Siemens MC35 manual Examples Call barring, At+Cpin? +Cpin Ph-Sim Puk

Page 83

AT Command Set

After the "PS" lock password was incorrectly entered three times in a row:

AT+CPIN?

 

+CPIN: PH-SIM PUK

Master Phone Code is required (8-digit code

 

 

available from the manufacturer. See Chapter

 

 

4.35.1).

 

 

AT+CPIN=12345678

Master Phone Code has been accepted. As a

 

 

result, the mobile is operational, and the "PS"

 

 

lock is totally removed. If needed, it must be set

 

 

once again.

 

 

 

Example 6

Attempt to unblock the "PS" lock using an invalid Master Phone Code: Due to

 

the timing algorithm explained in Chapter 4.35.1 the intervals between each

 

attempt are getting longer. See also AT^SPIC in Chapter 8.31.

 

 

Example 7

As an alternative to the AT+CPIN command you can use AT+CPWD. In this

 

case the following syntax shall be observed: AT+CPWD=PS,Master Phone

 

Code[,new password].

 

 

 

AT+CPWD=PS,12345678

 

Deactivates the "PS" lock.

 

Or

 

 

 

AT+CPWD=PS,12345678,3333

Deactivates the present "PS" lock

 

 

 

and sets a new "PS" lock.

 

 

 

 

4.21.3 Examples: Call barring

Please note that when you configure or query call barring without specifying any classes, the settings will refer to classes 1, 2 and 4 only (default setting).

Remember that most of the call barring types have to be subscribed to. Usually, the service is subject to a password supplied from the provider.

Example 1

When checking the status

of barring for outgoing international calls without

 

specifying classes, please note that the ME returns only the status of voice,

 

data, fax calls. The status of SMS and other classes will not be indicated.

 

at+clck=oi,2,0000

 

or without <passwd>: at+clck=oi,2

 

+CLCK: 1,1

outgoing international voice calls barred

 

+CLCK: 1,2

outgoing international data calls barred

 

+CLCK: 1,4

outgoing international fax calls barred

 

OK

 

 

 

 

Example 2

To check the call barring status of all services, you are required to enter the in-

 

teger sum referring to all classes:

 

at+clck=oi,2,0000,15

or without <passwd>: at+clck=oi,2,,15

 

 

 

 

