Reference Manual

00809-0100-4665, Rev AA August 2010

Rosemount 8732

Appendix H GSD File for Rosemount 8732E Magnetic Flow Transmitter

Profibus DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page H-1

Module Related Information . . . . . . . . . . . . . . . . . . . . . . . page H-2

Extended Diagnostic Bytes - Manufacturer Specific . . . . page H-3

Description of the module assignment . . . . . . . . . . . . . . page H-4

PROFIBUS DP

GSD Revision

1

Vendor Name

Rosemount

Model Name

Rosemount Flow 8732E

Revision

V1.00

Ident Number

0x0C15

Protocol Ident

0; 0 = Profibus-DP

Station Type

0 = DP-Slave

FMS supp

0; 0 = Only DP Slave

Hardware Release

V1.0

Bitmap Device

V1.0

31.25 supp

RFD0C15

45.45 supp

1

93.75 supp

1

MaxTsdr 31.25

1

MaxTsdr 45.45

100

MaxTsdr 93.75

250

Redundancy

1000

Repeater Ctrl_Sig

0; No Redundancy supported

24V Pins

Not Connected

Implementation Type

Custom SW/HW

BASIC DP SLAVE RELATED KEYWORDS

Freeze Mode supp

0

Sync Mode supp

0

Auto Baud supp

0

Set Slave Add supp

1

Min Slave Intervall

250; in 100 us

www.rosemount.com

Page 163
Image 163
Emerson Rosemount 8732 manual Profibus DP, Basic DP Slave Related Keywords