Siemens MC35 10 AT+CEER Extended error report, At+Ceer=?, +CEER location ID, reason , ssreleaseOK

Page 68

AT Command Set

4.10 AT+CEER Extended error report

Test command

AT+CEER=?

Execute command

AT+CEER

Reference

GSM 07.07

Response

OK

TA returns an extended error report of the reason for the last call release and location.

Response

+CEER: <location ID>, <reason > , <ss_release>OK

Parameter

 

<location ID>

Location ID as number code (see subclause 9.1.6)

<reason>

Reason for last call release as number code (see subclause

 

9.1.6)

<ss_release>

Release cause for last Supplementary Service Call

 

(see subclause 9.1.14)

Note

AT+CEER is not available for data calls, please use ATS18=1.

Default output in the case of a no-error-situation is +CEER: 0,0,0.

MC35_ATC_01_V04.00

Page 68 of 238

02.04.2002

Image 68
Contents AT Command Set 04.00 02.04.2002 MC35ATC01V04.00 Released General note CopyrightContents AT Commands for FAX AT Commands originating from GSMAT commands originating from GSM 07.05 for SMS 126 Siemens defined AT commands for enhanced functions Gprs AT commands in accordance with GSM 149AT Commands for SIM Application Toolkit GSM 214 ATO AT+CCUGAT+CCWA AT+CINDAtscks MC35 Module MC35 Terminal AT command MC35 ModuleScope of the document Supported product versions and related documents Related documentsSupported character sets AT command syntaxConventions Using parameters Combining AT commands on the same command lineEntering successive AT commands on separate lines AT+IPRA/ Repeat previous command line +++ Switch from data mode or PPP online mode to command modeAT\Qn Flowcontrol ATA Answer a callAT\Q3 RTS/CTS ATAATD Mobile originated call to dial a number +CME Error err ATDmemn Originate call to phone number n in memory memSIM MgsmATDSM15 TA attempts to set up an outgoing call to the stored number Str Atdi Mobile originated call to dialable Isdn number n Voice call Atdl Redial last telephone number usedAtdl ATE Enable command echo ATH Disconnect existing connectionATI Display product identification information ATIvalue Display additional identification informationRevision MC35 xx.yy Xx.yyATM Set monitor speaker mode ATO Switch from command mode to data mode / PPP online modeATL Set monitor speaker loudness Connect textATQ Set result code presentation mode ATP Select pulse diallingNone ATS0?22 ATS4 Set response formatting character 21 ATS3 Write command line termination character23 ATS5 Write command line editing character 24 ATS6 Set pause before blind dialling ATS6?ATS7? N0 n28 ATS18 Extended error report ATT Select tone dialling+Cause location ID reason OK Location IDATV Set result code format mode When value =0ATX Set Connect result code format and call monitoring Value33 AT&C Set circuit Data Carrier Detect DCD function mode ATZ Set all current parameters to user defined profile34 AT&D Set circuit Data Terminal Ready DTR function mode 35 AT&F Set all current parameters to manufacturer defaults36 AT&S Set circuit Data Set Ready DSR function mode 37 AT&V Display current configuration Active Profile38 AT&W Store current configuration to user defined profile 41 AT+GMM Request TA model identification 39 AT+GCAP Request complete TA capabilities list40 AT+GMI Request manufacturer identification 43 AT+GSN Request TA serial number identificationIMEI AT+GMR=?Revision xx.yy AT+GSN=?+ILLRrate 44 AT+ILRR Set TE-TA local rate reporting+ILRR value OK 45 AT+IPR Set fixed local rate AT+IPR=?Rates OK AT+IPR?Autobauding and multiplex mode AutobaudingSynchronization between DTE and DCE Restrictions on autobauding operationBadlin OK Currently defined Service Class values see TIA/EIA-592-AAT+FBADLIN Bad Line Threshold AT+FBADMUL Error Threshold Multiplier AT+FBOR Query data bit orderBadmul OK Bor OKId OK AT+FCLASS Fax Select, read or test service classAT+FCIG Query or set the Local polling id AT+FCQ Copy Quality Checking AT+FCR Capability to receiveAT+FCQ =? AT+FCQ?AT+FDCC Query or set capabilities AT+FDCC =?AT+FDCC? Dcc OKAT+FDFFC