Rosemount 8732
Reference Manual
TAYLOR SENSORS
Series 1100 Sensor to Rosemount 8732 Transmitter
Connect coil drive and electrode cables as shown in Figure
Figure E-19. Wiring Diagram for Taylor Series 1100 Sensors and Rosemount 8732
Table E-20. Taylor Series 1100 Sensor Wiring Connections
TAYLOR SERIES 1100 | ROSEMOUNT 8732 | ||
SENSOR | |||
TRANSMITTER | |||
|
| ||
Electrode Connections |
| ||
C |
|
| |
L |
|
| |
A |
|
| |
R |
|
| |
L N G 1 2 3 4 |
|
| |
White |
|
| |
| Black |
| |
Coil Connections | Green |
| |
|
|
Rosemount 8732 |
| Taylor Series 1100 Sensors | ||||
1 |
|
|
| Black | ||
2 |
|
|
| White | ||
|
|
|
|
|
| Green |
|
|
|
|
| ||
17 |
|
| S1 and S2 | |||
18 |
|
| E1 | |||
19 |
|
| E2 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This is a pulsed DC magnetic flowmeter.
Do not connect AC power to the sensor or to terminals 1 and 2 of the transmitter, or replacement of the electronics board will be necessary.