MC35_ATC_01_V04.00

Page 83 of 238

02.04.2002

Image 83
Contents AT Command Set Copyright 04.00 02.04.2002 MC35ATC01V04.00 Released General noteContents AT Commands originating from GSM AT Commands for FAXAT commands originating from GSM 07.05 for SMS 126 Siemens defined AT commands for enhanced functions Gprs AT commands in accordance with GSM 149AT Commands for SIM Application Toolkit GSM 214 AT+CIND ATOAT+CCUG AT+CCWAAtscks MC35 Module MC35 Terminal AT command MC35 ModuleScope of the document Related documents Supported product versions and related documentsSupported character sets AT command syntaxConventions AT+IPR Using parametersCombining AT commands on the same command line Entering successive AT commands on separate lines+++ Switch from data mode or PPP online mode to command mode A/ Repeat previous command lineATA AT\Qn FlowcontrolATA Answer a call AT\Q3 RTS/CTSATD Mobile originated call to dial a number Mgsm +CME Error errATDmemn Originate call to phone number n in memory mem SIMATDSM15 TA attempts to set up an outgoing call to the stored number Str Atdi Mobile originated call to dialable Isdn number n Voice call Atdl Redial last telephone number usedAtdl ATH Disconnect existing connection ATE Enable command echoXx.yy ATI Display product identification informationATIvalue Display additional identification information Revision MC35 xx.yyConnect text ATM Set monitor speaker modeATO Switch from command mode to data mode / PPP online mode ATL Set monitor speaker loudnessATS0? ATQ Set result code presentation modeATP Select pulse dialling None22 ATS4 Set response formatting character 21 ATS3 Write command line termination character23 ATS5 Write command line editing character N0 n 24 ATS6 Set pause before blind diallingATS6? ATS7?Location ID 28 ATS18 Extended error reportATT Select tone dialling +Cause location ID reason OKValue ATV Set result code format modeWhen value =0 ATX Set Connect result code format and call monitoringATZ Set all current parameters to user defined profile 33 AT&C Set circuit Data Carrier Detect DCD function mode35 AT&F Set all current parameters to manufacturer defaults 34 AT&D Set circuit Data Terminal Ready DTR function mode36 AT&S Set circuit Data Set Ready DSR function mode Active Profile 37 AT&V Display current configuration38 AT&W Store current configuration to user defined profile 41 AT+GMM Request TA model identification 39 AT+GCAP Request complete TA capabilities list40 AT+GMI Request manufacturer identification AT+GSN=? 43 AT+GSN Request TA serial number identificationIMEIAT+GMR=? Revision xx.yy+ILLRrate 44 AT+ILRR Set TE-TA local rate reporting+ILRR value OK AT+IPR? 45 AT+IPR Set fixed local rateAT+IPR=? Rates OKRestrictions on autobauding operation Autobauding and multiplex modeAutobauding Synchronization between DTE and DCEBadlin OK Currently defined Service Class values see TIA/EIA-592-AAT+FBADLIN Bad Line Threshold Bor OK AT+FBADMUL Error Threshold MultiplierAT+FBOR Query data bit order Badmul OKId OK AT+FCLASS Fax Select, read or test service classAT+FCIG Query or set the Local polling id AT+FCQ? AT+FCQ Copy Quality CheckingAT+FCR Capability to receive AT+FCQ =?Dcc OK AT+FDCC Query or set capabilitiesAT+FDCC =? AT+FDCC?Df OK AT+FDFFC Data Compression Format ConversionAT+FDFFC=? AT+FDFFC?Cdec OK 10 AT+FDIS Query or set session parametersAT+FDIS =? AT+FDIS?AT+FDT 11 AT+FDR Begin or continue phase C data reception12 AT+FDT Data Transmission AT+FDRLid OK 15 AT+FLID Query or set the Local Id setting capabilities13 AT+FET End a page or document 14 AT+FK Kill operation, orderly FAX abortGipsy Soft Protocolstack 16 AT+FMDL identify Product Model17 AT+FMFR Request Manufacturer Identification 18 AT+FOPT Set bit order independentlyTout OK 19 AT+FPHCTO DTE Phase C Response Timeout21 AT+FRH Receive Data Using Hdlc Framing 20 AT+FREV Identify Product RevisionAT+FRM=? 