Data Compression Format Conversion AT+FDFFC=?AT+FDFFC? Df OK10 AT+FDIS Query or set session parameters AT+FDIS =?AT+FDIS? Cdec OK11 AT+FDR Begin or continue phase C data reception 12 AT+FDT Data TransmissionAT+FDR AT+FDT15 AT+FLID Query or set the Local Id setting capabilities 13 AT+FET End a page or document14 AT+FK Kill operation, orderly FAX abort Lid OK16 AT+FMDL identify Product Model 17 AT+FMFR Request Manufacturer Identification18 AT+FOPT Set bit order independently Gipsy Soft Protocolstack19 AT+FPHCTO DTE Phase C Response Timeout 21 AT+FRH Receive Data Using Hdlc Framing20 AT+FREV Identify Product Revision Tout OK24 AT+FTH Transmit Data Using Hdlc Framing 22 AT+FRM Receive Data23 AT+FRS Receive Silence AT+FRM=?AT+FTM=? 25 AT+FTM Transmit Data26 AT+FTS Stop Transmission and Wait Vrfc 27 AT+FVRFC Vertical resolution format conversionVrfc OK AT+CACM Accumulated call meter ACM reset or query AT+CACM=?AT+CACM? AT+CACM=AT+CALA Set alarm time AT+CALA=?AT+CALA? +CALA time,n,type,textSsystart Alarm Mode +CALA text +CALA textAT command Use AT+CALAAT+CCLK AtsbcAT+CAMM Accumulated call meter maximum ACMmax set or query +CAMM acmmax OK+CAOC ccm OK AT+CAOC Advice of Charge information+CAOC mode OK AT+CBST Select bearer service type +CBST speed,name,ceSpeed NameAT+CCFC Call forwarding number and conditions control AT+CCFC=?+CCFC status, class1, number, type CRLF+CCFC .... OK +CCFC status, class1, number, type , time CRLF+CCFC .... OKExamples Call forwarding At+ccfc=0,3,+493012345678,145+CCFC 1,2,+493012345678,145 AT+CCLK Real Time Clock AT+CCLK=?AT+CCLK? +CCLK timeAT+CCUG Closed User Group Info OK+CCUG n, index,info OK IndexAT+CCWA Call waiting 10 AT+CEER Extended error report AT+CEER=?AT+CEER +CEER location ID, reason , ssreleaseOK11 AT+CFUN Set phone functionality Full functionalityAT+CFUN=? AT+CFUN?+CFUN fun FunRst AT+CFUN?AT+CPIN +CPIN SIM PIN OK 12 AT+CGMI Request manufacturer identification 13 AT+CGMM Request model identification16 AT+CHLD Call hold and multiparty AT+CGSN=?Sn OK AT+CHLD=?17 AT+CHUP Hang up call 18 AT+CIMI Request international mobile subscriber identity19 AT+CIND Indicator control +CIND descr,list+CIND ind,ind IndAT+CIND= Stat20 AT+CLCC List current calls of ME AT+CLCC=?Idx Dir+CLCK status,class1CRLF +CLCK status, class2.... OK 21 AT+CLCK Facility lockAT+CLCK=? Passwdpassword Status 0 off 1 on Examples Enabling / disabling PIN 1 authenticationExamples Phone lock AT+CPIN? Examples Call barring AT+CPIN? +CPIN PH-SIM PUKAt+clck=oi,2,0000,15 +CLCK 1,1 22 AT+CLIP Calling line identification presentation +CLIP n, m OK+CLIP number, type,,,,CLI validity +CLIP number, type+CLIR n,m 24 AT+CLVL Loudspeaker volume level AT+CLVL=?AT+CLVL? +CLVL level25 AT+CMER Mobile equipment event reporting +CMER mode,keyp,disp,ind,bfrKeyp Disp26 AT+CMEE Report mobile equipment error +CIEV desc,valueAT+CMEE=? AT+CMEE?27 AT+CMUT Mute control AT+CMUT=?AT+CMUT? +CMUT n28 AT+CMUX Enter multiplex mode If error is related to ME functionalityAT+CMUX=mode If error is related to ME functionality +CMUX list of supported modes OKRestricted use of AT commands in Multiplex mode Command Behaviour on channel Differences on channel 2+3ATE AT+CRCommand Description Chapter 29 AT+COPN Read operator names AT+COPN=?AT+COPN +COPN.....OK30 AT+COPS Operator selection AT+COPS=?AT+COPS? +COPS mode, format, oper OKOper Format31 AT+CPAS Mobile equipment activity status AT+CPAS=?+CPAS pas OK Pas32 AT+CPBR Read current phonebook entries 33 AT+CPBS Select phonebook memory storage +CPBS storage,used,total OKStorage Used34 AT+CPBW Write phonebook entry AT+CPBW=?AT+CPBW= Tlength OKCode 35 AT+CPIN Enter PIN+CPIN code OK PH-NET PIN PH-NET PUKPH-NS PIN PH-NS PUKMC35ATC01V04.00 103 02.04.2002 What to do if PIN or password authentication fails? MC35ATC01V04.00 105 02.04.2002 Code Ready 36 AT+CPIN2 Enter PIN2+CPIN2 code OK AT+CBPS=FD Ror +CME Error incorrect password is output 37 AT+CPUC Price per unit and currency table+CPUC currency, ppu OK Ppu38 AT+CPWD Change password AT+CPWD=?