Rosemount 8732
Reference Manual
Index | Parameter Name | Description |
25 | LOW_FLOW_CUTOFF | When flow rate is less than this entered value, |
|
| flow rate output will be set to 0.0 flow. |
|
| See section Engineering Units for supported |
|
| unit codes. |
26 | MEASUREMENT_MODE | Mode of flow measurement, either |
|
| unidirectional or bidirectional measurement. |
27 | FLOW_DIRECTION | Please refer Profibus specifications. |
28 | ZERO_POINT | This parameter is standard PA magnetic flow |
|
| parameter. Not used within 8732E device. |
29 | ZERO_POINT_ADJUST | This parameter is standard PA magnetic flow |
|
| parameter. Not used within 8732E device. |
30 | ZERO_POINT_UNIT | This parameter is standard PA magnetic flow |
|
| parameter. Not used within 8732E device. |
31 | NOMINAL_SIZE | Pleases refer to Profibus specifications |
|
| Note: The value of the NOMINAL_SIZE |
|
| parameter is determined from the value of the |
|
| TUBE_SIZE parameter. |
32 | NOMINAL_SIZE_UNITS | Selects the unit for nominal size parameter. |
33 | VOLUME_FLOW | Please refer to Profibus specifications |
34 | VOLUME_FLOW_UNITS | Selected unit code for VOLUME_FLOW, |
|
| VOLUME_FLOW_LO_LIMIT and |
|
| VOLUME_FLOW_HI_LIMIT parameters. |
35 | VOLUME_FLOW_LO_LIMIT | Absolute value of the lower range value |
|
| (volume flow) of the sensor. – Not referred in |
|
| 8732E device for any status calculation. Used |
|
| for setting up the range for the dial on PDM |
|
| screen |
|
| VOLUME_FLOW_HI_LIMIT parameters. |
36 | VOLUME_FLOW_HI_LIMIT | Absolute value of the upper range value |
|
| (volume flow) of the sensor.- Not referred in |
|
| 8732E device for any status calculation. Used |
|
| for setting up the range for the dial on PDM |
|
| screen. |
RESERVED | Flow transducer block parameters listed in | |
|
| profile specification which are not applicable |
|
| for mag flow meter. |
57 | SAMPLING_FREQ | Pls refer Profibus specifications |
|
| Note: The value of the SAMPLING_FREQ |
|
| parameter is determined from the value of the |
|
| COIL_DRIVE_FREQ parameter. |
58 | SAMPLING_FREQ_UNITS | Selected unit code for SAMPLING_FREQ |
|
| parameter. |
Reserved by PNO | Please refer to Profibus specifications. | |
| Manufacture Specific Parameters |
|
69 | DAMPING | Damping filter value in seconds. |
70 | DENSITY_UNIT | See section Engineering Units for supported |
|
| unit codes. |
71 | DENSITY_VALUE | User entered density value to be used when |
|
| calculating flow in mass flow units. |
72 | SENSOR_CAL_NO | Sensor Calibration Number. |
73 | SENSOR_SIZE | Sensor Line Size. |
74 | COIL_DRIVE_FREQ | Coil Drive Frequency |
|
| Note: Enumerated value of this parameter |
|
| determines the floating point value of the |
|
| SAMPLING_FREQ parameter. |
75 | DIAG_SIG_POWER | Signal power at current coil drive frequency. |
76 | RESERVED | DETAILED_STATUS marked as RESERVED |
|
| for PA device. |
77 | LOI_LANG | Selects the language to be used on the local |
|
| display for status and diagnostics messages. |