24 AT+FTH Transmit Data Using Hdlc Framing22 AT+FRM Receive Data 23 AT+FRS Receive SilenceAT+FTM=? 25 AT+FTM Transmit Data26 AT+FTS Stop Transmission and Wait Vrfc 27 AT+FVRFC Vertical resolution format conversionVrfc OK AT+CACM= AT+CACM Accumulated call meter ACM reset or queryAT+CACM=? AT+CACM?+CALA time,n,type,text AT+CALA Set alarm timeAT+CALA=? AT+CALA?+CALA text Ssystart Alarm Mode +CALA textAtsbc AT command UseAT+CALA AT+CCLK+CAMM acmmax OK AT+CAMM Accumulated call meter maximum ACMmax set or query+CAOC ccm OK AT+CAOC Advice of Charge information+CAOC mode OK Name AT+CBST Select bearer service type+CBST speed,name,ce Speed+CCFC status, class1, number, type , time CRLF+CCFC .... OK AT+CCFC Call forwarding number and conditions controlAT+CCFC=? +CCFC status, class1, number, type CRLF+CCFC .... OKAt+ccfc=0,3,+493012345678,145 Examples Call forwarding+CCFC 1,2,+493012345678,145 +CCLK time AT+CCLK Real Time ClockAT+CCLK=? AT+CCLK?Index AT+CCUG Closed User GroupInfo OK +CCUG n, index,info OKAT+CCWA Call waiting +CEER location ID, reason , ssreleaseOK 10 AT+CEER Extended error reportAT+CEER=? AT+CEERFull functionality 11 AT+CFUN Set phone functionalityFun AT+CFUN=?AT+CFUN? +CFUN funAT+CFUN? RstAT+CPIN +CPIN SIM PIN OK 13 AT+CGMM Request model identification 12 AT+CGMI Request manufacturer identificationAT+CHLD=? 16 AT+CHLD Call hold and multipartyAT+CGSN=? Sn OK18 AT+CIMI Request international mobile subscriber identity 17 AT+CHUP Hang up callInd 19 AT+CIND Indicator control+CIND descr,list +CIND ind,indStat AT+CIND=Dir 20 AT+CLCC List current calls of MEAT+CLCC=? Idx+CLCK status,class1CRLF +CLCK status, class2.... OK 21 AT+CLCK Facility lockAT+CLCK=? Passwdpassword Status 0 off 1 on Examples Enabling / disabling PIN 1 authenticationExamples Phone lock AT+CPIN? AT+CPIN? +CPIN PH-SIM PUK Examples Call barringAt+clck=oi,2,0000,15 +CLCK 1,1 +CLIP number, type 22 AT+CLIP Calling line identification presentation+CLIP n, m OK +CLIP number, type,,,,CLI validity+CLIR n,m +CLVL level 24 AT+CLVL Loudspeaker volume levelAT+CLVL=? AT+CLVL?Disp 25 AT+CMER Mobile equipment event reporting+CMER mode,keyp,disp,ind,bfr KeypAT+CMEE? 26 AT+CMEE Report mobile equipment error+CIEV desc,value AT+CMEE=?+CMUT n 27 AT+CMUT Mute controlAT+CMUT=? AT+CMUT?+CMUX list of supported modes OK 28 AT+CMUX Enter multiplex modeIf error is related to ME functionality AT+CMUX=mode If error is related to ME functionalityAT+CR Restricted use of AT commands in Multiplex modeCommand Behaviour on channel Differences on channel 2+3 ATECommand Description Chapter +COPN.....OK 29 AT+COPN Read operator namesAT+COPN=? AT+COPN+COPS mode, format, oper OK 30 AT+COPS Operator selectionAT+COPS=? AT+COPS?Format OperPas 31 AT+CPAS Mobile equipment activity statusAT+CPAS=? +CPAS pas OK32 AT+CPBR Read current phonebook entries Used 33 AT+CPBS Select phonebook memory storage+CPBS storage,used,total OK StorageTlength OK 34 AT+CPBW Write phonebook entryAT+CPBW=? AT+CPBW=Code 35 AT+CPIN Enter PIN+CPIN code OK PH-NS PUK PH-NET PINPH-NET PUK PH-NS PINMC35ATC01V04.00 103 02.04.2002 What to do if PIN or password authentication fails? MC35ATC01V04.00 105 02.04.2002 Code Ready 36 AT+CPIN2 Enter PIN2+CPIN2 code OK AT+CBPS=FD Ppu Ror +CME Error incorrect password is output37 AT+CPUC Price per unit and currency table +CPUC currency, ppu OKFac 38 AT+CPWD Change passwordAT+CPWD=? +CPWD list of supported fac, pwdlengths OKAt+cpwd=fac,oldpwd AT+CPWD=PS,1111,2222 AT+CR? 39 AT+CR Service reporting control+CR mode OK AT+CR=?+CRC mode OK Lac 41 AT+CREG Network registration+CREG n,stat,lac,ci +CREG stat,lac,ci +CREG statVerx +CRLP iws,mws,T1,N2,verxIws Mws43 AT+CRSM Restricted SIM access +CSCS chset 44 AT+CSCS Set TE character set+CSCS list of supported chsets AT+CSCS?