+CPWD list of supported fac, pwdlengths OK FacAt+cpwd=fac,oldpwd AT+CPWD=PS,1111,2222 39 AT+CR Service reporting control +CR mode OKAT+CR=? AT+CR?+CRC mode OK Lac 41 AT+CREG Network registration+CREG n,stat,lac,ci +CREG stat +CREG stat,lac,ci+CRLP iws,mws,T1,N2,verx IwsMws Verx43 AT+CRSM Restricted SIM access 44 AT+CSCS Set TE character set +CSCS list of supported chsetsAT+CSCS? +CSCS chset+CSNS mode 45 AT+CSNS Single Numbering SchemeAT+CSNS=? +CSNS list of supported modes46 AT+CSQ Signal quality AT+CSQ=?+CSQ rssi, ber OK Rssi47 AT+CSSN Supplementary service notifications AT+CSSN=?AT+CSSN? +CSSN n,mOK48 AT+CUSD Unstructured supplementary service data AT+CUSD=?AT+ CUSD? +CUSD n OKDuration 49 AT+VTD=n Tone durationDuration OK See write command Dtmf51 AT+WS46 Select wireless network AT+CMGC Send an SMS command +CMS Error errAT+CMGC=? +CMGC mr,scts+CMGF mode OK AT+CMGD Delete SMS messageAT+CMGF Select SMS message format DexAT+CMGL List SMS messages from preferred store +CMGL index,stat,fo,ctCRLF +CMGL index,stat,fo,ct... OK +CMGL index,lengthCRLFpduMC35ATC01V04.00 130 02.04.2002 AT+CMGR Read SMS message +CMGR stat,fo,mr,ra,tora,scts,dt,st+CMGR stat,fo,ct ,pid,mn,da,toda,length CRLFcdata +CMGR stat,sn,mid,dcs,page,pagesCRLFdataMC35ATC01V04.00 132 02.04.2002 Tora AT+CMGS Send SMS message AT+CMGS=?+CMGS mr,scts OK +CMGS mr,ackpdu OKMC35ATC01V04.00 135 02.04.2002 +CMGW index OK AT+CMGW Write SMS message to memoryAT+CMGW=? MC35ATC01V04.00 137 02.04.2002 AT+CMSS Send SMS message from storage AT+CNMA New SMS message acknowledge to ME/TE, only phase 2+ 10 AT+CNMI New SMS message indications AT+CNMI=?AT+CNMI? +CNMI mode,mt,bm,ds,bfr OKIted result code +CDS lengthCRLFpdu PDU mode Enabled or +CDS fo,mr,ra,tora,scts,dt, stCode +CDSI mem,index +CBMI mem,index+CPMS used1,total1,used2,total2,used3,total3 OK +CMS ERRORerr11 AT+CPMS Preferred SMS message storage MC35ATC01V04.00 143 02.04.2002 12 AT+CSCA SMS service centre address AT+CSCA=?AT+CSCA? +CSCA sca,tosca OK13 AT+CSCB Select cell broadcast messages +CSCB mode,mids,dcssDcss Mids14 AT+CSDH Show SMS text mode parameters 15 AT+CSMP Set SMS text mode parameters AT+CSMP=?AT+CSMP? +CSMPfo,vp/scts,pid,dcs OK16 AT+CSMS Select Message Service +CSMS service,mt,mo,bm OKService +CSMS mt,mo,bm OKCommands specific to MTs supporting Gprs 1 AT+CGATT Gprs attach and detachState +CGACT stateCid 2 AT+CGACT PDP context activate or deactivate+CGACT cid, state CRLF+CGACT cid, state 3 AT+CGDATA Enter data state AT+CGDATA=?L2P +CGDATA=L2PSee test command 4 AT+CGDCONT Define PDP ContextPacket Data Protocol type is a string parameter which 5 AT+CGQMIN Quality of Service Profile Minimum acceptable Delay Class Mean Transfer Delay Percentile At+cgqmin? OK at+cgqmin=1,0 OK at+cgqmin? +CGQMIN1,0,0,0,0,0 MC35ATC01V04.00 157 02.04.2002 6 AT+CGQREQ Quality of Service Profile Requested AT+CGQREG=?AT+CGQREG? AT+CGQREG=Non real-time traffic, error-sensitive application that At+cgqreq? OK at+cgqreq=1,0 OK at+cgqreq? +CGQREQ1,0,0,0,0,0 MC35ATC01V04.00 161 02.04.2002 7 AT+CGSMS Select service for MO SMS messages +CGSMS service+CGACT auth Atsgauth Set type of authentication for PPP connectionAuth Calledaddress Modem compatibility commands to MTs supporting GprsATD *99# Request Gprs service ATD *98# Request Gprs IP service Ring +CRING Gprs PDPtype,PDPaddrAT+CGDCONT=1 AT+CGDCONT=1,IPAT+CGDCONT? +CGDCONT1,IP AT+CGQREQ=1,2 AT+CGQREQ?AT+CGQREQ=1 AT+CGACT=1,2Using the Gprs dial command ATD AT Commands for SIM Application Toolkit GSM Atssta Remote-SAT Interface Activation ATSSTA=?ATSSTA? ATSSTA=Sstn Remote-SAT Notification Atsstgi Remote-SAT Get Information ATSSTGI=?ATSSTGI? ATSSTGI=Atsstr Remote-SAT Response ATSSTR=?ATSSTR? ATSSTR=AT+CXXCID Display card ID identical to Atscid AT+CXXCID=?AT+CXXCID See ScidPeriod Atmoni Monitor idle mode and dedicated modeATMONI=? Dedicated channel Atmonp Atmonp Monitor neighbour cellsATMONP=? Atsacm Advice of charge and query of ACM and ACMmax Sacm n,acm,acmmax OKAcm +CCCM ccmAtsbc Battery charging / discharging and charge