Operating Your Camera
COLOR CCD CAMERA User’s Manual
41
COLOR CCD CAMERA User’s Manual
40
CAM ID: Assign ID number to the camera. It is restricted available to set ID from
1 to 255.
DISP CAM ID: Displays camera ID on top left corner of the screen.
BAUD RATE :
Configure baud rate from 9600, 19200, 38400, 57600bps.
UART MODE : Configure parity bit to NONE, EVEN, or ODD. Data bit is set to 8bit,
and stop bit to 1bit. Set the UART MODE to EVEN if using the
Remote Controller.
RET PKT : Used to transfer a packet.
END
IMAGE ADJ:Includes image quality or special function
factors.
FREEZE: Use this feature to freeze capture an image.
H-REV: Use this feature to horizontally inverse the screen.
V-REV: Use this feature to vertically inverse the screen.
SHARPNESS : Increasing this value sharpens object edges. Too high of a setting,
however, produces noise and may obscure the image.
COLOR AGAIN: Adjusting this value affects the chroma level only; the burst level is
unaffected.

To finish setup menu.

RESETEXIT

To reset your camera to factory default condition.

END: evert back to the USER PRESET menu.
SPECIAL SETUP
USER PRESET OFF
PRIVACY OFF
DAY/NIGHT COLOR
SYNC INT
COMM ADJ
IMAGE ADJ
SYNC : Two synchronization modes are available INTERNAL and EXTERNAL LINE-LOCK.
In LINE-LOCK mode, it synchronizes the camera’s video out signal to the external
SYNC signal.
INT: Internal synchronization
•LL: External line-lock synchronization
· If you choose ‘LL’, you can adjust the desired phase.
Press the SET button.
· You can adjust the desired phase from 0 to 359.
For NTSC models, the line-lock mode can be used if the external SYNC signal
frequency is at 60Hz.
For PAL models, the line-lock mode can be used if the external SYNC signal
frequency is at 50Hz.
Notes
COMM ADJ:Use this feature to select communication
protocol . Position the indicator over
'COMMUNICATION' using the UP or
DOWN button.