Chapter 5 Setting the Pedal Functions (Pedal Assign)
Active Range
When an expression pedal or other controller that changes the value consecutively is used as the source, this sets the operational range within which the value of the setting changes. If the controller is moved outside the operational range, the value does not change, but instead stops at “minimum” or “maximum.”
(Example) Act. Range Lo: 40, Act. Range Hi: 80
Controlling Foot Volume and Pitch Shifter with an External Expression Pedal
Make the following settings to use an expression pedal connected to the SUB EXP PEDAL/SUB CTL 1,2 jack to control foot volume and pitch shifter.
* Set SYS: Sub CTL1 Func (p. 63) to “Assignable.”
1.Press [PEDAL ASSIGN].
2.Press PARAMETER [ ] [ ], to display one of the Assign On/Off screens for ASSIGN
*When the upper row of the screen indicates “OFF” (flashing), press [PEDAL ASSIGN] to set it to “ON” (lit).
maximum value Target Max
minimum value Target Min
0 | 40 | 80 | 127 |
Act. Range Act. Range
Lo Hi
3.Rotate the PATCH/VALUE dial to select the following settings:
For Foot Volume:
SUB EXP FV
For Pitch Shifter:
SUB EXP PS
Chapter 5
On
ON
Off
OFF
0 | 40 | 60 | 80 | 127 |
Act. Range Center Act. Range
Lo value Max
*When using a foot switch or other on/off switching controller as the source, leave these at “Lo: 0” and “Hi: 127.” With certain settings, the value may not change.
4.If Pitch Bend has been selected in Step 3, carry out the following.
Press
Next, press PARAMETER [ ] [ ] to display “FX Select,” then select “P.S” with the PATCH/VALUE dial.