control BcsSBC bcs,bcl,mpc ATSBC?ATSBC= SBC Undervoltage Scid cid OK Atscid Display SIM card identification numberATSCID=? ATSCKS=? ATSCKS?Scks n, m OK Scks mAtscni List Call Number Information ATSCNI=?Scni id1,cs,number,type Scni id2,cs,number,typeFor battery accumulator temperature For module board temperatureSctm n, m OK Sctma mSiemens Important AtsmsoAtslcd Display Last Call Duration Atsdld Delete the last number redial memoryAtshom Display Homezone Atslck Facility lock ATSLCK=?ATSLCK= Slck status,class1CRLF Slck status, class2.... OKAtsmgl List SMS messages from preferred storage AtsmglSmgo mode ATSMGO=?ATSMGO? Sgmo n,mode OKAtsmso Switch off mobile station Atsmgr Read SMS message without set to REC ReadATSMGR=? ATSMGR=ATSM20 Set M20 Compatibility SM20 n,mAtsnfa Set or query microphone attenuation ATSNFA=?ATSNFA? Snfa atten OKBrate0 to 4, sideTone of all audio modes Atsnfd Set audio parameters to manufacturer default valuesATSNFD=? Atsnfi Set microphone path parameters ATSNFI=?Brates OK ATSNFI?Atsnfm Mute microphone Audio programming modelATSNFM=? ATSNFM?Atsnfo Set audio output = loudspeaker path parameter OutBbcGain outCalibrate0...outCalibrate4 outStep sideToneOutCalibrate0 ... outCalibrate4 OutStepSnfs audMode OK + CME Error errorAtsnfs Select audio hardware set Atsnfv Set loudspeaker volume Atsnfw Write audio setting in non-volatile storeSnfv outStep Brate4, side ToneAtspbc Search the first entry in the sorted telephone book ATSPBC=?See AT+CPBS/ATSPBS CharSpbg list of used indexs, nlength, tlength ATSPBG=?ATSPBG= Atspbs Steps the selected phonebook alphabetically Atspic Display PIN counter ATSPIC=?Atspic Spic counter OKAtsplm Read the Plmn list Splm numeric numeric1,long alphanumeric alpha1CRLFSPLM.....OK AlphanAtsplr Read entry from the preferred operators list ATSPLR=?ATSPLR= Splr index1, oper Splr index2, oper OKATSPLW= Atsplw Write an entry to the preferred operators listATSPLW=? Atspwd Change password for a lock ATSPWD=?Spwd list of supported fac, pwdlengths OK Atspwd =MC35ATC01V04.00 209 02.04.2002 Da display availability Atssda Set Display AvailabilitySsda da OK Atssync Configure Sync Pin +SSYNC mode OKATSSYNC=? ATSSYNC?LED mode Function Atstcd Display Total Call Duration ATSTCD=?Atstcd Stcd time OKCode of err Meaning Summary of Errors and MessagesSummary of CME Errors related to GSM Summary of GPRS-related CME Errors Code of err Meaning 103 Illegal MSSummary of CMS Errors related to GSM Code of err Message How to activateSummary of Unsolicited Result Codes URC ATSCTM=1 Sysstart Sysstart CHARGE-ONLY Mode Sysstart Alarm ModeMeaning How to activate Cause Location ID for the extended error report AT+CEER Result codesIndication Numeric Meaning IDDescriptionNumber Description GSM release cause for L3 Radio Resource RR AT+CEERSiemens release cause for L3 Radio Resource RR AT+CEER GSM release cause for L3 Mobility Management MM AT+CEER Cause related to subscription optionsSiemens release cause for L3 Mobility Management MM AT+CEER GSM release cause for L3 Call Control CC AT+CEERService or option not available class Siemens release cause for L3 Call Control CC AT+CEERSiemens release cause for L3 Advice of Charge AOC AT+CEER GSM release cause for Supplementary Service call AT+CEERReturn Error Problem Codes GSM release cause for Session Management SM AT+CEERSiemens release cause for Session Management SM AT+CEER Siemens release cause for Gprs API AT+CEERSiemens release cause for Embedded Netcore AT+CEER Summary of PIN requiring AT Commands AT command Required PINAtssda PIN Atstcd AT command Required PINAtmonp PIN Atmoni Atsacm Execute AT commands available before entering the SIM PINAT command Test Read AT command Test Read Write Execute AT+COPSAtsnfm Atsnfs Atsnfv Atsnfw Atspic AtssyncStandard GSM service codes # code Functionality Possible responsesAbbreviations of codes and responses Additional notes on SCCFC, SCCWA, Sclck Atd*#21**25# Sccfc 0,0,7 Alphabet tables MC35ATC01V04.00 238 02.04.2002
Related manuals
Manual 65 pages 56.08 Kb

