Tascam CD-01U Time Data Send Select, Play Mode Select, Play Mose Sense, Mecha Status Sense

Page 15

TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

4-23. TIME DATA SEND SELECT

Sets the Time mode of the time data that is sent out from the controlled device automatically (without any request command).

When this command is transmitted with request data [FF], the controlled device returns the TIME DATA SEND SELECT RETURN command [BF].

When specified data includes “Without Frame” information, frame information will not shown on the

display of the controlled device.

 

 

Command

3F

 

 

Data

 

2 bytes

 

 

Return

TIME DATA SEND SELECT RETURN [BF]

 

 

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

 

0

 

0

Off

Time data (TIME DATA [88]) will not be sent

 

 

 

 

 

out from the controlled device automatically

 

0

 

1

Elapsed Time

With frame data

 

0

 

2

Remain Time

With frame data

 

0

 

4

Total Remain Time

With frame data

 

1

 

1

Elapsed Time

Without frame data

 

1

 

2

Remain Time

Without frame data

 

1

 

4

Total Remain Time

Without frame data

 

F

 

F

Time Data Send status request

Requests the Output Time Data status

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-24. PLAY MODE SELECT

Sets the Play mode.

The status of the PLAY mode can be requested using the PLAY MODE SENSE command [4E].

Command

4D

 

Data

 

2 bytes

 

Return

None

 

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

Normal Play

Sets the Play Mode to normal (continuous) play mode

0

 

1

Single Play

Sets the Play Mode to single play mode

0

 

2

Program Play

Sets the Play Mode to program play mode

0

 

3

Random Play

Sets the Play Mode to random play mode

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-25. PLAY MOSE SENSE

Requests the status of the Play mode.

The contents of the reply are described in the PLAY MODE RETURN command.

Command

4E

Data

None

Return

PLAY MODE RETURN [CE]

4-26. MECHA STATUS SENSE

Requests the status of the mechanism.

The contents of the reply are described in the MECHA STATUS RETURN command.

Command

50

Data

None

Return

MECHA STATSU RETURN [D0]

15

TEAC Corporation

Image 15
Contents Tascam CD-01U/CD-01UPRO Electrical Specifications Connector pin-outCommunication format RXD TXD GND Machine ID Command Format OverviewControl/Preset/Sense Command Return Command List of CommandsTotal Track No. / Total Time Sense 5D Changed Status Command SequenceInformation Request Call ShuttleEject Track SkipAuto CUE Level Preset Direct Track Search PresetDescription Remarks Data Time Search Preset Pitch Control Data PresetEOM Track Time Select Fade IN/OUT Time PresetData Remarks Auto CUE SelectTIMER/RESUME Play Select Pitch Control SelectAuto Ready Select Repeat Select Incr Play SelectFade IN/OUT Select Mecha Status Sense Play Mode SelectTime Data Send Select Play Mose SenseCurrent Track Time Sense Isrc SenseDisc Status Sense Current Track Information SenseError Sense Time Data Information ReturnAuto CUE Level Return EOM Track Time Return Pitch Control Data ReturnFade IN/OUT Time Return Auto CUE Select ReturnRepeat Select Return TIMER/RESUME Play Select ReturnPitch Control Select Return Auto Ready Select ReturnTime Data Send Select Return Play Mode ReturnIncr Play Select Return Fade IN/OUT Select ReturnMecha Status Return Isrc ReturnTrack No. Return Current Track Information Return Disc Status ReturnTotal Track No./TOTAL Time Return Current Track Time ReturnIllegal Status Error Sense RequestPower on Status PGM Total Track No./TOTAL Time ReturnError Sense Return