+CSNS list of supported modes +CSNS mode45 AT+CSNS Single Numbering Scheme AT+CSNS=?Rssi 46 AT+CSQ Signal qualityAT+CSQ=? +CSQ rssi, ber OK+CSSN n,mOK 47 AT+CSSN Supplementary service notificationsAT+CSSN=? AT+CSSN?+CUSD n OK 48 AT+CUSD Unstructured supplementary service dataAT+CUSD=? AT+ CUSD?Duration 49 AT+VTD=n Tone durationDuration OK Dtmf See write command51 AT+WS46 Select wireless network +CMGC mr,scts AT+CMGC Send an SMS command+CMS Error err AT+CMGC=?Dex +CMGF mode OKAT+CMGD Delete SMS message AT+CMGF Select SMS message formatAT+CMGL List SMS messages from preferred store +CMGL index,lengthCRLFpdu +CMGL index,stat,fo,ctCRLF +CMGL index,stat,fo,ct... OKMC35ATC01V04.00 130 02.04.2002 +CMGR stat,sn,mid,dcs,page,pagesCRLFdata AT+CMGR Read SMS message+CMGR stat,fo,mr,ra,tora,scts,dt,st +CMGR stat,fo,ct ,pid,mn,da,toda,length CRLFcdataMC35ATC01V04.00 132 02.04.2002 Tora +CMGS mr,ackpdu OK AT+CMGS Send SMS messageAT+CMGS=? +CMGS mr,scts OKMC35ATC01V04.00 135 02.04.2002 +CMGW index OK AT+CMGW Write SMS message to memoryAT+CMGW=? MC35ATC01V04.00 137 02.04.2002 AT+CMSS Send SMS message from storage AT+CNMA New SMS message acknowledge to ME/TE, only phase 2+ +CNMI mode,mt,bm,ds,bfr OK 10 AT+CNMI New SMS message indicationsAT+CNMI=? AT+CNMI?+CBMI mem,index Ited result code +CDS lengthCRLFpdu PDU modeEnabled or +CDS fo,mr,ra,tora,scts,dt, st Code +CDSI mem,index+CPMS used1,total1,used2,total2,used3,total3 OK +CMS ERRORerr11 AT+CPMS Preferred SMS message storage MC35ATC01V04.00 143 02.04.2002 +CSCA sca,tosca OK 12 AT+CSCA SMS service centre addressAT+CSCA=? AT+CSCA?Mids 13 AT+CSCB Select cell broadcast messages+CSCB mode,mids,dcss Dcss14 AT+CSDH Show SMS text mode parameters +CSMPfo,vp/scts,pid,dcs OK 15 AT+CSMP Set SMS text mode parametersAT+CSMP=? AT+CSMP?+CSMS mt,mo,bm OK 16 AT+CSMS Select Message Service+CSMS service,mt,mo,bm OK Service+CGACT state Commands specific to MTs supporting Gprs1 AT+CGATT Gprs attach and detach StateCid 2 AT+CGACT PDP context activate or deactivate+CGACT cid, state CRLF+CGACT cid, state +CGDATA=L2P 3 AT+CGDATA Enter data stateAT+CGDATA=? L2P4 AT+CGDCONT Define PDP Context See test commandPacket Data Protocol type is a string parameter which 5 AT+CGQMIN Quality of Service Profile Minimum acceptable Delay Class Mean Transfer Delay Percentile At+cgqmin? OK at+cgqmin=1,0 OK at+cgqmin? +CGQMIN1,0,0,0,0,0 MC35ATC01V04.00 157 02.04.2002 AT+CGQREG= 6 AT+CGQREQ Quality of Service Profile RequestedAT+CGQREG=? AT+CGQREG?Non real-time traffic, error-sensitive application that At+cgqreq? OK at+cgqreq=1,0 OK at+cgqreq? +CGQREQ1,0,0,0,0,0 MC35ATC01V04.00 161 02.04.2002 +CGSMS service 7 AT+CGSMS Select service for MO SMS messages+CGACT auth Atsgauth Set type of authentication for PPP connectionAuth Calledaddress Modem compatibility commands to MTs supporting GprsATD *99# Request Gprs service ATD *98# Request Gprs IP service +CRING Gprs PDPtype,PDPaddr RingAT+CGDCONT=1 AT+CGDCONT=1,IPAT+CGDCONT? +CGDCONT1,IP AT+CGACT=1,2 AT+CGQREQ=1,2AT+CGQREQ? AT+CGQREQ=1Using the Gprs dial command ATD AT Commands for SIM Application Toolkit GSM ATSSTA= Atssta Remote-SAT Interface ActivationATSSTA=? ATSSTA?Sstn Remote-SAT Notification ATSSTGI= Atsstgi Remote-SAT Get InformationATSSTGI=? ATSSTGI?ATSSTR= Atsstr Remote-SAT ResponseATSSTR=? ATSSTR?See Scid AT+CXXCID Display card ID identical to AtscidAT+CXXCID=? AT+CXXCIDPeriod Atmoni Monitor idle mode and dedicated modeATMONI=? Dedicated channel Atmonp Atmonp Monitor neighbour cellsATMONP=? +CCCM ccm Atsacm Advice of charge and query of ACM and ACMmaxSacm n,acm,acmmax OK AcmBcs Atsbc Battery charging / discharging and charge controlSBC bcs,bcl,mpc ATSBC?ATSBC= SBC Undervoltage Scid cid OK Atscid Display SIM card identification numberATSCID=? Scks m ATSCKS=?ATSCKS? Scks n, m OKScni id2,cs,number,type Atscni List Call