switches if usedHeadset Jacks if used Boom/Gooseneck Mic if usedFootswitches if used Volume Controller Box if usedSpeakers if used Pager Input if used Recorder Outputs if usedRelay Outputs if used Equipment Room Grounding Call Director if equippedConsole-to-CEC/IMC Audio Interconnections Console-to-Call Director InterconnectionsInput Output − I/O BOARD-TO-CALL Director Signal Descriptions TypeSoftware Installation SET-UP Procedure POWER-UP ProcedureAC Power and UPS Equipment PC Cmos SET-UP ProgramSoftware Installation and Upgrades File Directories and ContentsEditor Program Running the C3 Maestro Application Program Console User Profile Configuration Database InitializationSystem Manager Database Uploads LOW-LEVEL Tests System TestsSend Mic Audio To Line a & Line B Outputs Send Line B Input Audio to Speaker BTest Audio PA Board #2 if installed HIGH-LEVEL TestsCompletion