MC35 specifications

The Siemens MC35 is a compact and versatile modem designed primarily for mobile communication, data transmission, and machine-to-machine (M2M) applications. Launched in the early 2000s, it quickly became popular due to its blend of performance, reliability, and ease of integration, making it a solid choice for developers and businesses.

One of the key features of the MC35 is its support for GSM and GPRS technologies. This allows it to connect seamlessly to various networks, enabling users to transmit data at speeds that were impressive for its time. The GPRS capability can offer data rates of up to 171.2 kbps, allowing for efficient data transfer even in areas with limited connectivity.

The MC35 is designed to support both SMS and voice functionalities, making it adaptable for a range of applications. This includes remote monitoring, telemetry, and alarm signaling. The ability to send and receive SMS messages is a significant advantage for applications that require immediate alerts and notifications, enhancing its utility in security systems and industrial automation.

Furthermore, the modem is equipped with a range of interfaces, including serial communication (RS232), which makes it compatible with various hardware devices. This facilitates easy integration into existing systems, whether for industrial machinery or consumer electronics. Additionally, it features a robust software development kit (SDK), which enables developers to create custom applications tailored to their specific requirements.

Power consumption is another notable characteristic of the Siemens MC35. It is engineered to be energy-efficient, which is especially important for battery-operated devices or systems that require a prolonged operation without frequent recharging or maintenance.

In terms of physical characteristics, the MC35 is compact and lightweight, allowing it to fit into various enclosure designs without occupying much space. Its durability ensures it can perform reliably in different environments, making it suitable for outdoor and industrial applications.

To summarize, the Siemens MC35 stands out as a reliable modem with a rich feature set that includes GSM and GPRS support, SMS and voice capabilities, easy integration through various interface options, and energy-efficient operation. Its adaptability makes it a valuable tool for a wide array of communication and data transmission tasks, solidifying its place in the evolution of mobile communications technology.