Reference Manual

00809-0100-4665, Rev AA August 2010

Rosemount 8732

DSP Software Rev

This function displays the software revision number of the transmitter.

Construction Materials

Construction materials contain information about the sensor that is connected to the transmitter. This information is configured into the transmitter for later reference. This information can be helpful when calling the factory for support.

Flange Type

Flange type enables you to select the flange type for your magnetic transmitter system. This variable only needs to be changed if you have changed your sensor. Options for this value are:

• ANSI 150

• PN 10

 

 

• ANSI 300

• PN 16

 

 

• ANSI 600

• PN 25

 

 

• ANSI 900

• PN 40

 

 

• ANSI 1500

• PN 64

 

 

• ANSI 2500

• Other

 

 

• Wafer

 

 

 

Flange Material

Flange material enables you to select the flange material for your magnetic transmitter system. This variable only needs to be changed if you have changed your sensor. Options for this value are:

Carbon Steel

304L Stainless Steel

316L Stainless Steel

Wafer

Other

Electrode Type

Electrode type enables you to select the electrode type for your magnetic transmitter system. This variable only needs to be changed if you have replaced electrodes or if you have replaced your sensor. Options for this value are:

Standard

Std & Ground

Bullet

Other

4-15

Page 45
Image 45
Emerson Rosemount 8732 manual DSP Software Rev, Construction Materials, Flange Type, Flange Material, Electrode Type