Number InformationATSCNI=? Scni id1,cs,number,typeSctma m For battery accumulator temperatureFor module board temperature Sctm n, m OKAtsmso Siemens ImportantAtslcd Display Last Call Duration Atsdld Delete the last number redial memoryAtshom Display Homezone Slck status,class1CRLF Slck status, class2.... OK Atslck Facility lockATSLCK=? ATSLCK=Atsmgl Atsmgl List SMS messages from preferred storageSgmo n,mode OK Smgo modeATSMGO=? ATSMGO?ATSMGR= Atsmso Switch off mobile stationAtsmgr Read SMS message without set to REC Read ATSMGR=?SM20 n,m ATSM20 Set M20 CompatibilitySnfa atten OK Atsnfa Set or query microphone attenuationATSNFA=? ATSNFA?Brate0 to 4, sideTone of all audio modes Atsnfd Set audio parameters to manufacturer default valuesATSNFD=? ATSNFI? Atsnfi Set microphone path parametersATSNFI=? Brates OKATSNFM? Atsnfm Mute microphoneAudio programming model ATSNFM=?OutStep Atsnfo Set audio output = loudspeaker path parameterOutBbcGain outCalibrate0...outCalibrate4 outStep sideTone OutCalibrate0 ... outCalibrate4Snfs audMode OK + CME Error errorAtsnfs Select audio hardware set Brate4, side Tone Atsnfv Set loudspeaker volumeAtsnfw Write audio setting in non-volatile store Snfv outStepChar Atspbc Search the first entry in the sorted telephone bookATSPBC=? See AT+CPBS/ATSPBSSpbg list of used indexs, nlength, tlength ATSPBG=?ATSPBG= Atspbs Steps the selected phonebook alphabetically Spic counter OK Atspic Display PIN counterATSPIC=? AtspicAlphan Atsplm Read the Plmn listSplm numeric numeric1,long alphanumeric alpha1CRLF SPLM.....OKSplr index1, oper Splr index2, oper OK Atsplr Read entry from the preferred operators listATSPLR=? ATSPLR=ATSPLW= Atsplw Write an entry to the preferred operators listATSPLW=? Atspwd = Atspwd Change password for a lockATSPWD=? Spwd list of supported fac, pwdlengths OKMC35ATC01V04.00 209 02.04.2002 Da display availability Atssda Set Display AvailabilitySsda da OK ATSSYNC? Atssync Configure Sync Pin+SSYNC mode OK ATSSYNC=?LED mode Function Stcd time OK Atstcd Display Total Call DurationATSTCD=? AtstcdCode of err Meaning Summary of Errors and MessagesSummary of CME Errors related to GSM Code of err Meaning 103 Illegal MS Summary of GPRS-related CME ErrorsSummary of CMS Errors related to GSM Code of err Message How to activateSummary of Unsolicited Result Codes URC ATSCTM=1 Sysstart Sysstart CHARGE-ONLY Mode Sysstart Alarm ModeMeaning How to activate IDDescription Cause Location ID for the extended error report AT+CEERResult codes Indication Numeric MeaningNumber Description GSM release cause for L3 Radio Resource RR AT+CEERSiemens release cause for L3 Radio Resource RR AT+CEER Cause related to subscription options GSM release cause for L3 Mobility Management MM AT+CEERGSM release cause for L3 Call Control CC AT+CEER Siemens release cause for L3 Mobility Management MM AT+CEERSiemens release cause for L3 Call Control CC AT+CEER Service or option not available classGSM release cause for Supplementary Service call AT+CEER Siemens release cause for L3 Advice of Charge AOC AT+CEERGSM release cause for Session Management SM AT+CEER Return Error Problem CodesSiemens release cause for Gprs API AT+CEER Siemens release cause for Session Management SM AT+CEERSiemens release cause for Embedded Netcore AT+CEER AT command Required PIN Summary of PIN requiring AT CommandsAtssda PIN Atstcd AT command Required PINAtmonp PIN Atmoni Atsacm Execute AT commands available before entering the SIM PINAT command Test Read Atsnfs Atsnfv Atsnfw Atspic Atssync AT command Test Read Write ExecuteAT+COPS Atsnfm# code Functionality Possible responses Standard GSM service codesAbbreviations of codes and responses Additional notes on SCCFC, SCCWA, Sclck Atd*#21**25# Sccfc 0,0,7 Alphabet tables MC35ATC01V04.00 238 02.04.2002
Related manuals
Manual 65 pages 56.08 Kb

