Reference Manual
Rosemount 8732
DSP Software Rev
This function displays the software revision number of the transmitter.
Construction Materials
Construction materials contain information about the sensor that is connected to the transmitter. This information is configured into the transmitter for later reference. This information can be helpful when calling the factory for support.
Flange Type
Flange type enables you to select the flange type for your magnetic transmitter system. This variable only needs to be changed if you have changed your sensor. Options for this value are:
• ANSI 150 | • PN 10 |
|
|
• ANSI 300 | • PN 16 |
|
|
• ANSI 600 | • PN 25 |
|
|
• ANSI 900 | • PN 40 |
|
|
• ANSI 1500 | • PN 64 |
|
|
• ANSI 2500 | • Other |
|
|
• Wafer |
|
|
|
Flange Material
Flange material enables you to select the flange material for your magnetic transmitter system. This variable only needs to be changed if you have changed your sensor. Options for this value are:
•Carbon Steel
•304L Stainless Steel
•316L Stainless Steel
•Wafer
•Other
Electrode Type
Electrode type enables you to select the electrode type for your magnetic transmitter system. This variable only needs to be changed if you have replaced electrodes or if you have replaced your sensor. Options for this value are:
•Standard
•Std & Ground
•Bullet
•Other