Tascam CD-01U Fade IN/OUT Time Preset, Data Remarks, Auto CUE Select, EOM Track Time Select

Page 12

TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications

4-14. FADE IN/OUT TIME PRESET

Sets the fade in and out time from 1 to 10 seconds in 1 second steps.

When this command is transmitted with request data ([00FF] or [01FF]), the controlled device returns the FADE IN/OUT TIME RETURN command [AE].

The FADE mode is turned on and off using the FADE IN/OUT SELECT command [3E].

 

Command

2E

 

 

 

Data

4 bytes

 

 

 

Return

FADE IN/OUT TIME RETURN [AE]

 

 

 

 

 

 

 

Data 1

 

Data 2

Data 3

Data 4

Remarks

0

 

0

Tens digit of Fade In time

Units digit of Fade In time

Sets the Fade In time

0

 

0

F

F

Requests the Fade In

 

 

 

 

 

time

0

 

1

Tens digit of Fade Out time

Units digit of Fade Out time

Sets the fade Out time

0

 

1

F

F

Requests the Fade

 

 

 

 

 

Out time

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

·If the specified data is out of range, the controlled device sends ILLEGAL [F2].

4-15. AUTO CUE SELECT

Turns the Auto Cue function on and off.

When this command is transmitted with request data ([FF]), the controlled device returns the AUTO CUE SELECT RETURN command [B0].

The Auto Cue level is set using the AUTO CUE LEVEL PRESET command [20].

Command

30

 

Data

 

2 bytes

 

Return

AUTO CUE SELECT RETURN [B0]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

0

 

0

AUTO CUE MODE OFF

Turns the Auto Cue function off

0

 

1

AUTO CUE MODE ON

Turns the Auto Cue function on

F

 

F

Auto Cue mode status request

Requests the Auto Cue mode status

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

4-16. EOM TRACK TIME SELECT

Sets the EOM (End of message) time.

When this command is transmitted with request data ([FF]), the controlled device returns the EOM TRACK TIME RETURN command [B2].

The EOM time should be set to 00, 05, 10, 15, 20, 25, 30, or 35.

Command

32

 

Data

 

2 bytes

 

Return

EOM TRACK TIME RETURN [B2]

 

 

 

 

 

Data 1

 

Data 2

Description

Remarks

N1

 

N2

Sec

N1: Tens digit of EOM time

 

 

 

 

N2: Units digit of EOM time

 

 

 

 

(00, 05, 10, 15, 20, 25, 30, or 35)

F

 

F

EOM time request

Requests the EOM time

·If the specified data is other than described above, the controlled device sends ILLEGAL [F2].

12

TEAC Corporation

Image 12
Contents Tascam CD-01U/CD-01UPRO Electrical Specifications Connector pin-outCommunication format RXD TXD GND Command Format Overview Machine IDList of Commands Control/Preset/Sense Command Return CommandTotal Track No. / Total Time Sense 5D Command Sequence Changed StatusInformation Request Shuttle EjectTrack Skip CallAuto CUE Level Preset Direct Track Search PresetDescription Remarks Data Pitch Control Data Preset Time Search PresetFade IN/OUT Time Preset Data RemarksAuto CUE Select EOM Track Time SelectTIMER/RESUME Play Select Pitch Control SelectAuto Ready Select Repeat Select Incr Play SelectFade IN/OUT Select Play Mode Select Time Data Send SelectPlay Mose Sense Mecha Status SenseIsrc Sense Disc Status SenseCurrent Track Information Sense Current Track Time SenseError Sense Time Data Information ReturnAuto CUE Level Return Pitch Control Data Return Fade IN/OUT Time ReturnAuto CUE Select Return EOM Track Time ReturnTIMER/RESUME Play Select Return Pitch Control Select ReturnAuto Ready Select Return Repeat Select ReturnPlay Mode Return Incr Play Select ReturnFade IN/OUT Select Return Time Data Send Select ReturnMecha Status Return Isrc ReturnTrack No. Return Disc Status Return Current Track Information ReturnCurrent Track Time Return Total Track No./TOTAL Time ReturnError Sense Request Power on StatusPGM Total Track No./TOTAL Time Return Illegal StatusError Sense Return