MC35 specifications

The Siemens MC35 is a compact and versatile modem designed primarily for mobile communication, data transmission, and machine-to-machine (M2M) applications. Launched in the early 2000s, it quickly became popular due to its blend of performance, reliability, and ease of integration, making it a solid choice for developers and businesses.

One of the key features of the MC35 is its support for GSM and GPRS technologies. This allows it to connect seamlessly to various networks, enabling users to transmit data at speeds that were impressive for its time. The GPRS capability can offer data rates of up to 171.2 kbps, allowing for efficient data transfer even in areas with limited connectivity.

The MC35 is designed to support both SMS and voice functionalities, making it adaptable for a range of applications. This includes remote monitoring, telemetry, and alarm signaling. The ability to send and receive SMS messages is a significant advantage for applications that require immediate alerts and notifications, enhancing its utility in security systems and industrial automation.

Furthermore, the modem is equipped with a range of interfaces, including serial communication (RS232), which makes it compatible with various hardware devices. This facilitates easy integration into existing systems, whether for industrial machinery or consumer electronics. Additionally, it features a robust software development kit (SDK), which enables developers to create custom applications tailored to their specific requirements.

Power consumption is another notable characteristic of the Siemens MC35. It is engineered to be energy-efficient, which is especially important for battery-operated devices or systems that require a prolonged operation without frequent recharging or maintenance.

In terms of physical characteristics, the MC35 is compact and lightweight, allowing it to fit into various enclosure designs without occupying much space. Its durability ensures it can perform reliably in different environments, making it suitable for outdoor and industrial applications.

To summarize, the Siemens MC35 stands out as a reliable modem with a rich feature set that includes GSM and GPRS support, SMS and voice capabilities, easy integration through various interface options, and energy-efficient operation. Its adaptability makes it a valuable tool for a wide array of communication and data transmission tasks, solidifying its place in the evolution of mobile communications technology.