Tascam CD-01U specifications Time Data, Information Return, Auto CUE Level Return

Page 18

TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

5. Return Command Detail

5-1. TIME DATA

When the Time mode is set to other than “OFF” with TIME DATA SEND SELECT command [3F], controlled device outputs the time data in specified form by TIME DATA SEND SELECT command [3F].

 

Command

88

 

 

 

 

 

Data

 

8 bytes

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

Remarks

 

 

 

Data 1

Tens digit of minutes

 

 

 

 

 

Data 2

Units digit of minutes

 

 

 

 

 

Data 3

Thousands digit of minutes

 

 

 

 

 

Data 4

Hundreds digit of minutes

 

 

 

 

 

Data 5

Tens digit of seconds

 

 

 

 

 

Data 6

Units digit of seconds

 

 

 

 

 

Data 7

Tens digit of frames

 

 

 

 

 

Data 8

Units digit of frames

 

 

 

 

5-2. INFORMATION RETURN

 

 

 

 

 

Transmitted in response to an INFORMATION REQUEST command [0F].

 

Returns the software version of the controlled device.

 

 

 

Command

8F

 

 

 

Data

 

4 bytes

 

 

 

Request command

INFORMATION REQUEST [0F]

 

 

 

 

 

 

 

 

Data 1

Tens digit of software version

 

Sample data for Data 1 - Data 4

 

Data 2

Units digit of software version

 

0100

Version 1.00

 

Data 3

1st decimal digit of software version

 

 

 

 

Data 4

Hundreds digit of software version

 

 

 

5-3. AUTO CUE LEVEL RETURN

Transmitted in response to an AUTO CUE LEVEL PRESET command [20] with the request data ([FF]) to show the currently set Auto Cue level.

Command

A0

 

Data

 

2 bytes

 

Request command AUTO CUE LEVEL PRESET [20]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

-24dB

Auto Cue detect level is set to –24dB

0

 

1

-30dB

Auto Cue detect level is set to –30dB

0

 

2

-36dB

Auto Cue detect level is set to –36dB

0

 

3

-42dB

Auto Cue detect level is set to –42dB

0

 

4

-48dB

Auto Cue detect level is set to –48dB

0

 

5

-54dB

Auto Cue detect level is set to –54dB

0

 

6

-60dB

Auto Cue detect level is set to –60dB

0

 

7

-66dB

Auto Cue detect level is set to –66dB

0

 

8

-72dB

Auto Cue detect level is set to –72dB

18

TEAC Corporation

Image 18
Contents Tascam CD-01U/CD-01UPRO Electrical Specifications Connector pin-outCommunication format RXD TXD GND Command Format Overview Machine IDList of Commands Control/Preset/Sense Command Return CommandTotal Track No. / Total Time Sense 5D Command Sequence Changed StatusInformation Request Track Skip ShuttleEject CallAuto CUE Level Preset Direct Track Search PresetDescription Remarks Data Pitch Control Data Preset Time Search PresetAuto CUE Select Fade IN/OUT Time PresetData Remarks EOM Track Time SelectTIMER/RESUME Play Select Pitch Control SelectAuto Ready Select Repeat Select Incr Play SelectFade IN/OUT Select Play Mose Sense Play Mode SelectTime Data Send Select Mecha Status SenseCurrent Track Information Sense Isrc SenseDisc Status Sense Current Track Time SenseError Sense Time Data Information ReturnAuto CUE Level Return Auto CUE Select Return Pitch Control Data ReturnFade IN/OUT Time Return EOM Track Time ReturnAuto Ready Select Return TIMER/RESUME Play Select ReturnPitch Control Select Return Repeat Select ReturnFade IN/OUT Select Return Play Mode ReturnIncr Play Select Return Time Data Send Select ReturnMecha Status Return Isrc ReturnTrack No. Return Disc Status Return Current Track Information ReturnCurrent Track Time Return Total Track No./TOTAL Time ReturnPGM Total Track No./TOTAL Time Return Error Sense RequestPower on Status Illegal StatusError Sense Return